Technical Data
Sup Z1 C1 Air damper weatherproof, 1430x1200
dp Air: 2 Pa
Sup Z1 C2 bag filter HE ISO Coarse 60% (G4), frame galv. steel
Filter Length: 580 mm Filter Surcafe: 20.8 m²
Air Velocity: 2.6 m/s
dP Calc: 96 Pa Energy-Class:
dP Start: 41 Pa dP End (EN13053): 150 Pa
Measures: 4x592², 2x287x592,
Sup W1 C1 RWT-EM1950x1950-1900V-020
Reference: EM1950x1950-1900V-020-2D0CI-8API-A
Wheel Type: Adsorption (Molecular Sieve) Construction: one piece
Temp outside Air: -15 °C Temp. Exhaust: 22 °C
Humidity outside Air: 90 %r.F. Humidity Exhaust: 45 %r.F.
Temp. Supply: 10.1 °C Temp out Exhaust: -8 °C
Humidity Supply: 73.3 %r.F. Humidity out Exhaust: 93.5 %r.F.
dP Supply: 152 Pa dP Exhaust: 125 Pa
Recovery Factor: 67.7 %
Total Power: 200 kW Temp. Übertragungsgrad tr.: 74.5 %
Sensible Power: 137 kW Humidity Efficiency: 72.2 %
Latent Power: 62.4 kW
Temperature outside Air = Design outdoor Temperature (Eurovent)
Leakage: Quantity and direction depending on fan configuration and possible used irrigation chamber
Please consider the leakage in the design
Aufgen. Leistung Motor: 0.4 kW Coefficient of Performance: 32
Efficiency-Class: 72.2 % Heat Recovery Class: H1
Power Cons. Due to dp: 2.16 kW
Operating Point 2:
Temp outside Air: 35 °C Temp. Exhaust: 26 °C
Humidity outside Air: 35 %r.F. Humidity Exhaust: 60 %r.F.
Temp. Supply: 28.3 °C Temp out Exhaust: 32.7 °C
Humidity Supply: 51.5 %r.F. Humidity out Exhaust: 40.6 %r.F.
dP Supply: 155 Pa dP Exhaust: 157 Pa
Total Power: -36 kW Recovery Factor: 74.6 %
Sensible Power: -36 kW Humidity Efficiency: 25.4 %
Latent Power: 0.0369 kW
Exh A1 C3 bag filter HE ISO ePM10 60% (M5), frame galv. steel
Filter Length: 600 mm Filter Surcafe: 30 m²
Air Velocity: 2.15 m/s
dP Calc: 114 Pa Energy-Class: A
dP Start: 28 Pa dP End (EN13053): 200 Pa
Measures: 4x592², 2x287x592,
Properties:
Type of HRS: rotary heat exchanger
Thermal efficiency (EN13053): 74 %
External maximum leakage rate (+400Pa / -400Pa): 0.32 % / 0.34 %
Internal maximum leakage rate (250Pa): 1%
Supply Exhaust
Air volume: 4.53 m³/s Air volume: 3.75 m³/s
∆psext: 250 Pa ∆psext: 350 Pa
Input Power: 6.61 kW Input Power: 4.25 kW
∆psint: 269 Pa ∆psint: 169 Pa
∆psadd: 397 Pa ∆psadd: 114 Pa
Velocity: 2.2 m/s Velocity: 1.8 m/s
ηstat(327/2011/EU): / Eff. Grade N 69 % ηstat(327/2011/EU): / Eff. Grade N 69 %
Filter: F9 Filter: M5
Sound power level: 53 dB(A) Sound power level: 49 dB(A)
General:
Filter warning: To fulfil the regulation 1253/2014/EU the installed filters need to be equipped with
a visual signal or an alarm in the control system which shall be activated as soon
as the filter pressure drop exceeds the maximum final pressure drop.
Thermal bypass: The thermal bypass can be realized by a stoppage of the rotary heat exchanger.
Drive: If the ventilation unit is ordered and delivered without multi-speed drive or variable
speed drive, it has to be provided with it to fulfil regulation 1253/2014/EU.
Delivery Condition
Payment Conditions
Delivery Time
2Pa0Pa
152Pa 4Pa 1Pa 114Pa 37Pa 0Pa
45kg
8kg
316kg 226kg 0kg 31kg 73kg 8kg
1364
PRALL TF
A3 A2 A1
TF PRALL TF SOND-ERH
Z1 W1 Z2 Z3 Z4
152Pa
316kg
2Pa96Pa2Pa0Pa
0Pa 1Pa
4Pa 6Pa 1Pa 114Pa
212Pa 37Pa
57Pa 0Pa 140Pa 0Pa
45kg
30kg45kg
8kg
8kg 0kg
226kg
226kg 0kg 31kg
16kg 73kg
84kg 8kg 87kg 8kg
1674
TF PRALL PRALL TF
TF SOND-ERH
Z1 A3 A2
Z2 Z3
A1 Z4
W1
Technical Data
Sup W1 C1 RWT-EM1950x1950-1900V-020
Reference: EM1950x1950-1900V-020-2D0CI-8API-A
Wheel Type: Adsorption (Molecular Sieve) Construction: one piece
Temp outside Air: 35 °C Temp. Exhaust: 26 °C
Humidity outside Air: 35 %r.F. Humidity Exhaust: 60 %r.F.
Temp. Supply: 28.8 °C Temp out Exhaust: 33.5 °C
Humidity Supply: 50.1 %r.F. Humidity out Exhaust: 38.7 %r.F.
dP Supply: 151 Pa dP Exhaust: 125 Pa
Recovery Factor: 69 %
Total Power: 33.7 kW Temp. Übertragungsgrad tr.: 74.6 %
Sensible Power: 33.7 kW Humidity Efficiency: 22.3 %
Latent Power: 0 kW
Temperature outside Air = Design outdoor Temperature (Eurovent)
Leakage: Quantity and direction depending on fan configuration and possible used irrigation chamber
Please consider the leakage in the design
Aufgen. Leistung Motor: 0.4 kW Coefficient of Performance: 32
Efficiency-Class: 72.3 % Heat Recovery Class: H1
Power Cons. Due to dp: 2.16 kW
Operating Point 2:
Temp outside Air: 35 °C Temp. Exhaust: 26 °C
Humidity outside Air: 35 %r.F. Humidity Exhaust: 60 %r.F.
Temp. Supply: 28.3 °C Temp out Exhaust: 32.7 °C
Humidity Supply: 51.5 %r.F. Humidity out Exhaust: 40.6 %r.F.
dP Supply: 155 Pa dP Exhaust: 157 Pa
Total Power: -36 kW Recovery Factor: 74.6 %
Sensible Power: -36 kW Humidity Efficiency: 25.4 %
Latent Power: 0.0369 kW
Air Density: 1,2 kg/m³, Barometric Pressure: 1013,25 hPa
SFP-Class (EnEV): under validation load conditions including bonus if heat recovery class H1 or H2