Solution:
Assuming 'mild' exposure conditions,
Design of Steel :-
For the design, the following data are available to us:
b = 1000 mm
D = 175 mm
Effective depth d = 149 mm #4
Mu = 48.5 KMm #6
A1/A6 0.450m X0.450m 2.600 m 2.600 m 2.700 m 2.700 m 0.955 m 0.212 m Ø12 @ 125 mm c/c Ø12 @ 125 mm c/c
A2/A5 0.450m X0.450m 3.100 m 3.100 m 3.200 m 3.200 m 0.655 m 0.162 m Ø12 @ 125 mm c/c Ø12 @ 125 mm c/c
A3/A4 0.450m X0.450m 3.100 m 3.100 m 3.200 m 3.200 m 0.705 m 0.212 m Ø12 @ 125 mm c/c Ø12 @ 125 mm c/c
B1/B6 0.450m X0.450m 3.100 m 3.100 m 3.200 m 3.200 m 1.105 m 0.212 m Ø12 @ 75 mm c/c Ø12 @ 75 mm c/c
B2/B5 0.450m X0.450m 3.600 m 3.600 m 3.700 m 3.700 m 0.805 m 0.212 m Ø12 @ 100 mm c/c Ø12 @ 100 mm c/c
B3/B4 0.450m X0.450m 3.650 m 3.650 m 3.750 m 3.750 m 0.805 m 0.162 m Ø12 @ 100 mm c/c Ø12 @ 100 mm c/c
C1/C6 0.450m X0.450m 3.100 m 3.100 m 3.200 m 3.200 m 1.105 m 0.262 m Ø12 @ 75 mm c/c Ø12 @ 75 mm c/c
C2/C5 0.450m X0.450m 3.650 m 3.650 m 3.750 m 3.750 m 1.305 m 0.262 m Ø12 @ 50 mm c/c Ø12 @ 50 mm c/c
C3/C4 0.450m X0.450m 3.850 m 3.850 m 3.950 m 3.950 m 1.405 m 0.162 m Ø12 @ 50 mm c/c Ø12 @ 50 mm c/c
D1/D6 0.450m X0.450m 2.650 m 2.650 m 2.750 m 2.750 m 0.855 m 0.162 m Ø12 @ 100 mm c/c Ø12 @ 100 mm c/c
D2/D5 0.450m X0.450m 3.100 m 3.100 m 3.200 m 3.200 m 1.105 m 0.262 m Ø12 @ 75 mm c/c Ø12 @ 75 mm c/c
D3/D4 0.450m X0.450m 3.400 m 3.400 m 3.500 m 3.500 m 1.205 m 0.112 m Ø12 @ 75 mm c/c Ø12 @ 75 mm c/c
Name of Size of Column
Column Reinforcement
Column (bXd)
Foundation Level to Basement Level To Ground Floor Level 1st Floor Level 2nd 2nd Floor Level 3rd 3rd Floor Level 4th 4th Floor Level 5th
Basement Level Ground Floor Level To 1st Floor Level Floor Level Floor Level Floor Level Floor Level
A1/A6 0.450m X0.450m Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 8 Nos. Bar Ø25 - 8 Nos. Bar Ø25 - 8 Nos. Bar -
A2/A5 0.450m X0.450m Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar -
A3/A4 0.450m X0.450m Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar -
B1/B6 0.450m X0.450m Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar -
B2/B5 0.450m X0.450m Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar -
B3/B4 0.450m X0.450m Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar -
Foundation Level to Foundation Level To Ground Floor Level 1st Floor Level 2nd 2nd Floor Level 3rd 3rd Floor Level 4th 4th Floor Level 5th
Basement Level Ground Floor Level To 1st Floor Level Floor Level Floor Level Floor Level Floor Level
C1/C6 0.450m X0.450m - Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar -
C2/C5 0.450m X0.450m - Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar -
C3/C4 0.450m X0.450m - Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 16 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar
D1/D6 0.450m X0.450m - Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 8 Nos. Bar Ø25 - 8 Nos. Bar -
D2/D5 0.450m X0.450m - Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 12 Nos. Bar Ø25 - 8 Nos. Bar Ø25 - 8 Nos. Bar -