An Humidity test chamber

artificially replicates the


conditions under which
machinery, materials, devices
or components might be
exposed. It is also used to
accelerate the effects of
exposure to the environment,
sometimes at conditions not
actually expected.
These conditions may include:

 extreme temperatures
 sudden and extreme temperature variations - thermal shock
 altitude
 moisture or relative humidity
 electrodynamic vibrations
 electromagnetic radiation
 Cyclic corrosion testing
 salt spray
 rain
 weathering
 exposure to sun, causing UV degradation
 vacuum
 Manufactured samples, specimens, or components are placed inside
the chamber and subjected to one or more of these environmental
parameters to determine reliability or measure after-effects such as
corrosion. In the case of machinery such as internal combustion
engines, byproducts such as emissions are monitored.
 Mechanically cooled test chambers
 Liquid nitrogen cooled test chambers
 Modular Walk-in Chambers

 An Humidity chamber can be a small room used both


to condition test specimens and to conduct the test. It
can be a smaller unit that's used for conditioning test
items. Also, some chambers are small enough to be
placed onto a universal testing machine or other test
apparatus.

 Many chambers are set at a certain set of conditions.


Others can be programmed to cycle through specified
sequences of conditions.
Humidity Chambers can simulate both
temperature and humidity. Controlled humidity
from 10% RH to 95% RH can be maintained
within the dry-bulb temperature range of +10°C
to +85°C, limited by a 6°C dew point. For lower
dew point conditions (low RH or relative
humidity at low dry-bulb temperatures), you
will need dry air purge or GN2 (gaseous
nitrogen) purge. See the humidity range chart on
the specification page of each temperature-
humidity chamber for humidity range limits
 Double walled construction with backside triple.
 3” Thick PUF Insulation ensures stable temperature with humidity &
reduced energy consumption.
 Motorized Blower at back side of the chamber develops unique air flow
system which ensures maximum uniform temperature & humidity
condition inside the chamber.Unique air flow assures quick recovery after
door openings.
 1/12 HP, TEFC , F-class insulation, Single phase, 1440 RPM, 230 Volts
 High quality U shape S.S. Tubular Heaters are used for better heating.
 Steam injection system (Non condensing type) & reservoir tank with
water level arrangement with indicator.
 Temperature Control
 Temperature Control : By means of Imported Microprocessor based auto
tuned PID controller with CE mark & dual display of set value & process
value.
 Humidity Control
 Humidity Control & Sensing : By means of Imported Microprocessor
based auto tuned PID controller with CE mark & dual display of set value
& process value with direct % RH.Direct RH electronic capacitor type
humidity sensor, avoid wick cup & water.
 Safety Features
 Additional Safety thermostat to cut of dry heater supply in case
temperature of overshoot.
 Float switch to cutoff the wet heater supply in case of low water level.
Audio & Visual alarm.
 Compressor ON delay timer (2 min.) to safe guard the compressor.
 In built over load protector provided for hermetically sealed compressor.
 50 mm validation port hole with silicon rubber seal to insert sensors for
validation.
 Full view observation Acrylic door with gasket to observe sample inside
the chamber.
 Interior illumination for Working area
 Specially designed stainless steel rod trays ensure uniform temperature
distribution.
 Data Logger
 CFR 21 part 11 compliance software for data
logger
 Data scanner complete with sensor
 SMS Mobile alert system
 Door access security system
 Safety digital temperature controller
 Timer
Does your application temperature lie between 8 °C above
room temperature and 90°C, with controllable humidity? Then the
Memmert humidity chamber HCP is unbeatable in price,
performance and comfort.
The almost unlimited programming possibilities of
temperature profiles make ideal environmental conditions for the
load possible.
 Temperature range up to +90 °C (without humidity up to +160 °C)
 3 model sizes (108 to 246 litres volume)
 State-of-the-art control technology
 an active humidity control system is integrated
 double doors: no contamination and drops or rises in temperature,
and at the same time an optimal view of the sensitive load
through wide-area interior glass doors
 the inner chamber, including the ventilation system, the water
trays and all sensors, can be sterilised at 160 °C in a 4 hour
programme
 heating concept specifically adapted for a precise
and homogenous temperature control
 alarm functions, three-fold overtemperature
protection and simultaneous display of all
parameters provide safety for samples and
cultures in medicine, life science, environmental
technology, bacteriology, virology, biology,
biotechnology and zoology.
 a wide range of options for programming and
documentation using interfaces, Celsius software,
integrated log memory and chip cards (features
dependent on the controller class)