Professional Documents
Culture Documents
Flange leakag: PEQ: allowable stress #60382 - 09/10/14 06:56 AM 0 registered (), 83
Guests and
1 Spider
waterguy
online.
I have a pipe stress spec that states "while using equivalent Key:
Admin,
Global Mod,
Member
pressure method if leakage is detected the same may be Mod
rechecked with 1.5 x allowable for operating case".
Registered:
01/24/11
March
Posts: 57
My question is where and how do you change the allowable for Su M Tu W Th F Sa
Loc: Illinois, the recheck?
USA 1 2 3 4 5 6 7
Top 8 9 10 11 12 13 14
15 16 17 18 19 20 21
Re: Flange leakag: PEQ: allowable stress
[Re: #60392 - 09/10/14 10:09 AM
22 23 24 25 26 27 28
waterguy]
29 30 31
Dave Diehl
The flange rating data is stored in two files found in the SYSTEM Forum Stats
folder - e.g., ASME-2009.FLG and ASME-2009.G.
Change one line in the FLG file to use 1.5 times the rating. In the 11739 Members
Member
Loc: Houston, I suggest you save this in a separate set - e.g., ASME-
Max Online: 303 @
TX, USA 2009_times_1.5.FLG and ASME-2009_times_1.5.G.
01/28/20 11:58 PM
Verify proper use...
Re: Flange leakag: PEQ: allowable stress
[Re: #60394 - 09/10/14 10:57 AM
waterguy]
waterguy
Thanks Dave,
Member
I hate sound stupid, but where do I find the SYSTEM folder?
Registered:
01/24/11
Posts: 57
Loc: Illinois,
USA
Top
Re: Flange leakag: PEQ: allowable stress
[Re: #60395 - 09/10/14 10:59 AM
waterguy]
Dave Diehl
easiest?
On CAESAR II main menu, select Utilities. There you will see
Member
"open System folder".