Fanuc 21i-ta gridshift issues

Fanuc 21i-a t controller


Absolute digital encoders
Cincom BL12 type V machine
2 dual axis controllers (z1/x1 and y1/x2)
2 single servo ampli ers for spindles

The software for the machine was reloaded a few years ago.
Supposedly, everything was working correctly except for the Z zero postion.
This issue has been programmed around for a few years.

The guy over this machine has stated they had the machine physically apart down to the z axis mechanics.
I wonder if they dropped the ballscrew nut??? down one side when they removed the top plate and pulled it up the other
side during reassembly without realizing that it would put the encoder o one revolution. Then never did a 1815 APZ
procedure.

The citizen guy claims that the 1850 gridshift value is always metric and is viewed as 0.000 mm. My investigations seem to
support this when making small adjustments to the 1850 z1 value. When a large adjustment is made unexpected changes
happen.

The factory 1850 value was set at -4076 in may of 2001. The 1850 value was set at 1000 on 12-13-2013. Currently the -4076
value nor the 1000 value are correct according to alignment procedures.

I investigated the possibility of the value being detect units. My thinking was that the multiplier may be close enough at
small increments to make detect units and 0.000mm units yield close results. When doing the math on the detect units it
still falls victim to the unexpected hard measurement values.

I have resorted to making small increment changes in the 1850 paramter to nd a good place to for usability. I have pinned
it down to a value of -650 or -649.

This is a xed headstock cincom with a stopper for barstock feed control. In the Z1 axis - takes you closer to the main
spindle while positive takes you further away. (backwards from most cincom machines).

At an 1850 value of -649 we are .085" from the procedural value of hard measurement.
At an 1850 value of -650 we are more than -.1181" from the procedural hard measurement.

Why is there such a large value shift when cincom claims that the value is only .001mm di erent?
Why would the abnormality happen at such a speci c number and be repeatable?
I am afraid to do the 1815 APZ procedure because currently we have a usable if somewhat downgraded machine. At the
same time though maybe that's all thats wrong with it?
My thought is that maybe and absolute reference mark is at the -649/-650 postion mark on the encoder and that throws it
o some how.

I have tried homing the machine within one revolution of the manual zero return mark and it doesn't seem to make any
di erence. I have been through the entire parameter manual and can't link any bad values to the issue. Maybe it is
something simple I have no knowledge of that someone with more expierience can answer easily. I believe I have done my
due diligence with researching parameter manuals, looking at other 1850 threads on this site and any others google will
pull up. I apologize if a similar issue has already been answered and I could gure it out from those answers.

Reply With Quote

03-03-2015,  10:40 PM #2

Join Date: Dec 2014


Other Brother
Country: UNITED STATES
Hot Rolled State/Province: Michigan
Posts: 710
Post Thanks / Like
Likes (Given): 337
Likes (Received): 438

I am not familiar with this machine but I am curious why you are changing the grid shift parameters on a machine with
absolute encoders. I sounds like you are on the edge of the grid and jumping to the next one. I would physically position
the slide at the home position, zero the grid shift in parameter 1850 and reset your 1815.4 APZ for that axis.
Maybe angelw/Bill, vancbiker, yardbird or some of the other smarter ones can help explain this. I have noticed this quite
often on several machines lately where there are numbers in the grid shift and the axis also use absolute encoders or
scales. I'd be interested in learning why they do this. I gured that it was an oversight as some builders use generic copies
of parameters and logic when setting up similar machines.

Reply With Quote

03-04-2015,  01:53 AM #3

Join Date: Jan 2014


Vancbiker
Country: UNITED STATES
Diamond State/Province: Washington
Posts: 4,544
Post Thanks / Like
Likes (Given): 826
Likes (Received): 2456

Sounds like you are "splitting" the grid with the 649, 650 shift. Usually you need to change the relationship of the screw and
the motor by approximately 1/2 turn then retry setting the shift.

Just for my own curiosity, is the ballscrew pitch 5mm?

Reply With Quote

03-04-2015,  02:13 AM #4

Join Date: Jun 2004


machtool
Location: Melbourne
Diamond Australia
Posts: 5,456
Post Thanks / Like

Originally Posted by Vancbiker


Sounds like you are "splitting" the grid with the 649, 650 shift. Usually you need to change the relationship of
the screw and the motor by approximately 1/2 turn then retry setting the shift.

Doesn't that only apply to dog and limit switch arrangements?

I appreciate what your saying for that style, get an axis were the switch point is horribly close to the encoder reference
marker, and it will jump a turn, if the switch is just marginally slow to make / break. Its the one and only time I've seen the
word "Hysteresis" used. (And it wasn't by me).

That shouldn't apply here were he has absolute encoders. Where you can make any encoder pulse the zero count.

Originally Posted by JLaugh


The citizen guy claims that the 1850 gridshift value is always metric and is viewed as 0.000 mm. My
investigations seem to support this when making small adjustments to the 1850 z1 value. When a large
adjustment is made unexpected changes happen.

I'd concur with that, the units are always in 1 micron, but I've never seen an axis jump like yours 0.2041", depending if your
-648 or - 649. (.085" / -.1181"). That's really weird and wonderful. I spent a few minutes with a calculator, I can't see any
rhyme or rhythm to the problem you are having.

It cant be a setting issue. I don't have a manual in front of me, but you can set that to either +/- 4095 or +/-999999

I wouldn't hesitate to do the Absolute Zero reset 1815.4 APZ. I've never understood why some guys leave the 1850 grid
shift parameters as set. The axis is lost anyway. I zero them out, then do the APZ, ne tune it if need be with grid shift and
drive on.

I read you are hesitant to do the Abs Zero Reset (1815.4). Its not that hard. I'd do it just because your grid shift seems to be
so screwed up.

Originally Posted by Other Brother


I have noticed this quite often on several machines lately where there are numbers in the grid shift and the
axis also use absolute encoders or scales. I'd be interested in learning why they do this.

I'd note this guy had a setting of -4076 as of May 2001. That surely must have been a Factory setting.

I have a theory, having visited several Japanese manufacturers. Systems / Fanuc are commissioned by the electrical /
electronic guys. They get the system to function. And set a rough Zero, that ties in with the software over travel
parameters.So the machine is safe.

Between the machine coming to life, and going out the door, the mechanical / Q.C guys have to make two spindle's look at
each other, or a turret get to true centre line. Those guys use the Grid-shift, as its all ready in the ballpark. And less power
downs at the Case level, as you would get with 1815. 1850 is virtually instant.

Down here, in the eld, on a one-o machine, I cancel Grid-Shift and just get the zero position correct.

Regards Phil.

Reply With Quote

03-04-2015,  03:26 AM #5

Join Date: Jan 2014


Vancbiker
Country: UNITED STATES
Diamond State/Province: Washington
Posts: 4,544
Post Thanks / Like
Likes (Given): 826
Likes (Received): 2456

Originally Posted by machtool


Doesn't that only apply to dog and limit switch arrangements?

I'm pretty sure this can happen with absolute systems. This gets tied in with the reference counter parameter somehow.
Here is a quote from a Fanuc manual I have about the reading of the absolute encoders at power up after setting a new
grid shift.

"APC communication is performed to establish the current position. The distance from the origin is calculated at that time.
The distance from the grid is also calculated. This value is assigned to a reference counter. This enables the grid to be
established. The sequence of step 1a is therefore not required".

Step 1a describes a dog type reference return system.

Originally Posted by machtool


I appreciate what your saying for that style, get an axis were the switch point is horribly close to the encoder
reference marker, and it will jump a turn, if the switch is just marginally slow to make / break. Its the one and
only time I've seen the word "Hysteresis" used. (And it wasn't by me).

The reason that sometimes you "split" a grid with dog and switch/sensor reference can be hysteresis in the switch or
sensor. The other reason is within the Fanuc system itself. Again another quote from my document.

"After a signal indicating indicating that the deceleration dog has been turned o is output to the hardware, it takes some
time (up to 20ms) for the software in the digital servo to recognize the signal. In addition, the time required for the
recognition varies. As a result , if the deceleration dog is too close to the origin, the software sometimes fails to capture the
signal".

Reply With Quote

03-04-2015,  04:36 AM #6
Join Date: Jun 2004
machtool
Location: Melbourne
Diamond Australia
Posts: 5,456
Post Thanks / Like

Originally Posted by Vancbiker


I'm pretty sure this can happen with absolute systems. This gets tied in with the reference counter parameter
somehow. Here is a quote from a Fanuc manual I have about the reading of the absolute encoders at power
up after setting a new grid shift.

"APC communication is performed to establish the current position. The distance from the origin is calculated
at that time. The distance from the grid is also calculated. This value is assigned to a reference counter. This
enables the grid to be established. The sequence of step 1a is therefore not required".

I dont agree with the part about having to move the motor / encoder half a turn.

"APC communication is performed to establish the current position

I'm pretty sure that just means in my best Japanese / English conversion, The control just knows the current position, due
to back up battery of the encoders. Despite the position where you hit the E.Stop. I.E it catches the position of encoder,
even with the power o . Most tyipically with Z axis that drop. Absolute encoders still know where it's at.

Reply With Quote

03-04-2015,  04:42 AM #7
Join Date: Jun 2004
machtool
Location: Melbourne
Diamond Australia
Posts: 5,456
Post Thanks / Like

Originally Posted by Vancbiker


The reason that sometimes you "split" a grid with dog and switch/sensor reference can be hysteresis in the
switch or sensor. The other reason is within the Fanuc system itself. Again another quote from my document.

"After a signal indicating indicating that the deceleration dog has been turned o is output to the hardware, it
takes some time (up to 20ms) for the software in the digital servo to recognize the signal. In addition, the time
required for the recognition varies. As a result , if the deceleration dog is too close to the origin, the software
sometimes fails to capture the signal".

It speci cally mentions a "deceleration dog". Surely theres no dog's or switches, on an absolute axis?

Originally Posted by Vancbiker


Step 1a describes a dog type reference return system.

Bro's we need to get on the same page. Woof, Woof. No dogs on an absolute axis.
Reply With Quote

03-04-2015,  05:08 AM #8
Join Date: Dec 2007
Tonytn36
Location: Southeastern US
Diamond Posts: 6,401
Post Thanks / Like
Likes (Given): 845
Likes (Received): 2806

It is possible he is at the roll-over point of the encoder. Even on a 32,000 count absolute encoder there is a roll-over to
zero. There may also be a rotation count pulse. My suggestion is to look at the encoder count in the parameters (if
available on fanuc, I can't remember). However, I would also do the APZ reset. This will re-sync the encoder count to
machine zero. I also never use grid shift on Fanuc 21i's as there is no need with the APZ procedure.

Reply With Quote

03-04-2015,  05:40 AM #9
Join Date: Jun 2004
machtool
Location: Melbourne
Diamond Australia
Posts: 5,456
Post Thanks / Like

Originally Posted by Tonytn36


It is possible he is at the roll-over point of the encoder. Even on a 32,000 count absolute encoder there is a
roll-over to zero.

Wouldn't the case be, on a 32,000 count encoder, thats over the entire travel of the axis, I:e multiple turns? Fill me in, who's
making a 32,000 pulse per rev encoder?

With due respect, he's having problems at - 649 or - 650, on a Fanuc 21i

I'll stroke your cock with this 32,000 pulse thing. That's really disingenous. This bloke would be lucky to have 4k to play
with.

Reply With Quote

03-04-2015,  12:54 PM #10


Join Date: Jan 2014
Vancbiker
Country: UNITED STATES
Diamond State/Province: Washington
Posts: 4,544
Post Thanks / Like
Likes (Given): 826
Likes (Received): 2456

Originally Posted by machtool


It speci cally mentions a "deceleration dog". Surely theres no dog's or switches, on an absolute axis?

Bro's we need to get on the same page. Woof, Woof. No dogs on an absolute axis.

I should have split up my reply better to not add confusion.

When I mentioned the dog type reference, it was an attempt to explain one cause of "splitting" a grid.

The Fanuc manual I am referencing this info from is outlining di erences between behaviors of absolute and incremental
encoders. That is why the end of the quote says "The sequence of step 1a is therefore not required". Earlier in the book,
step 1a described dog type reference. It's just a roundabout way the manual tells us that abs encoders do not need a dog
type reference but still establish a "logical" grid based on a calculation.

Reply With Quote

03-04-2015,  08:15 PM #11


Join Date: Dec 2007
Tonytn36
Location: Southeastern US
Diamond Posts: 6,401
Post Thanks / Like
Likes (Given): 845
Likes (Received): 2806

Originally Posted by machtool


Wouldn't the case be, on a 32,000 count encoder, thats over the entire travel of the axis, I:e multiple turns? Fill
me in, who's making a 32,000 pulse per rev encoder?

With due respect, he's having problems at - 649 or - 650, on a Fanuc 21i

I'll stroke your cock with this 32,000 pulse thing. That's really disingenous. This bloke would be lucky to have
4k to play with.

We have lots of absolute encoders in our facility with 18-bit (262,144 steps) single rev with 32,768 revs available before roll-
over. These are TR encoders. Obviously not Fanuc. Was just mentioning a possibility.
Reply With Quote

03-04-2015,  10:06 PM #12

Join Date: Jan 2015


JLaugh
Country: UNITED STATES
Plastic State/Province: Tennessee
Posts: 36
Post Thanks / Like
Likes (Given): 20
Likes (Received): 19

While I have not dissassembaled the machine myself, from what I know of the system involved and, from what the
maintenance manual says I don't believe there are any dogs or limit switches.

The reason I am afraid to do an 1815.4 procedure is the massive jump at -649/-650 makes me think there could be an issue
with the encoder itself. The machine is currently operating and has orders pending for atleast the next 3 weeks. If I do an
1815.4 and we nd out that the encoder is faulty and must be replaced it could cause issues with getting our orders out.

Our sta including myself is very young compared to what I would think the industry average is. We are very methodical in
our approach. I hope this is conveyed in my original post. Being prudent and cautious is how we avoid missteps and make
sure we have the time to resolve issues before they e ect our customers.

At the -649/-650 setting the "jump" is even more than .2041. The z1 axis setting procedure says to put the z1 axis at
machine postion z1=0.0. The face of the main spindle (just to be clear I know this means the spindle bore's face and not the
collet) to the top plate measurement should be 43.5mm (1.7126"). At -650 we have to back out to machine position .085"
for the gauge blocks to t. At -649 we move to -.1181 machine postion and are still around .100" from touching the gauge
blocks.

Currently we are turning 304SS tubing into precision spacers at 13s per part so we want to nish that before we have any
down time.

How would I gure out how many detect units or pulses are in a turn of the encoder?
Can an encoder just "go bad"?
This encoder is probably about 15 years old.
If the enocder is bad would the machine even work at all?
What kind of fault in the encoder could cause the jump?

If there was some kind of fault in the encoder that could show up during an 1815.4 procedure?

Could it be as simple as someone took the top plate o the ball screw "nut" letting the "nut" down the left side of the screw
and then pulling it up the right side during reassembly, putting the encoder o one revolution? I'm leaning torwards doing
the 1815.4 but, want to be sure before I do so.

Reply With Quote

03-05-2015,  04:29 PM #13

Join Date: Aug 2002


Ox Location: West Unity, Ohio
Diamond Posts: 25,252
Post Thanks / Like
Likes (Given): 5531
Likes (Received): 7957

Is this a belt driven axis?

If so - just jump the belt X amount of teeth.

If direct drive, it likely has no keyway, and you would want to scribe a line in the shaft and connector, and slip it to your
expected location as closely as possible. Then you would be closer to ZERO and further from the possible "bad" spot in the
encoder. (Kan't really be bad if it's making good parts w/o comping most other Z moves, so ....)

I wouldn't be scared of the ZRN procedure, but I have experience with it too, and I can appreciate your reasoning here.
The mechanical procedure of the belt of yoke trick may not cause as much hesitance. (in the older folks especially!)

--------------------

Think Snow Eh!


Ox

Reply With Quote

03-05-2015,  07:38 PM #14

Join Date: Jan 2015


JLaugh Country: UNITED STATES
Plastic State/Province: Tennessee
Posts: 36
Post Thanks / Like
Likes (Given): 20
Likes (Received): 19

It is a direct drive axis.

Everytime we edit the 1850 we have to powerdown and then do what cincom calls a manual zero return (alarm page calls it
a "Z axis ZRN")

It's on a special page in the maintenance section. It just dawned on me, surely this isn't a built in shortcut to doing a
1815.4? If so that rules out that xing the problem.

Reply With Quote


03-05-2015,  07:52 PM #15
Join Date: Aug 2002
Ox
Location: West Unity, Ohio
Diamond Posts: 25,252
Post Thanks / Like
Likes (Given): 5531
Likes (Received): 7957

I've never used BOTH 1850 and 1815 on the same machine before.

--------------------

Think Snow Eh!


Ox

Reply With Quote

Other Brother liked this post

03-05-2015,  08:48 PM #16


Join Date: Dec 2014
Other Brother
Country: UNITED STATES
Hot Rolled State/Province: Michigan
Posts: 710
Post Thanks / Like
Likes (Given): 337
Likes (Received): 438

Originally Posted by JLaugh


It is a direct drive axis.

Everytime we edit the 1850 we have to powerdown and then do what cincom calls a manual zero return
(alarm page calls it a "Z axis ZRN")

It's on a special page in the maintenance section. It just dawned on me, surely this isn't a built in shortcut to
doing a 1815.4? If so that rules out that xing the problem.

So how do you reference the slide after editing 1850 and powering down? Does 1815.4 turn to a zero? Anytime you change
a grid shift on Fanucs you have to power down.

Reply With Quote

Quick Navigation CNC Machining Top

« Previous Thread | Next Thread »

Bookmarks Posting Permissions

Digg You may not post new threads BB code is On


del.icio.us You may not post replies Smilies are On
You may not post attachments [IMG] code is On
StumbleUpon
You may not edit your posts [VIDEO] code is On
Google   HTML code is O

Forum Rules

ABOUT PRACTICAL MACHINIST WEBSITE LINKS STAY CONNECTED

With more than 10.6 million unique visitors over the last Registration
year, Practical Machinist is the most visited site for Forum Search
Forum Rules
metalworking professionals. Practical Machinist is the Advertise Become a forum member. Register today.
easiest way to learn new techniques, get answers quickly Contact Us
and discuss common challenges with your peers. Register
Powered by vBulletin® Version 4.2.2 Sign up for our e-newsletter.
for the world’s largest manufacturing technology forum
for free today to stay in the know. Copyright © 2019 vBulletin Solutions, Inc. All rights
reserved.
Learn more about us.

© 2019 Copyright Practicalmachinist.com. All Rights reserved. Forum Advertise A liate Program Disclosure Privacy Policy Cookie Policy Contact Us Sitemap Top

You might also like