You are on page 1of 2

SAUDI ARAMCO ID/PID - 24-Mar-2016 - REV. 2015.09.01 (Standards Cutoff - September 6, 2015) Rev. 2015.09.

01 6-Sep-15
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Laboratory Testing Inspection SAIC-A-1009 24-Mar-16 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

The Geotechnical Contractor shall utilize Inspection Department's list of


SAES-A-113
A1 Saudi Aramco approved Third Party laboratories with specific approval in
Sec. 5.2.1.2
geotechnical category, for Laboratory testing.

Classification testing shall be in accordance with ASTM D2487. Other soil


SAES-A-113
A2 properties shall be determined in accordance with ASTM D1557, D1883,
Sec. 6.5.1/6.5.2
D2166, D2435, D2850, D4253, D4254, and D4318

Laboratory CBR tests should use the "three-point" method along with soil
SAES-A-113
A3 density results to estimate the in-situ CBR and the CBR at recommended
Sec. 6.5.2
compaction density

Representative chemical analyses of soil and groundwater samples shall


be performed in accrdance with SAES-Q-009, AASHTO T290 and T291. SAES-A-113
A4
Water Soluble and chloride Tests are required where concrete will be in Sec. 6.5.3
contact with soil.

All soil and rock samples shall be retained for a minimum of two months
SAES-A-113
A5 after completion of the geotechnical investigation. Samples must be kept
Sec. 5.5
according to ASTM D4220 and D5079.

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-A-113 -- Geotechnical Engineering Requirements, 19 June 2012

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

Saudi Aramco: Company General Use


*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Saudi Aramco: Company General Use