Machine setting parameters
1. Print
2. Main Menu, Setting and
Care, Machine Tools, Preferences – Change to R&D level
Settings
The Z high Position during purge from H.P (TOP)
The X table position during manual loading (close to the LEC side)
Z lower position ink profile touching the printing table (From this value the application
will calculate the print high)
Minimum gap for the Print Head above the printing table during print
Iron roller lower position touching the printing table (From this value the application
will calculate the iron roller high)
OLD - Loader bar lower position Suction cup touching the printing table
NEW - Loader bar lower position Suction cup touching the NIP (including blankets)
The lowest unloader position suction cup touching the printing table
Not relevant – Not supporting automatic unloading from the front manual pins
Z motor delta offset effect only on the front side (Bigger number will move motor down)
Loader bar delta offset left (Bigger number will move the left LB motor down)
Loader bar delta offset right (Bigger number will move the right LB motor down)
Unloader bar offset left (Bigger number will move the left UB motor down)
Unloader bar offset right (Bigger number will move the right UB motor down)
Iron Roller offset left (Bigger number will move the front IR motor down)
Iron Roller offset (Bigger number will move the rear IR motor down)
Y position for start printing Manuel loading front side (Start image on media)
Y position for start printing Manuel loading rear side (Start image on media)
Tetris alignment parameter (Will be enter automatic after Tetris tent calibration)
Tetris alignment parameter (Will be enter automatic after Tetris tent calibration)
The distance from the X POT to maintenance bath pickup position during first initialize
and the maintenance bath is on the printing table
Table type
Ink colors
Special data file to get extra accuracy, need to leave unmarked (R&D use only)
Application define the UV safe zone. The safe zone determines when the UV
external shutter is allowed to open and when it must remain closed
Activating the Air Jets Enable = 1 Disable = 0
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.