You are on page 1of 3

p

JASA KONSULTASI PERENCANAAN PEKERJAAN


INSTRUMENTASI TANKI STORAGE CPO DI PERAK

PEL-TP-00-INS-DS-009 DATASHEET FOR FLOW TRANSMITTER Page 3 of 5


CLIENT APPROVAL
REV DATE DESCRIPTION PREPARED CHECKED APPROVED
BY DATE
0 8-Aug-16 IFB YF DW BA
1 6-Feb-17 IFB ND DW BA

TABLE OF CONTENT

No. Document No. Page Tittle Remarks


1 PEL-TP-00-INS-DS-009 1 COVER
2 PEL-TP-00-INS-DS-009 2 REVISION HISTORICAL SHEET
3 PEL-TP-00-INS-DS-009 3 TABLE OF CONTENT
4 PEL-TP-00-INS-DS-009 4 DATASHEET FLOW TRANSMITTER (CORIOLIS)
5 PEL-TP-00-INS-DS-009 5 LIST FLOW TRANSMITTER (CORIOLIS)
p

JASA KONSULTASI PERENCANAAN PEKERJAAN


INSTRUMENTASI TANKI STORAGE CPO DI PERAK

PEL-TP-00-INS-DS-009 DATASHEET FOR FLOW TRANSMITTER Page 4 of 5

CLIENT APPROVAL
REV DATE DESCRIPTION PREPARED CHECKED APPROVED
BY DATE
0 8-Aug-16 IFB YF DW BA
1 6-Feb-17 IFB ND DW BA

1 Tag Number See List


GENERAL

2 Services See List


3 P&ID Number See List
4 Line / Equipment Number See List
5 Area Classification / Enclosure Rating Not Classified / IP 65 as minimum
6 Fluid State Liquid
7 Operating Pressure Design Pressure See List See List
CONDITION
PROCESS

8 Operating Temperature Design Temperature See List See List


9 Operating Flow See List
10 Mass Density 887 kg/m3
11 Viscosity 44 cP
12 Vibration No
13 Type Coriolis (note 4)
14 Wetted Parts Material 316 SS (note 4)
15 Liquid 0.1 % (note 4)
Mass Flow Accuracy
16 Gas 0.5 % (note 4)
SENSOR

17 Density Accuracy Liquid 0.0005 g/cm3 (Note 4)


18 Mounting Remote Type Ingress Protection Yes IP 66
19 Mounting Integral Type Ingress Protection Yes IP 66
20 Self-Draining Yes
21 Capability Two-Phase Flow note 4
22 Factoty-fitted Insulation & Heat Tracing note 4
23 Process Connection NPTF (note 4)
24 Type Electronic
25 Function Transmitter
26 Body and Bolting Material 316 SS (note 4)
27 Liquid 0.15 % (note 4)
Mass Flow Accuracy
28 Gas 0.5 % (note)
TRANSMITTER

29 Density Accuracy Liquid 0.0005 g/cm3 (Note 4)


30 Power Supply 24 VDC (Power Loop)
31 Transmitter Output 4-20 mA, Smart HART Type
32 Meter Type Integrated with LCD
33 Cable Entry / Electrical Connection 1/2" NPTF
34 Cabling (Note 4)
35 Housing Material 316 SS (Note 4)
36 Hazardous Approval Not Classified
37 Ingress Protection Min. IP65 as minimum
38 Lightning/Surge Protection Yes, Include (Note 4)
39 Microprocessor Based Smart Type Yes
OPTIONS

40 Flow Calculation With Fully Programmable Yes


41 Calibration Certifcate Yes, Include
42 SIL Compliance note 4
43 Accessories MFR STD
44 Manufacturer note 2
PURCHASE

45 Model No note 4
46 Quantity 1 ea
47
48
NOTE :
* TBA = To Be Advice
1 Vendor shall provide A 316 SS name plate and have permanently attached. The name plate show the tag number, range, serial number
and year of manufacturer as a minimum.
2 Manufacturer shall be presented in vendor list Client approval.
3 The selected ranges of transmitter to be confirmed / advised by pressure manufacturer in accordance with their available standard range.
4 Vendor To Advise.
5 The transmitter shall be a direct measurement of the mass flowrate and the density with local Indicator displaying
some information as below
- Flowrate - Mass Flow Totalizing
- Density - Volume Flow Totalizing
- Flowing Temperature
p

JASA KONSULTASI PERENCANAAN PEKERJAAN INSTRUMENTASI TANKI STORAGE CPO DI PERAK

PEL-TP-00-INS-DS-009 DATASHEET FOR FLOW TRANSMITTER Page 5 of 5

CLIENT APPROVAL
REV DATE DESCRIPTION PREPARED CHECKED APPROVED
BY DATE
0 8-Aug-16 IFB YF DW BA
1 6-Feb-17 IFB ND DW BA

LIST OF FLOW TRANSMITTER (CORIOLIS)

PID No. Line / Equipment Pressure Temperature


No Tag No. Services Operating Flow
PEL-TP-00-PRO- No. Operating Design Operating Design
1 FT-001 From Pig Receiver to Tank DWG-001 SHEET 4 OF 11 6"-PL-011-A01A 315000 kg/hr 9.25 barg 13 barg 30 deg C 70 deg C
2 FT-002 From Pig Receiver to Tank DWG-001 SHEET 4 OF 11 6"-PL-012-A01A 315000 kg/hr 9.25 barg 13 barg 30 deg C 70 deg C
3 FT-003 From Pig Receiver to Tank DWG-001 SHEET 4 OF 11 6"-PL-013-A01A 315000 kg/hr 9.25 barg 13 barg 30 deg C 70 deg C
4 FT-004 From Pig Receiver to Tank DWG-001 SHEET 5 OF 11 6"-PL-014-A01A 315000 kg/hr 9.25 barg 13 barg 30 deg C 70 deg C
5 FT-005 From Pig Receiver to Tank DWG-001 SHEET 5 OF 11 6"-PL-015-A01A 315000 kg/hr 9.25 barg 13 barg 30 deg C 70 deg C
6 FT-006 From Pig Receiver to Tank DWG-001 SHEET 5 OF 11 6"-PL-045-A01A 315000 kg/hr 9.25 barg 13 barg 30 deg C 70 deg C
7 FT-007 From Pump Outlet to Filling Station DWG-001 SHEET 6 OF 11 6"-PL-025-A01A 108000 kg/hr 2.39 barg 13 barg 30 deg C 70 deg C
8 FT-008 From Pump Outlet to Filling Station DWG-001 SHEET 6 OF 11 6"-PL-029-A01A 108000 kg/hr 2.39 barg 13 barg 30 deg C 70 deg C
9 FT-009 From Pump Outlet to Filling Station DWG-001 SHEET 7 OF 11 6"-PL-033-A01A 108000 kg/hr 2.39 barg 13 barg 30 deg C 70 deg C
10 FT-010 From Pump Outlet to Filling Station DWG-001 SHEET 7 OF 11 6"-PL-037-A01A 108000 kg/hr 2.39 barg 13 barg 30 deg C 70 deg C