Verify that following instruments are in place properly and are in good working
condition.
S. No KKS DESCRIPTION
1 10PGB30CL501 Expansion Tank Level Gauge Glass
2 10PGB11CP101 CCW Pump-A Suction Filter Differential Pressure
Transmitter
3 10PGB11CP501 CCW Pump-A Suction Pressure Gauge
4 10PGB11CP502 CCW Pump-A Discharge Pressure Gauge
5 10PGB12CP101 CCW Pump-B suction Filter Differential Pressure
Transmitter
6 10PGB12CP501 CCW Pump-B Suction Pressure Gauge
7 10PGB12CP502 CCW Pump-B Discharge Pressure Gauge
8 10PGB13CP001 CCW Pumps Discharge Header Pressure Switch
9 10PGB13CP101 CCW Pumps Discharge Header Pressure Transmitter
10PGB13CT301 CCW Heat Exchangers CCW Inlet Temperature
Thermocouple
10PGB13CP501 CCW Heat Exchanger-A CCW Inlet Pressure Gauge
10PGB13CP502 CCW Heat Exchanger-B CCW Inlet Pressure Gauge
10PGB21CT501 CCW Heat Exchanger-A CCW Outlet Temperature
Gauge
10PGB21CT502 CCW Heat Exchanger-B CCW Outlet Temperature
Gauge
10 10PGB20CP101 CCW Heat Exchangers Outlet Header Pressure
Transmitter
10PGB20CT301 CCW Heat Exchangers Outlet Header Temperature
Thermocouple
11 10PGB23CP501 HRSG-1 CCW Supply Pressure Gauge
10PGB23CT502 HRSG-1 CCW Return Temperature Gauge
12 10PGB23CP502 HRSG-2 CCW Supply Pressure Gauge
10PGB23CT504 HRSG-2 CCW Return Temperature Gauge
13 10PGB24CP504 ST Generator Cooler CCW Supply Line Pressure
Gauge
10PGB14CT504 ST Generator Coolers CCW Return Temperature
Gauge
10PGB24CT502 Vacuum Pump-A CCW Supply Temperature Gauge
10PGB14CT502 Vacuum Pump-A CCW Return Temperature Gauge
10PGB24CT503 Vacuum Pump-B CCW Supply Temperature Gauge
10PGB14CT503 Vacuum Pump-B CCW Return Temperature Gauge
10PGB22CP501 Gas Turbines CCW Supply Header Pressure Gauge
10PGB22CT501 Gas Turbines CCW Supply Header Temperature
Gauge
10PGB22CT502 GT-1 Generator Coolers CCW Return Header
Temperature Gauge
10PGB22CT506 GT-2 Generator Coolers CCW Return Header
Temperature Gauge
10PGB14CP501 Sampling Room CCW Supply Header Pressure
Gauge
10PGB14CT501 Sampling Room CCW Return Header Temperature
Gauge
S. No Description Status
1 Closed Cycle Cooling Water Pump-A Breaker RACKEDIN/REMOTE
2 Closed Cycle Cooling Water Pump-B Breaker RACKEDIN/REMOTE
3 CCW Pump-A Discharge MOV ON
4 CCW Pump-B Discharge MOV ON
5 ST Lube Oil Cooler-A CCW Inlet MOV ON
6 ST Lube Oil Cooler-B CCW Inlet MOV ON