ILF Consulting Engineer

Al Majan House, SHEET NO.: 3 OF 6


pH Analyzer
1st. floor, Al Khuwair SPEC NO. : A4-C925-ID-02-014
OMAN JOB NO. : 925
CLIENT : SEPTECH MUSCAT LLC SL.NO BY CHKD APPRD DATE REV
CONSULTANT : ILF Consulting Engineer - OMAN 1 RS KRR CS 26.11.09 0
PROJECT: 5 MIGD MOBILE SEA WATER 2 SS KRR CS 22.12.09 A
DESALINATION PLANT
1 Tag No 925-AIT-40 925-AIT-41 925-AIT-42
2 Service Filtered Water Filtered Water Filtered Water

3 Line No. 300-PVCU-FW-20 300-PVCU-FW-25 300-PVCU-FW-30


GENERAL

4 Line Size DN300 DN300 DN300


5 Process Fluid State Liquid Liquid Liquid
6 Specific Gravity Kg/m3 1.03 1.03 1.03
7 Viscosity CP 1 1 1
8 Pressure bar.G (Operating) 5.5 A 5.5 A 5.5 A
9 Temperature OC (Operating) 35 35 35
10 Type In-Line In-Line In-Line
11 Mounting Type Submersible Submersible Submersible
12 Process Connection/ Size 3/4" NPT 3/4" NPT 3/4" NPT
13 Insertion Length 1.5" 1.5" 1.5"
14 Electrode Coat Resistant Glass Coat Resistant Glass Coat Resistant Glass
15 Operating Range pH 0-12 pH 0-12 pH 0-12 pH
SENSOR

16 Instrument Range pH 0-14 pH 0-14 pH 0-14 pH


17 Enclosure class IP-65 IP-65 IP-65
18 Response Time 3 Seconds for 90% 3 Seconds for 90% 3 Seconds for 90%
19 Accuracy +/- 0.01 pH +/- 0.01 pH +/- 0.01 pH
20 Sensor cable PIN Leads PIN Leads PIN Leads
21 Length 6 Mts. 6 Mts. 6 Mts.
22 Power supply From the Transmitter From the Transmitter From the Transmitter
23 Temperature Comp. PT-100,Tinned Leads PT-100,Tinned Leads PT-100,Tinned Leads
24 Primary Electrode Glass Glass Glass
MATERIAL

25 Reference Electrode Antimony Antimony Antimony


26 Flow Through chamber NA NA NA
Anoidized Alluminium, Powder Anoidized Alluminium, Anoidized Alluminium, Powder coat
27 Transmitter Housing
coat Polyurethane Powder coat Polyurethane Polyurethane
28 Type Electronic Electronic Electronic
29 Accuracy +/- 1% Of Span +/- 1% Of Span +/- 1% Of Span
30 Display Dual Line LCD display Dual Line LCD display Dual Line LCD display
Anoidized Alluminium, Powder Anoidized Alluminium, Anoidized Alluminium, Powder coat
31 Housing
coat Polyurethane Powder coat Polyurethane Polyurethane
32 Mounting Locally Mounted on 2" Pipe Locally Mounted on 2" Pipe Locally Mounted on 2" Pipe
TRANSMITTER

33 Power supply 24 VDC, 2 Wire 24 VDC, 2 Wire 24 VDC, 2 Wire

34 Transmitter output Isolated 4 - 20mA DC Isolated 4 - 20mA DC Isolated 4 - 20mA DC

35 Local indication Required, Digital Required, Digital Required, Digital


36 Enclosure class WP To IP-65 WP To IP-65 WP To IP-65
37 Area Classification Safe Safe Safe
38 Cable entries 1/2" NPT(F) 1/2" NPT(F) 1/2" NPT(F)
39 Mfr. * * *
40 Sensor model no. * * *
41 Transmitter Model no. * * *
Notes: *Vendor to specify

1 Automatic Calibration and Cleaning system required.


2 The Transmitter shall have tag number plates(SS plate) firmly attached at a visible place.