You are on page 1of 10

PERHITUNGAN ANALISA KOEFISIEN

Diameter
pompa 60 cm
as dam A Q =
=
3m 3m =
D Q' =

B =
D =
L =
=
=
Ɩ =
=
A =
=
i =
0,41 m =
=
35 m
Perhitungan Debit Menggunakan Huk
Q =
=
8,33 x 10-4 =
K =
=
RHITUNGAN ANALISA KOEFISIEN PERMEABILITAS DI PW 1

12 m3/h
3,3 x 10-3 m3/s
3,3 x 10-5 cm3/s
Q/4
8,33 x 10-4 m3/s
0.6 m
πD
3,14 * 0,6
1.884 m
1/4 πD
0.471 m
0,6 x 35 m
21 m
dh/dL
0,41/1,03
0.39805825 m

itungan Debit Menggunakan Hukum Darcy :


K.I.A Keterangan :
K x (dh/dL) x A K = hydraulic conductivity (m/hari)
K x 0,398 x 0,6 x 35 I = hydraulic gradient (dh/dL)
9,9 x 10-5 m/s A = Luas penampang akuifer
-7
9,9 x 10 cm/s
PERHITUNGAN ANALISA KOEFISIEN
Diameter
pompa 60 cm
as dam A
Q =
=
3m 3m
=
D Q' =
B =
D =
L =
=
=
Ɩ =
=
A =
=
i =
1,465 m =
=
35 m
Perhitungan Debit Menggunakan Huk
Q =
=
1,04 x 10-3 =
K =
=
RHITUNGAN ANALISA KOEFISIEN PERMEABILITAS DI PW 2

15.03 m3/h
4,1 x 10-3 m3/s
4,1 x 10-5 cm3/s
Q/4
1,04 x 10-3 m3/s
0.6 m
πD
3,14 * 0,6
1.884 m
1/4 πD
0.471 m
0,6 x 35 m
21 m
dh/dL
1,465/1,305
1.12260536 m

itungan Debit Menggunakan Hukum Darcy :


K.I.A Keterangan :
K x (dh/dL) x A K = hydraulic conductivity (m/hari)
K x 1,122 x 0,6 x 35 I = hydraulic gradient (dh/dL)
4,03 x 10-5 m/s A = Luas penampang akuifer
-7
4,03 x 10 cm/s
PERHITUNGAN ANALISA KOEFISIEN
Diameter
pompa 60 cm
as dam A
Q =
=
3m 3m
=
D Q' =
B =
D =
L =
=
=
Ɩ =
=
A =
=
i =
1,38 m =
=
35 m
Perhitungan Debit Menggunakan Huk
Q =
=
1,07 x 10-3 =
K =
=
RHITUNGAN ANALISA KOEFISIEN PERMEABILITAS DI PW 3

15.45 m3/h
4,29 x 10-3 m3/s
4,29 x 10-5 cm3/s
Q/4
1,07 x 10-4 m3/s
0.6 m
πD
3,14 * 0,6
1.884 m
1/4 πD
0.471 m
0,6 x 35 m
21 m
dh/dL
1,38/1,04
1.32692308 m

itungan Debit Menggunakan Hukum Darcy :


K.I.A Keterangan :
K x (dh/dL) x A K = hydraulic conductivity (m/hari)
K x 1,122 x 0,6 x 35 I = hydraulic gradient (dh/dL)
3,84 x 10-5 m/s A = Luas penampang akuifer
-7
3,84 x 10 cm/s
PERHITUNGAN ANALISA KOEFISIEN
Diameter
pompa 60 cm
as dam A
Q =
=
3m 3m
=
D Q' =
B =
D =
L =
=
=
Ɩ =
=
A =
=
i =
1,12 m =
=
35 m
Perhitungan Debit Menggunakan Huk
Q =
=
1 x 10-3 =
K =
=
RHITUNGAN ANALISA KOEFISIEN PERMEABILITAS DI PW 4

16 m3/h
4 x 10-3 m3/s
4 x 10-5 cm3/s
Q/4
1 x 10-3 m3/s
0.6 m
πD
3,14 * 0,6
1.884 m
1/4 πD
0.471 m
0,6 x 35 m
21 m
dh/dL
1,12 / 1,8
0.62222222 m

itungan Debit Menggunakan Hukum Darcy :


K.I.A Keterangan :
K x (dh/dL) x A K = hydraulic conductivity (m/hari)
K x 0,62 x 6 x 35 I = hydraulic gradient (dh/dL)
7,9 x 10-5 m/s A = Luas penampang akuifer
-7
7,9 x 10 cm/s
TABEL NILAI PERMEABILITAS (K) HASIL PUMPING TEST
No Sumur Pompa Kedalaman (m) Diameter Pipa (m) Jarak ke As Dam (m) Debit (m3/h)
1 PW 1 35 0.6 3 12
2 PW 2 35 0.6 3 15.03
3 PW 3 35 0.6 3 15.45
4 PW 4 35 0.6 3 16
T
k (cm/s) Lugeon Range
9,9 x 10-7 <1
4,03 x 10-7 <1
-7
3,84 x 10 <1
-7
7,9 x 10 <1

You might also like