You are on page 1of 3

Field Observation Report

FOR No. HMMI - FOR - CQ - UT- 001

Work Item Reinforcing bar Originator Eko Ginting

Reviewed by E. J. Jeon
Contractor Takenaka
Approved by B. S. Kwak

Location Utility Rebar Fabrication Date 9-Mar-20

Specification/Rev SNI 03.2847-2013 Drawing/Rev 100.00-R-005

FIELD OBSERVATION REPORT

Requirement :
As per Standard Drawing No.100.00-R-005 and SNI 03.2847-2013, minimum rebar bending
1.
shall follow the table below :
Bar
D MIN
Size, db
(mm)
(mm)
10 60
13 80
16 100
19 115
22 135
25 150
29 235
32 260
2. Required date for completion is 16-Mar-20

RECOMMENDED DISPOSITION
Rework Repair ● Conditional release

The Present Condition The Completed Condition

Paint
Bar Size,
Shop
db (mm)
(mm)
Less than
10 55 minimum
13 70 diameter (Not
OK))
16 95 Not available at
19 120 rebar fabrication

22 135

25 150

Received by

Company Date Name


PROJECT NAME : HMMI (HYUNDAI MOTOR MANUFACTURING INDONESIA)
Building : Utility
Department : Construction Quality Date : 9-Mar-20
Pin 60mm is minimum diameter
Sel No. 1 Item Pin Ring Descrip Location Fabrication
for D10 rebar
Photo Inspection Finished

Pin 80mm for D13 shall be


Sel No. 2 Item Pin Ring Descrip Location Fabrication
provide
Photo Inspection Finished

Pin 100mm is minimum


Sel No. 3 Item Pin Ring Descrip Location Fabrication
diameter for D16 rebar
Photo Inspection Finished

HMMI 2 of 3
PROJECT NAME : HMMI (HYUNDAI MOTOR MANUFACTURING INDONESIA)
Building : Utility
Department : Construction Quality Date : 9-Mar-20
Pin 115mm for D19 rebar shall
Sel No. 4 Item Pin Ring Descrip Location Fabrication
be provide
Photo Inspection Finished

NOT AVAILABLE

Pin 135mm for D22 rebar shall


Sel No. 5 Item Pin Ring Descrip Location Fabrication
be provide
Photo Inspection Finished

NOT AVAILABLE

Pin 150mm for D25 rebar shall


Sel No. 6 Item Pin Ring Descrip Location Outside
be provide
Photo Inspection Finished

NOT AVAILABLE

HMMI 3 of 3

You might also like