You are on page 1of 5

Add Article

 FOR PERFORMANCE GUARANTEE

This article should include:-


 An amount equal to 5% of the tendered and accepted value of the work
(without limit) as performance guarantee.
 The time allowed for submission of the performance guarantee.
 Time for The Performance Guarantee shall be refunded to the
contractor soon after completion of the work on issuance of completion
certificate.

ARTICLE 8
 SHOULD BE INCLUDED

REPRESENTATIONS AND WARRANTIES OF THE PARTIES

1. The CLIENT hereby warrants that it is a business organization duly


incorporated and validly existing under the laws of Ethiopia and has the
corporate power to enter into and execute the present CONTRACT.

2. The CLIENT also warrants that the present CONTRACT shall be valid,
binding on and enforceable against it when executed by its authorized
executive official.

3. The SERVICE PROVIDER hereby warrants that it is a business organization


duly incorporated and validly existing under the laws of Ethiopia and has
the corporate power to enter into and execute the present CONTARCT.

4. The SERVICE PROVIDER also warrants that the present CONTRACT shall
be valid, binding on and enforceable against it when executed by its
authorized executive official.

5. The SERVICE PROVIDER further warrants that it has the requisite


professional skill and long-standing experience to carry out the elevator
Installation services contemplated by the present transaction.
ARTICLE 10
 SHOULD INCLUDE:-

1. The supplier should be liable and penalize for delays in performance

2. A Party shall exercise its right to cancel the CONTRACT by giving thirty
days advance written notice to the Party in default setting forth the
details of the material breach complained of.

3. All written notices required by virtue of the provisions of the present


CONTRACT shall be deemed as delivered when actually delivered by
hand or when sent by registered mail to the other Party and receipt of the
same is acknowledged in writing by the receiving Party.

ARTICLE 9
 SHOULD INCLUDED

1. The SERVICE PROVIDER shall warrant that the maintenance works it


Carries out by virtue of the present CONTRACT shall be free from any
defects in craftsmanship and shall be liable for any damage caused to
persons or property due to defects in workmanship.

2. The SERVICE PROVIDER shall correct or rectify, at its own expenses, any
defects in workmanship performed by its personnel.

 Add New Article

For The attached Detailed Technical Specification and FUJIZY Catalogue


Options as ELGI has provided in the Tender Documents

Elevator Basic Requirements and Technical Specification


N Basic Specification Required DK Provide
o. Specification FUJIZY
1 Capacity (kg) /Persons 800kg (10person) 800kg/10 Per
2 Speed (m/s) 1.6m/s 1.6m/s
3 Control type(microprocessor base) UP base ,VVVF VVVF
4 Traction Ratio 2:1 2:1
5 Machine Type PMSM (Inside Shaft ) SM
6 Factory Motor rating (Kw) Motor Rating 9.7kw
7 Car and Hoistway Door type Central Opening CO CO
8 Door net size W900 *H2100 900mmx2100m
m
9 Hoistway Dimensions (WxD in 2100mmx2000mm 2100mmx2000
mm) mm
10 Top floor height 4500mm 4500
11 Stop/ door (Name of floor served) 11(B,G,M,1,2..8) B,G,M,1,2…8
12 Machine Room MRL MRL
13 Power supply(v) 380v,AC 50Hz,3p 5L Provided
14 Lighting supply(v) 2220v Ac 1KVA/set Provided
15 Traction Media Diameter 10mmx5
10mmx4/8mmx5
16 Automatic Rescue ARD Device ARD provided
17 Door Sensor Type Full Height Infrared Full Curtain
light curtain Light
18 Factory Drawing and Specification Detailed Existing Spec. Attached
19 Hall/LOP position Indicator HPI /LOP All Floor All Served Floor
Display
20 Car Celling and Lighting Celling with LED Provided
21 Flooring Granite/PVC tiles PVC
22 Car width >/=1200 as Factory 1250mm
Draw.
23 Car depth >/= 1150 as Factory 1300mm
Draw.
24 Car height 2300mm 2300mm
25 Operation type Full collective Full collective
operation
26 Voice Annunciation Speech Arriving and Provided
next floor
27 Intercom Internal Com Provided
28 Hand Rail and Mirror Rear Car panel & half Provided
Mirror
29 Buffer Type Hydraulic type Provided
30 Fire system Emergence fire Provided

 Add New Article

For The detailed Elevator Installation and Commissioning Schedule

This Installation chart schedule should include:-

 Lists of detailed activities


 Specify time for each activities
 Specify time for commissioning and handover

You might also like