Purchase Specification for Blowers

Quantity N (x W + y S)

Duty Providing clean dry and oil free air for backwashing of filters

Equipment shall be designed to provide clean, dry. Oil free air at optimum
power consumption and least noise level. Twin Lobe type Rotary Air Blower,
operating below 1500 RPM is recommended. There should be provision in the
design to increase or decrease air out put from the blower to the extent of 20
%.

Type Twin Lobe Type Rotary air Blower.

Capacity As per design (Nm3/h) or (kg air/h)

Pressure As per design

Speed 1500 RPM or below

Noise level Below 85 db at a distance of 1.5 M., from blower

Prime Mover TEFC, horizontal, foot mounted electric motor with class B insulation, IP 55
protection, and suitable for operation on 415 Volts, 50 Hz AC supply. Motor
Shall be Confirming to relevant IS Code

Transmission By set of V belt & Pulleys

Material Of a) Casing: High grade CI hardened and machined on internal Surfaces


Construction
b) Lobes: High Grade CI duly machined and dynamically balanced:

c) Internal Gears: High Grade CI duly Machined

d) Base Frame: Structural Steel Confirming to IS 226

Testing: Blower to be tested for capacity, pressure, power consumption, noise level and
vibration, etc. at vendors shop as per BS 1571. Dynamic Balancing of rotor
and shaft shall be as per ISO 1940.