You are on page 1of 14

Mr. Colonel Balachandran – 3.

04KWp
TECHNICAL SITE VISIT REPORT (3.04 KWp)

Ecosoch Team: Contact Person


Site Visit By:
1) Bhyresh – 9738189157 Mr. Balachandran: 9880599688

EcoSoch Office: #1443, B-Block, Railway Parallel Site Address :#61, Pocket 1, AWHO Vasant
Rd, B Block, CQAL Layout, Sahakar Nagar, Vihar, Bangalore, Karnataka - 562157.
Bengaluru, Karnataka 560092
Coordinates: 13.156966, 77.638000

Technical Site Visit (TSV) Date: 20/03/2020

www.ecosoch.com
1
Solar PV Layout Design

System Type ON-Grid with


Optimizer
Panel Capacity 380Wp
Make Waaree
Number of Panel 8
Inverter Enphase IQ7+
Number of Inverter 8
System Capacity 3.04 KWp
Mounting Structure Jurchen structure

PROPOSED PV DESIGN LAYOUT

2
Proposed PV Area (Roof Image)

3
Solar PV Layout Design (Isometric view)

4
PV Mounting layout

5
Measurement at Sheet roof edges

6
AC Cable & Earthing Route

We have to make hole for the Slab to take


Earthing rod out the AC cable and Earthing rod.

AC Cable (2C 4SQmm) routing from West


side of sheet roof to Ground floor

7
AC & Earthing cable Inter connection point

AC cable and Earthing rod from Rooftop to Car parking area through on west side of wall of the building.

8
AC Cable route at Car parking & Front side of Building

9
Meter Cubicle location

Solar Meter cubicle should be embedded into wall and aligned with this existing Meter box

10
Earthing Location

Earth pit location is identified at Car parking area

11
Solar & Existing meter Box Dimension
1050 mm
450mm

450mm
Space for Solar Meter Existing meter
and accessories Box

600 mm

600 mm 450 mm 50 mm

Envoy-S
200 mm
Solar Meter

450mm
50 mm

Contactor
Contactor

OVCD
MCB

SPD
MCB
100 mm
150 mm
50 mm 50 mm 50 mm 300 mm 50 mm

12
Summary:
• Total Height of Building is 8 Mtrs (Roof on which solar panels to be placed).
• BESCOM meter is located at Ground floor.
• Earthing pit is identified at Car parking area.
• Solar Meter cubicle should be embedded into wall and aligned with this existing Meter box, chipping/civil
work should be outsourced electrician/mason who is doing similar work at a neighboring villa.
• Jurchen type of structure will be using to mount the solar panels.
• AC cable length = 35 Mtrs.
• Earthing conductor length = 35 Mtrs.

13
THANK YOU FOR PARTNERING WITH US

PLEASE VISIT OUR SITE FOR MORE INFORMATION ON SOLAR ROOFTOP SOLUTIONS

www.ecosoch.com
#1443, B Block, Railway Parallel Road, Sahakar Nagar, Bengaluru 560092
CONTACT US: +91-8123410101, 080-41677484

14

You might also like