You are on page 1of 40

AC TRAINING

CONTENT :

 Refrigeration cycle.
 Data Sheet.
 AC Types.
 Refrigerant Types.
 Units Selection @ Ambient Temperature.
 EER Calculation.
 Inverter.
 VRF System.
REFRIGERATION CYCLE

 Compressor.
 Condenser.
 Expansion Valve .
 Evaporator
REFRIGERATION CYCLE
REFRIGERATION CYCLE
COMPRESSOR
COMPRESSOR TYPES:
1- Reciprocating ( Piston ).
2- Rotary.
3- Scroll.
4- Screw.
5- Centrifugal.
CONDENSER:
EXPANSION VALVE
EVAPORATOR
DATA SHEET
AC TYPES
RAC CAC
1- Hi Wall 1- VRF/VRV System
2- Concealed. 2- Package Unit.
3- Window. 3- Chiller
4- Free Stand. - AHU
5- Cassette. - FCU
HI WALL UNIT
CONCEALED UNIT
WINDOW AC
FREE STAND AC
CASSETTE AC
VRF SYSTEM
PACKAGE UNIT
CHILLER
AHUS & FCU
REFRIGERANT TYPES.
AMBIENT TEMPERATURE
 T1: 35 C.
 T3: 46 C.

Required CC Actual Total CC (Btu/h) Actual Total CC (Btu/h)


Units Type Fan Speed Amb. Temp C Selected Model
(Btu/h) @ 27c Ind. & 35c Amb. @ 27c Ind. & 41c Amb.

YEGE18BXEGAH-WX / YEGE18BYEGAHO-X 16238


CONCEALED 15,709 Med 41 15237
YEGE24BXEGAH-WX / YEGE24BYEGAHO-X 21355
CONCEALED 15,709 Med 41 19612
YEGE24BXEGAH-WX / YEGE24BYEGAHO-X 21355
CONCEALED 20,490 Med 41 19612
YEGE36BXEGAH-WX / YEGE36BYEGAHO-X 30310
CONCEALED 20,490 Med 41 31003
YEGE36BXEGAH-WX / YEGE36BYEGAHO-X 30310
CONCEALED 25,271 Med 41 31003
YEGE36BXEGAH-WX / YEGE36BYEGAHO-X 30310
CONCEALED 30,394 Med 41 31003
YEGE36BXEGAH-WX / YEGE36BYEGAHO-X 30310
CONCEALED 32,443 Med 41 31003
YEGE48BXEGAH-WX / YEGE48BYOGAHO-X 40363
CONCEALED 32,443 Med 41 39762
EER CALCULATION
EER=
Cooling Capacity Per BTU/h
Power Input Per w

Example :
Hi Wall 12,000 BTU with Power
Input 1.081 Kw.
EER: 12000/1081=11.10
INVERTER TECHNOLOGY
INVERTER TECHNOLOGY
1- VRF MEANING.
VRF MECHANISM.
VRF MECHANISM.

 Variable Refrigerant Flow (VRF) systems


consist of outdoor units connected to
multiple indoor units via refrigerant
piping to provide cooling and heating
to individual zones. The outdoor units
can modulate capacity based on the
requirements of the individual zones.
3- VRF OUTDOORS .
3- VRF OUTDOORS .
 DVM S systems are designed to operate
from 120°F (49°C) ambient to as low as -
13°F (-25°C).
 WideRange Of Capacities to cover all
Requirements .
 Can
Connected up to 4 Modules ,3
Modules , 2 Modules or 1 Module .
4- VRF INDOORS .
4- VRF INDOORS .

1- HI WALL.
2- SLIM DUCT SPLIT.
3- MEDIUM STATIC DUCT SPLIT.
4- HIGH STATIC DUCT SPLIT.
5- CASSETTE TYPE.
6- FLOOR CEILING.
5- VRF ECO .
The VRF-based Samsung DVM S Eco system air conditioner
combines world-class energy efficiency and economy to deliver
outstanding performance in a space-saving design. Supporting
up to nine indoor units, DVM S Eco is a perfectly optimized cooling
system for residences and smaller buildings. Its lightweight, small-scale
build enables easy, low-cost installation, while its uniquely
quiet design ensures soothing comfort and maximum efficiency.
Plus, the DVM S Eco line offers a wide range of capacities to suit
every need.
5- VRF ECO .
5- VRF ECO .
6- VRF MAIN FEATURES.
1- Space Saving.
2- More choice of capacity, even less cost.
3- Advanced performance & energy
efficiency.
4- Install flexibly with extended pipe length and
elevation.
5- Monitor and resolve system issues remotely
with a
smart management system.
6- A wide range of outdoor temperatures
comfortably.
7- Control your cooling anywhere.
8- Refrigerant pump-down and pump-out.
9- Selection Software.
6- VRF MAIN FEATURES.
6- VRF MAIN FEATURES.
6- VRF MAIN FEATURES.

You might also like