1 PERSONNEL
Contractor shall provide qualified and experienced personnel Contractor shall provide qualified and experienced personnel
sufficient in number and with appropriate qualifications to sufficient in number and with appropriate qualifications to
maintain and operate the H2S Detection Equipment and maintain and operate the H2S Detection Equipment and
Services on site, and process and interpret data as required. A Services on site, and process and interpret data as required. A
standard crew will comprise one (1) H2S Safety Engineer. For 24 standard crew will comprise one (1) H2S Safety Engineer. For 24
hour operations two (2) crews will be required. hour operations two (2) crews will be required.
a. H2S Safety Engineer shall have minimum 5 (five) years a. H2S Safety Engineer shall have minimum 5 (five) years
of oil industry H2S Safety, plus a minimum of 2 (two) of oil industry H2S Safety, plus a minimum of 2 (two)
years of geothermal drilling operations experience. years of geothermal drilling operations experience.
H2S Safety Engineer shall also have extensive H2S Safety Engineer shall also have extensive
knowledge of H2S safety equipment operations, knowledge of H2S safety equipment operations,
materials and products procedures; and experience in materials and products procedures; and experience in
conducting H2S and SCBA training and emergency conducting H2S and SCBA training and emergency
drills. drills.
(see Document CV engineer)
2 EQUIPMENT
Contractor shall provide the required H2S Detection System Contractor shall provide the required H2S Detection System
equipment on an as required basis, and shall be responsible for equipment on an as required basis, and shall be responsible for
mobilisation and demobilisation of this equipment to and from mobilisation and demobilisation of this equipment to and from
the drilling site as required. The list of H2S Detection Equipment the drilling site as required. The list of H2S Detection Equipment
to be provided, as a minimum: to be provided, as a minimum:
a. 1 set of Fixed Point Electronic H2S Gas Detection a. Schneider Electronic Inc. Fixed Point Electronic H2S
System detection/monitoring system w/ capabilities of
monitoring 4-6 areas around the location.
(see Fergaco Equipment Spec. Page 1)
b. 6 sets for 4 areas of Hydrogen Sulphide Sensor b. Industrial Scientific Inc. iTrans-Explosion proof H2S fix
(measuring range: 0-100 ppm, explosion proof, and sensor (Toxic Electrochemical) measuring ranges : 0-
impervious to high moisture environments.) 500 ppm in 1 ppm increments
(see Fergaco Equipment Spec. Page 2-3)
ITEM H2S DETECTION EQUIPMENT AND SERVICES SPECIFICATIONS CONTRACTOR’S RESPONSE
c. Hydrogen Sulphide Calibration System c. Industrial Scientific Inc. CAL-Gaz Complete set Gas
cylinder for calibration kit contains of mixing gases :
H2S, LEL, CO, O2 c/w regulator.
(see Fergaco Equipment Spec. Page 4 )
d. 3 sets of Strobe Light and Siren System d. Tomar Electronic Inc. Explosion proof H2S alarm
consisting of mounting frame, pole, one amber strobe
light and one alternating yelp tone siren.
(see Fergaco Equipment Spec. Page 5-6 )
e. 8 sets of 30-minute positive Self-Contained Breathing e. Scott Industrial Inc. AP-50 Self Contained Breathing
Apparatus (SCBA) for rescue unit rated to NIOSH Apparatus (SCBA) c/w hose line attachment,
standard. w/cylinder pressure 2216 psi, NIOSH/MSHA approval
(see Fergaco Equipment Spec. Page 7 )
g. 8 sets of Workline Unit Complete Cascade System g. Scott Industrial Inc. Ska Pak 5 minute entry/egress
cylinder Supplied Air Breathing Apparatus (SABA) c/w
weather proof storage stainless steel box. These air
packs are NIOSH/MSHA Approval. Complete Cascade
System
(see Fergaco Equipment Spec. Page 9-10 )
h. 1 ea of Oxygen Powered Resuscitators
h. Life Support Products Inc. Oxygen Powered
Resuscitators
(see Fergaco Equipment Spec. Page 11)