You are on page 1of 11

LST OTHSOFTPARA:LSTFORMAT=VERTICAL;

BKMBSC15
+++ HWBSC6910 2019-06-25 16:16:27
O&M #2588490
%%/*8352875*/LST OTHSOFTPARA: LSTFORMAT=VERTICAL;%%
RETCODE = 0 Execution succeeded.

List Other Software Parameters of BSC


-------------------------------------
Support Auto Obtaining of BTS Logs = No
Auto Check of BTS Connection Port = Yes
Support Sent 2QUATER = Yes
Send 3G Class Flag = Yes
Support NR_of_FDD_cells Writing = Yes
Record Discarded Paging Msg = No
Disconnect Handover Protect Timer = 3
Response on Out-BSC HO Req = Yes
ResCheckAllowed = Yes
SI 2ter Switch = Yes
BTS Reset Alarm Delay Switch = No
BTS Reset Alarm Delay Time = 5
Relative Signal Strength Threshold = 68
Absolute Signal Strength Threshold = 30
Abnormal Voice MOS Threshold = 100
Support End-to-end User Tracing Function = No
A Interface Msg [End2end User Tracing] = <NULL>
Spt BSS Invoke Trace Rpt[end2end user trace] = <NULL>
Support Half Rate Data Service = No
Immediately Allocate TCHs to MOC = No
Immediately Allocate TCHs to MTC = No
Classmark Enquiry With 3G Request = No
NeighborCell Interfere Level Thresh 0 = 0
NeighborCell Interfere Level Thresh 1 = 61
NeighborCell Interfere Level Thresh 2 = 64
NeighborCell Interfere Level Thresh 3 = 67
NeighborCell Interfere Level Thresh 4 = 70
NeighborCell Interfere Level Thresh 5 = 73
NeighborCell Interfere Level Thresh 6 = 76
NeighborCell Interfere Level Thresh 7 = 79
TCH Rate Modify = Yes
Send System Information 2ter = No
Send System Information 5ter = Yes
eMLPP Priority In Paging = No
TER Indicator of System Information 3 = Yes
CM3 Change in Paging Response = 3
CM Update Optimize Type = 0
Discard TMSI All Cell Paging = Close
Reserved parameter 3 = 65535
Reserved parameter 6 = 2
Reserved parameter 8 = 0
Reserved parameter 20 = 0
Reserved parameter 21 = 0
RAI Alarm Switch = No
Send Downlink Message after Hanging up = Yes
Service Based Handover Switch = Close
Service Handover Reassign = No
Max BTS Num of Parallel Software Load = 100
Jitter Buffer switch = Deny
LAPD Window Adjust Switch = Deny
IBCA Info Report Period Within BSC = 2000
IBCA Info Report Period Between BSC = 4000
Hop Group Single Freq Optimization = Off
CS 2G 3G Load Balance Delta Threshold = 110
OML Lapd Link Detect Time = 10
Neighboring 3G Cell Threshold 1 = 25
Neighboring 3G Cell Threshold 2 = 20
Neighbor 3G Cell Measurement Threshold 0 = -47dBm
Neighbor 3G Cell Measurement Threshold 1 = -105dBm
Neighbor 3G Cell Measurement Threshold 2 = 0dB
Preemption Allowed = Yes
Queue Allowed = Yes
Preemption Allowed During Intra-BSC Handover = No
Queuing Allowed During Intra-BSC Handover = No
eMLPP Multi-Priority Classes Allowed = Yes
PDCH Preemption Allowed During Handover Due to Preemption = Not Allowed
Highest-Priority MSs Rapid Preemption = No
Preempted Call Not Released After Handover Failure = No
MOCN Switch = Close
Re-Routing Occasion = Not Redirect
Filter CS Based on Operator Neighboring Cell List = No
Filter PS Based on Operator Neighboring Cell List = No
IMSI Handover Switch = No
Inter-BSC Better Cell HO Preemption Allowed = Allowed
IBCA Flow Control Period = 100
Thres. of Evaluation Times in IBCA FC = 100
Downlink DTMF Signaling Processing Allowed = Close
Required Auto Mute SAIC Identify Times = 100
Required Times for Identifying Mute SAIC = 40
Times for Identify Problem SAIC Terminal = 200
Problem SAIC Terminal Identify Threshold = 120
Upper Alpha Thres for Mute SAIC Identify = 16
Lower Alpha Thres for Mute SAIC Identify = 6
Whether to optimize CA Frequency Allocation Mode = No
Optimize Adjustment of Configured Channel Type = Close
Threshold of Short-Time Call Duration = 10
Calculate Number of Failed Assignments = Close
Delay Sending Handover Command = Close
Timer of Delay Sending Handover Command = 200
Send Speech Version in Advance = Open
Report FR Capability on Cell Congestion = Yes
Data Rate Change in New Handovers = No
Dyn Measurement on a Non-IBCA Neighbor = NO
Support VIP User = OFF
TCH Busy Threshold for VIP User = 80
OUT-BSC HoReqMsg Include VIP Info Switch = OFF
GBTS CHR MSISDN = ####
Non-Counting Period of NCELL Counter = 3
MSC Abnormal Release Stat SDCCH Drop = Yes
MSC Abnormal Release Stat TCH Drop = No
Access Cause Statistics Optimization Sw = OFF
TA Limit Drop Statistics Optimization Sw = OFF
Non-Call Immediate Ass Stat Opt Sw = OFF
Queue In Assignment Optimization Stat = Yes
Successful Inter-RAT Incoming BSC HO Stat = ON
Neighboring Cell Format in CHR MR = Bcch Index
CSD Outgoing BSC HO Failure Stat = NO
UMTS Source Cell Identification Optimization = ON
Low Level Optimization for UL-to-OL Handover = ON
Stat. Optimization of Failed Incoming BSC HO = OFF
Equipment Fail Call Drop Stat. Optimize = OFF
TRX Availability Determining Optimization = ON
N(U) in Attach Request = 512
PDCH-to-TCH Adjustment = OFF
Difference Compensated for Time Stamp = ON
Handover II Reorder After K Sorting = OFF
Out-BSC HO Request Stat. Adjust Policy = ON
Radio Link Abnormal TA Measurement Optimize = OFF
Iur-g Load and Capacity Calculation = OFF
Internal Fault-Related KPI Measurement = OFF
TCH Busy Duration Measurement Optimize = OFF
Radio Data Report for Navigation in Advance = OFF
Voice Problem Auto Trace = Off
Inter-RAT Cell Reselection Optimization = On
Neighbor Cell Output Mode in MR = BCCH Index
Call Re-setup Timeout Call Drop Stat. Optimize = No
Incoming BSC HO Emergency Call Guarantee = No
MSC Reallocation Optimization = No
Fast Reselection During Location Update = No
Abis Territorial Link Fault Call Drop Stat = ON
Out-BSC HO Failure Stat. Policy = Off
DTM CS Handover Optimization = No
DTM Combined Update Optimize Type = RAU ACC Send Delay
Faulty EMR MS Detection Count Threshold = 1
EMR MS Detection Count Threshold = 10
MOCN XID Reset Policy = Requery IMSI Send
MAX Retrans Reset Circle Msg on A-I = 2
Support Apply Used A Cic = Yes
Enable TC Performance Measurement = No
TC Performance Measurement Type = TFO Measurement::OFF
= ANC Measurement::OFF
= ANR Measurement::OFF
= AEC Measurement::OFF
= ACLP Measurement::OFF
= ALC Measurement::OFF
Message Usage = 85
FlexAbis Timeslot Preempt Optimize Switch = OFF
(Number of results = 1)

--- END

LST OTHSOFTPARA:LSTFORMAT=VERTICAL;
GBMBSC14
+++ HWBSC6910 2019-06-25 16:16:27
O&M #2118749
%%/*8352874*/LST OTHSOFTPARA: LSTFORMAT=VERTICAL;%%
RETCODE = 0 Execution succeeded.

List Other Software Parameters of BSC


-------------------------------------
Support Auto Obtaining of BTS Logs = No
Auto Check of BTS Connection Port = Yes
Support Sent 2QUATER = Yes
Send 3G Class Flag = Yes
Support NR_of_FDD_cells Writing = Yes
Record Discarded Paging Msg = No
Disconnect Handover Protect Timer = 3
Response on Out-BSC HO Req = Yes
ResCheckAllowed = Yes
SI 2ter Switch = Yes
BTS Reset Alarm Delay Switch = No
BTS Reset Alarm Delay Time = 5
Relative Signal Strength Threshold = 68
Absolute Signal Strength Threshold = 30
Abnormal Voice MOS Threshold = 100
Support End-to-end User Tracing Function = No
A Interface Msg [End2end User Tracing] = <NULL>
Spt BSS Invoke Trace Rpt[end2end user trace] = <NULL>
Support Half Rate Data Service = No
Immediately Allocate TCHs to MOC = No
Immediately Allocate TCHs to MTC = No
Classmark Enquiry With 3G Request = No
NeighborCell Interfere Level Thresh 0 = 0
NeighborCell Interfere Level Thresh 1 = 61
NeighborCell Interfere Level Thresh 2 = 64
NeighborCell Interfere Level Thresh 3 = 67
NeighborCell Interfere Level Thresh 4 = 70
NeighborCell Interfere Level Thresh 5 = 73
NeighborCell Interfere Level Thresh 6 = 76
NeighborCell Interfere Level Thresh 7 = 79
TCH Rate Modify = Yes
Send System Information 2ter = No
Send System Information 5ter = Yes
eMLPP Priority In Paging = No
TER Indicator of System Information 3 = Yes
CM3 Change in Paging Response = 3
CM Update Optimize Type = 0
Discard TMSI All Cell Paging = Close
Reserved parameter 3 = 65535
Reserved parameter 6 = 2
Reserved parameter 8 = 0
Reserved parameter 20 = 0
Reserved parameter 21 = 0
RAI Alarm Switch = No
Send Downlink Message after Hanging up = Yes
Service Based Handover Switch = Close
Service Handover Reassign = No
Max BTS Num of Parallel Software Load = 100
Jitter Buffer switch = Deny
LAPD Window Adjust Switch = Deny
IBCA Info Report Period Within BSC = 2000
IBCA Info Report Period Between BSC = 4000
Hop Group Single Freq Optimization = Off
CS 2G 3G Load Balance Delta Threshold = 110
OML Lapd Link Detect Time = 10
Neighboring 3G Cell Threshold 1 = 25
Neighboring 3G Cell Threshold 2 = 20
Neighbor 3G Cell Measurement Threshold 0 = -47dBm
Neighbor 3G Cell Measurement Threshold 1 = -105dBm
Neighbor 3G Cell Measurement Threshold 2 = 0dB
Preemption Allowed = Yes
Queue Allowed = Yes
Preemption Allowed During Intra-BSC Handover = No
Queuing Allowed During Intra-BSC Handover = No
eMLPP Multi-Priority Classes Allowed = Yes
PDCH Preemption Allowed During Handover Due to Preemption = Not Allowed
Highest-Priority MSs Rapid Preemption = No
Preempted Call Not Released After Handover Failure = No
MOCN Switch = Close
Re-Routing Occasion = Not Redirect
Filter CS Based on Operator Neighboring Cell List = No
Filter PS Based on Operator Neighboring Cell List = No
IMSI Handover Switch = No
Inter-BSC Better Cell HO Preemption Allowed = Allowed
IBCA Flow Control Period = 100
Thres. of Evaluation Times in IBCA FC = 100
Downlink DTMF Signaling Processing Allowed = Close
Required Auto Mute SAIC Identify Times = 100
Required Times for Identifying Mute SAIC = 40
Times for Identify Problem SAIC Terminal = 200
Problem SAIC Terminal Identify Threshold = 120
Upper Alpha Thres for Mute SAIC Identify = 16
Lower Alpha Thres for Mute SAIC Identify = 6
Whether to optimize CA Frequency Allocation Mode = No
Optimize Adjustment of Configured Channel Type = Close
Threshold of Short-Time Call Duration = 10
Calculate Number of Failed Assignments = Close
Delay Sending Handover Command = Close
Timer of Delay Sending Handover Command = 200
Send Speech Version in Advance = Open
Report FR Capability on Cell Congestion = Yes
Data Rate Change in New Handovers = No
Dyn Measurement on a Non-IBCA Neighbor = NO
Support VIP User = OFF
TCH Busy Threshold for VIP User = 80
OUT-BSC HoReqMsg Include VIP Info Switch = OFF
GBTS CHR MSISDN = ####
Non-Counting Period of NCELL Counter = 3
MSC Abnormal Release Stat SDCCH Drop = Yes
MSC Abnormal Release Stat TCH Drop = No
Access Cause Statistics Optimization Sw = OFF
TA Limit Drop Statistics Optimization Sw = OFF
Non-Call Immediate Ass Stat Opt Sw = OFF
Queue In Assignment Optimization Stat = Yes
Successful Inter-RAT Incoming BSC HO Stat = ON
Neighboring Cell Format in CHR MR = Bcch Index
CSD Outgoing BSC HO Failure Stat = NO
UMTS Source Cell Identification Optimization = ON
Low Level Optimization for UL-to-OL Handover = ON
Stat. Optimization of Failed Incoming BSC HO = OFF
Equipment Fail Call Drop Stat. Optimize = OFF
TRX Availability Determining Optimization = ON
N(U) in Attach Request = 512
PDCH-to-TCH Adjustment = OFF
Difference Compensated for Time Stamp = ON
Handover II Reorder After K Sorting = OFF
Out-BSC HO Request Stat. Adjust Policy = ON
Radio Link Abnormal TA Measurement Optimize = OFF
Iur-g Load and Capacity Calculation = OFF
Internal Fault-Related KPI Measurement = OFF
TCH Busy Duration Measurement Optimize = OFF
Radio Data Report for Navigation in Advance = OFF
Voice Problem Auto Trace = Off
Inter-RAT Cell Reselection Optimization = On
Neighbor Cell Output Mode in MR = BCCH Index
Call Re-setup Timeout Call Drop Stat. Optimize = No
Incoming BSC HO Emergency Call Guarantee = No
MSC Reallocation Optimization = No
Fast Reselection During Location Update = No
Abis Territorial Link Fault Call Drop Stat = ON
Out-BSC HO Failure Stat. Policy = Off
DTM CS Handover Optimization = No
DTM Combined Update Optimize Type = RAU ACC Send Delay
Faulty EMR MS Detection Count Threshold = 1
EMR MS Detection Count Threshold = 10
MOCN XID Reset Policy = Requery IMSI Send
MAX Retrans Reset Circle Msg on A-I = 2
Support Apply Used A Cic = Yes
Enable TC Performance Measurement = No
TC Performance Measurement Type = TFO Measurement::OFF
= ANC Measurement::OFF
= ANR Measurement::OFF
= AEC Measurement::OFF
= ACLP Measurement::OFF
= ALC Measurement::OFF
Message Usage = 85
FlexAbis Timeslot Preempt Optimize Switch = OFF
(Number of results = 1)

--- END

LST OTHSOFTPARA:LSTFORMAT=VERTICAL;
KOMBSC16
+++ HWBSC6910 2019-06-25 16:16:27
O&M #2193059
%%/*8352876*/LST OTHSOFTPARA: LSTFORMAT=VERTICAL;%%
RETCODE = 0 Execution succeeded.

List Other Software Parameters of BSC


-------------------------------------
Support Auto Obtaining of BTS Logs = No
Auto Check of BTS Connection Port = Yes
Support Sent 2QUATER = Yes
Send 3G Class Flag = Yes
Support NR_of_FDD_cells Writing = Yes
Record Discarded Paging Msg = No
Disconnect Handover Protect Timer = 3
Response on Out-BSC HO Req = Yes
ResCheckAllowed = Yes
SI 2ter Switch = Yes
BTS Reset Alarm Delay Switch = No
BTS Reset Alarm Delay Time = 5
Relative Signal Strength Threshold = 68
Absolute Signal Strength Threshold = 30
Abnormal Voice MOS Threshold = 100
Support End-to-end User Tracing Function = No
A Interface Msg [End2end User Tracing] = <NULL>
Spt BSS Invoke Trace Rpt[end2end user trace] = <NULL>
Support Half Rate Data Service = No
Immediately Allocate TCHs to MOC = No
Immediately Allocate TCHs to MTC = No
Classmark Enquiry With 3G Request = No
NeighborCell Interfere Level Thresh 0 = 0
NeighborCell Interfere
Level Thresh 1 = 61
NeighborCell Interfere
Level Thresh 2 = 64
NeighborCell Interfere
Level Thresh 3 = 67
NeighborCell Interfere
Level Thresh 4 = 70
NeighborCell Interfere
Level Thresh 5 = 73
NeighborCell Interfere
Level Thresh 6 = 76
NeighborCell Interfere
Level Thresh 7 = 79
TCH Rate Modify = Yes
Send System Information 2ter = No
Send System Information 5ter = Yes
eMLPP Priority In Paging = No
TER Indicator of System Information 3 = Yes
CM3 Change in Paging Response = 3
CM Update Optimize Type = 0
Discard TMSI All Cell Paging = Close
Reserved parameter 3 = 65535
Reserved parameter 6 = 2
Reserved parameter 8 = 0
Reserved parameter 20 = 0
Reserved parameter 21 = 0
RAI Alarm Switch = No
Send Downlink Message after Hanging up = Yes
Service Based Handover Switch = Close
Service Handover Reassign = No
Max BTS Num of Parallel Software Load = 100
Jitter Buffer switch = Deny
LAPD Window Adjust Switch = Deny
IBCA Info Report Period Within BSC = 2000
IBCA Info Report Period Between BSC = 4000
Hop Group Single Freq Optimization = Off
CS 2G 3G Load Balance Delta Threshold = 110
OML Lapd Link Detect Time = 10
Neighboring 3G Cell Threshold 1 = 25
Neighboring 3G Cell Threshold 2 = 20
Neighbor 3G Cell Measurement Threshold 0 = -47dBm
Neighbor 3G Cell Measurement Threshold 1 = -105dBm
Neighbor 3G Cell Measurement Threshold 2 = 0dB
Preemption Allowed = Yes
Queue Allowed = Yes
Preemption Allowed During Intra-BSC Handover = No
Queuing Allowed During Intra-BSC Handover = No
eMLPP Multi-Priority Classes Allowed = Yes
PDCH Preemption Allowed During Handover Due to Preemption = Not Allowed
Highest-Priority MSs Rapid Preemption = No
Preempted Call Not Released After Handover Failure = No
MOCN Switch = Close
Re-Routing Occasion = Not Redirect
Filter CS Based on Operator Neighboring Cell List = No
Filter PS Based on Operator Neighboring Cell List = No
IMSI Handover Switch = No
Inter-BSC Better Cell HO Preemption Allowed = Allowed
IBCA Flow Control Period = 100
Thres. of Evaluation Times in IBCA FC = 100
Downlink DTMF Signaling Processing Allowed = Close
Required Auto Mute SAIC Identify Times = 100
Required Times for Identifying Mute SAIC = 40
Times for Identify Problem SAIC Terminal = 200
Problem SAIC Terminal Identify Threshold = 120
Upper Alpha Thres for Mute SAIC Identify = 16
Lower Alpha Thres for Mute SAIC Identify = 6
Whether to optimize CA Frequency Allocation Mode = No
Optimize Adjustment of Configured Channel Type = Close
Threshold of Short-Time Call Duration = 0
Calculate Number of Failed Assignments = Close
Delay Sending Handover Command = Close
Timer of Delay Sending Handover Command = 200
Send Speech Version in Advance = Open
Report FR Capability on Cell Congestion = Yes
Data Rate Change in New Handovers = No
Dyn Measurement on a Non-IBCA Neighbor = NO
Support VIP User = OFF
TCH Busy Threshold for VIP User = 80
OUT-BSC HoReqMsg Include VIP Info Switch = OFF
GBTS CHR MSISDN = ####
Non-Counting Period of NCELL Counter = 3
MSC Abnormal Release Stat SDCCH Drop = Yes
MSC Abnormal Release Stat TCH Drop = No
Access Cause Statistics Optimization Sw = OFF
TA Limit Drop Statistics Optimization Sw = OFF
Non-Call Immediate Ass Stat Opt Sw = OFF
Queue In Assignment Optimization Stat = Yes
Successful Inter-RAT Incoming BSC HO Stat = ON
Neighboring Cell Format in CHR MR = Bcch Index
CSD Outgoing BSC HO Failure Stat = NO
UMTS Source Cell Identification Optimization = ON
Low Level Optimization for UL-to-OL Handover = ON
Stat. Optimization of Failed Incoming BSC HO = OFF
Equipment Fail Call Drop Stat. Optimize = OFF
TRX Availability Determining Optimization = ON
N(U) in Attach Request = 512
PDCH-to-TCH Adjustment = OFF
Difference Compensated for Time Stamp = ON
Handover II Reorder After K Sorting = OFF
Out-BSC HO Request Stat. Adjust Policy = ON
Radio Link Abnormal TA Measurement Optimize = OFF
Iur-g Load and Capacity Calculation = OFF
Internal Fault-Related KPI Measurement = OFF
TCH Busy Duration Measurement Optimize = OFF
Radio Data Report for Navigation in Advance = OFF
Voice Problem Auto Trace = Off
Inter-RAT Cell Reselection Optimization = Off
Neighbor Cell Output Mode in MR = BCCH Index
Call Re-setup Timeout Call Drop Stat. Optimize = No
Incoming BSC HO Emergency Call Guarantee = No
MSC Reallocation Optimization = No
Fast Reselection During Location Update = No
Abis Territorial Link Fault Call Drop Stat = ON
Out-BSC HO Failure Stat. Policy = Off
DTM CS Handover Optimization = No
DTM Combined Update Optimize Type = RAU ACC Send Delay
Faulty EMR MS Detection Count Threshold = 1
EMR MS Detection Count Threshold = 10
MOCN XID Reset Policy = Requery IMSI Send
MAX Retrans Reset Circle Msg on A-I = 2
Support Apply Used A Cic = Yes
Enable TC Performance Measurement = No
TC Performance Measurement Type = TFO Measurement::OFF
= ANC Measurement::OFF
= ANR Measurement::OFF
= AEC Measurement::OFF
= ACLP Measurement::OFF
= ALC Measurement::OFF
Message Usage = 85
FlexAbis Timeslot Preempt Optimize Switch = OFF
(Number of results = 1)

--- END

LST OTHSOFTPARA:LSTFORMAT=VERTICAL;
YAMBSC12
+++ HWBSC6910 2019-06-25 16:16:27
O&M #4949098
%%/*8352877*/LST OTHSOFTPARA: LSTFORMAT=VERTICAL;%%
RETCODE = 0 Execution succeeded.

List Other Software Parameters of BSC


-------------------------------------
Support Auto Obtaining of BTS Logs = No
Auto Check of BTS Connection Port = Yes
Support Sent 2QUATER = Yes
Send 3G Class Flag = Yes
Support NR_of_FDD_cells Writing = Yes
Record Discarded Paging Msg = No
Disconnect Handover Protect Timer = 3
Response on Out-BSC HO Req = Yes
ResCheckAllowed = Yes
SI 2ter Switch = Yes
BTS Reset Alarm Delay Switch = No
BTS Reset Alarm Delay Time = 5
Relative Signal Strength Threshold = 68
Absolute Signal Strength Threshold = 30
Abnormal Voice MOS Threshold = 100
Support End-to-end User Tracing Function = No
A Interface Msg [End2end User Tracing] = <NULL>
Spt BSS Invoke Trace Rpt[end2end user trace] = <NULL>
Support Half Rate Data Service = No
Immediately Allocate TCHs to MOC = No
Immediately Allocate TCHs to MTC = No
Classmark Enquiry With 3G Request = No
NeighborCell Interfere Level Thresh 0 = 0
NeighborCell Interfere Level Thresh 1 = 61
NeighborCell Interfere Level Thresh 2 = 64
NeighborCell Interfere Level Thresh 3 = 67
NeighborCell Interfere Level Thresh 4 = 70
NeighborCell Interfere Level Thresh 5 = 73
NeighborCell Interfere Level Thresh 6 = 76
NeighborCell Interfere Level Thresh 7 = 79
TCH Rate Modify = Yes
Send System Information 2ter = No
Send System Information 5ter = Yes
eMLPP Priority In Paging = No
TER Indicator of System Information 3 = Yes
CM3 Change in Paging Response = 3
CM Update Optimize Type = 0
Discard TMSI All Cell Paging = Close
Reserved parameter 3 = 65535
Reserved parameter 6 = 2
Reserved parameter 8 = 0
Reserved parameter 20 = 0
Reserved parameter 21 = 0
RAI Alarm Switch = No
Send Downlink Message after Hanging up = Yes
Service Based Handover Switch = Close
Service Handover Reassign = No
Max BTS Num of Parallel Software Load = 100
Jitter Buffer switch = Deny
LAPD Window Adjust Switch = Deny
IBCA Info Report Period Within BSC = 2000
IBCA Info Report Period Between BSC = 4000
Hop Group Single Freq Optimization = Off
CS 2G 3G Load Balance Delta Threshold = 110
OML Lapd Link Detect Time = 10
Neighboring 3G Cell Threshold 1 = 25
Neighboring 3G Cell Threshold 2 = 20
Neighbor 3G Cell Measurement Threshold 0 = -47dBm
Neighbor 3G Cell Measurement Threshold 1 = -105dBm
Neighbor 3G Cell Measurement Threshold 2 = 0dB
Preemption Allowed = Yes
Queue Allowed = Yes
Preemption Allowed During Intra-BSC Handover = No
Queuing Allowed During Intra-BSC Handover = No
eMLPP Multi-Priority Classes Allowed = Yes
PDCH Preemption Allowed During Handover Due to Preemption = Not Allowed
Highest-Priority MSs Rapid Preemption = No
Preempted Call Not Released After Handover Failure = No
MOCN Switch = Close
Re-Routing Occasion = Not Redirect
Filter CS Based on Operator Neighboring Cell List = No
Filter PS Based on Operator Neighboring Cell List = No
IMSI Handover Switch = No
Inter-BSC Better Cell HO Preemption Allowed = Allowed
IBCA Flow Control Period = 100
Thres. of Evaluation Times in IBCA FC = 100
Downlink DTMF Signaling Processing Allowed = Close
Required Auto Mute SAIC Identify Times = 100
Required Times for Identifying Mute SAIC = 40
Times for Identify Problem SAIC Terminal = 200
Problem SAIC Terminal Identify Threshold = 120
Upper Alpha Thres for Mute SAIC Identify = 16
Lower Alpha Thres for Mute SAIC Identify = 6
Whether to optimize CA Frequency Allocation Mode = No
Optimize Adjustment of Configured Channel Type = Close
Threshold of Short-Time Call Duration = 10
Calculate Number of Failed Assignments = Close
Delay Sending Handover Command = Close
Timer of Delay Sending Handover Command = 200
Send Speech Version in Advance = Open
Report FR Capability on Cell Congestion = Yes
Data Rate Change in New Handovers = No
Dyn Measurement on a Non-IBCA Neighbor = NO
Support VIP User = OFF
TCH Busy Threshold for VIP User = 80
OUT-BSC HoReqMsg Include VIP Info Switch = OFF
GBTS CHR MSISDN = ####
Non-Counting Period of NCELL Counter = 3
MSC Abnormal Release Stat SDCCH Drop = Yes
MSC Abnormal Release Stat TCH Drop = No
Access Cause Statistics Optimization Sw = OFF
TA Limit Drop Statistics Optimization Sw = OFF
Non-Call Immediate Ass Stat Opt Sw = OFF
Queue In Assignment Optimization Stat = Yes
Successful Inter-RAT Incoming BSC HO Stat = ON
Neighboring Cell Format in CHR MR = Bcch Index
CSD Outgoing BSC HO Failure Stat = NO
UMTS Source Cell Identification Optimization = ON
Low Level Optimization for UL-to-OL Handover = ON
Stat. Optimization of Failed Incoming BSC HO = OFF
Equipment Fail Call Drop Stat. Optimize = OFF
TRX Availability Determining Optimization = ON
N(U) in Attach Request = 512
PDCH-to-TCH Adjustment = OFF
Difference Compensated for Time Stamp = ON
Handover II Reorder After K Sorting = OFF
Out-BSC HO Request Stat. Adjust Policy = ON
Radio Link Abnormal TA Measurement Optimize = OFF
Iur-g Load and Capacity Calculation = OFF
Internal Fault-Related KPI Measurement = OFF
TCH Busy Duration Measurement Optimize = OFF
Radio Data Report for Navigation in Advance = OFF
Voice Problem Auto Trace = Off
Inter-RAT Cell Reselection Optimization = On
Neighbor Cell Output Mode in MR = BCCH Index
Call Re-setup Timeout Call Drop Stat. Optimize = No
Incoming BSC HO Emergency Call Guarantee = No
MSC Reallocation Optimization = No
Fast Reselection During Location Update = No
Abis Territorial Link Fault Call Drop Stat = ON
Out-BSC HO Failure Stat. Policy = Off
DTM CS Handover Optimization = No
DTM Combined Update Optimize Type = RAU ACC Send Delay
Faulty EMR MS Detection Count Threshold = 1
EMR MS Detection Count Threshold = 10
MOCN XID Reset Policy = Requery IMSI Send
MAX Retrans Reset Circle Msg on A-I = 2
Support Apply Used A Cic = Yes
Enable TC Performance Measurement = No
TC Performance Measurement Type = TFO Measurement::OFF
= ANC Measurement::OFF
= ANR Measurement::OFF
= AEC Measurement::OFF
= ACLP Measurement::OFF
= ALC Measurement::OFF
Message Usage = 85
FlexAbis Timeslot Preempt Optimize Switch = OFF
(Number of results = 1)

--- END

You might also like