You are on page 1of 4

Technical Data Sheet

Tangit PVC-C

I. Material
Product name: Intended use: Packaging:
Tangit PVC-C special adhesive Tangit PVC-C is suitable for 700 g tin
producing tensile stress resistant
Material type: connections between pipes and Shipping unit:
Solvent-containing adhesive PVC-C fittings for industrial and 6 tins of 700 g
based on tetrahydrofuran sanitary use (DVGW test mark TS
(THF stabilized). 232 in conjunction with the
Dekadur C piping system).

II. Special Features

Technical data

• Tangit PVC-U complies with Raw material basis: Viscosity:


the requirements of EN 14814, PVC-C, tetrahydrofuran, methyl 1700-3000 mPas, determined by
Adhesives for thermoplastic ethyl ketone, cyclohexanone. the Drage/Epprecht method,
piping systems for fluids under measuring body 3 at 23ºC
pressure. Density (spec. gravity): 8000-15000 mPas Brookfield,
• Tangit PVC-C complies with approx. 0.97 g/ml LVT spindle 4 / 30 rpm at 23ºC.
the requirements of DIN 16970
for bonded joints. Temperature resistance:
• Tangit meets the thermal and
strength requirements for Depends on the application
industrial and sanitary use. (industry/sanitation) and on the
resulting maximal pressure load.

Resistibility:
The bonded joints are waterproof.
Their chemical resistance,
especially to inorganic acids,
depends on pipe tolerances,
curing times, pressure loads,
operation temperatures, acid type
and acid concentration.
Consumption:
For the production of 100 bonded joints the following approximate amounts of adhesive and cleaner are
required:

Outer pipe
20 25 32 40 50 63 75 90 110 140
diameter (mm)

Tangit PVC-C
0.3 0.4 0.5 0.7 0.9 1.1 1.3 1.4 1.7 2.1
adhesive (kg)

Tangit Cleaner
0.5 0.6 0.8 1.1 1.5 1.7 2.2 4.0 8.0 13.0
(kg)

Please note: The adhesive amounts indicated above are maximum values based on practical experience.
The actual consumption in a given application depends on working method, pipe gap and temperature.

III. Instructions for use


Preparation of the surfaces to
be bonded:
Cut pipe
If pipe ends and sockets have right-angled
not yet been prepared according
to the illustrations below, they
must be chamfered and
Bevel-cut
deburred.
outside,
No tight and durable bonding deflash
can be achieved unless pipes inside
have been properly chamfered.
Measure b in Plug-in Depth in
Pretreatment: Pipe Outer Pipe Outer
Diameter (mm)
mm, application mm
with fittings Diameter (mm)
Remove heavy dirt adherent to t
the surfaces to be bonded (pipe up to 16 approx. 2
end outside, socket inside). 20 – 50 approx. 3 16 14
63 – 225 approx. 5 20 16
Final cleaning (removal of
25 19
lubricant and partial dissolution 32 22
of the surfaces) is done using 40 26
Tangit Cleaner and tissue 50 31
paper. Then measure the fitting 63 38
insertion depth (= bond length) 75 44
and mark it on the pipe end so 90 51
that the application of the 110 61
required amount of adhesive 140 76
160 86
and the complete insertion of
225 118,5
the pipe can be checked.
Spray Tangit Cleaner onto
pieces of white soft paper, e.g. An indication that insufficient
The PVC-C pipeline components
tissue paper, and thoroughly bonding is to be expected is the
currently in the market usually
clean the dry surfaces to be failing or insufficient partial
have a good bonding behaviour. In
bonded. Use a new piece of dissolution of the pipe surfaces to
some cases, especially after
tissue paper for each cleaning be fitted after cleaning with Tangit
prolonged UV exposure,
operation. The cleaned surfaces Cleaner (use fingernail to check).
mechanical treatment of the pipe
must be dry before applying the In such cases, the surfaces must
surface may be necessary.
adhesive. Any ice must be be uniformly roughened using
removed by careful heating. abrasive cloth (grit 80 or finer),
observing the maximum gaps
allowed.
Application: As the adhesive cures rapidly, the Pressure tests and filling:
Stir Tangit PVC-C well before components must be completely During the first 10 minutes after
use. The adhesive should flow joined within 1 min after bonding, the pipes must not be
slowly off a stick held at an angle, application. From DN 65 upwards, moved. At temperatures below
forming a trail. In an axial the adhesive should be applied to +10°C, this time must be
direction apply a uniform coat of pipe and socket simultaneously extended to at least 30 minutes.
adhesive - first to the inside of the by two persons. If pipes of > 140 Wait 24 hours after the last
socket, then to the pipe. Apply mm OD are to be bonded, bonding before filling the pipelines
thinly inside the socket in order to dimensional selection of pipes or performing leak tests.
avoid the detrimental formation of and pipeline components should
ensure a maximum tolerance The following values can be used
beads inside the pipe, but apply
(gap) of +0.6 mm for the as reference for the thermal and
generously to the pipe end.
diameters of pipe and socket. pressure stability reached after 24
Recommended brush sizes: hours drying (gap +0.2 mm):
up to DN 32 = 8 mm round brush The open time of Tangit PVC-C,
i.e. the time from the start of 20°C = 24 bar
DN 32-50 = 1"-flat brush
adhesive application until joining 50°C = 12 bar
DN 65-125 = 2"-flat brush
the parts, depends on ambient 60°C = 9 bar
Immediately insert the pipe into temperature and/or film thickness 70°C = 7 bar
the socket to stop resp. to full of the applied adhesive. 80°C = 3 bar
depth, without twisting or
jamming. Hold fast for several
seconds until the adhesive begins
to dry. Then remove excess
adhesive with tissue paper.

IV. Special instructions

General information: Installation: Please note:


Before start of operation, pipe- Installation at low temperatures The installation of pressure pipes
lines must be carefully flushed in requires utmost care. At tempera- and fittings made of PVC-C
order to remove residual solvent tures below +5ºC, pipes and requires expertise in the use of
vapours. Tangit PVC-C is ready fittings tend to be more vulnerable these materials. The instructions
for use and must under no to impact (embrittlement) so that given here are therefore only
circumstances be diluted. long-term exposure to solvent meant to support well-trained staff
vapours may result in damage to in their work. Please make sure to
Tangit PVC-C and Tangit Cleaner the system. Since Tangit PVC-C observe the installation instruc-
affect PVC-C. Pipes and fittings cures physically by evaporation, tions of the pipe and fitting
should therefore not be exposed hardening may be slowed down manufacturers. When using
to spilled adhesive/cleaner or to considerably. Special installation Tangit PVC-C in sanitation, the
the tissue paper used for techniques are therefore required special installation instructions
cleaning. Tightly close containers at temperatures below +5ºC. For must be observed.
no longer in use in order to avoid this purpose, pipe ends and
solvent evaporation and sockets to be bonded are warmed
thickening. Remove the skin of to +25 to +30ºC by means of a
dried-up adhesive. Strip off suitable hot-air blower (explosion-
thickened adhesive adherent to proof) and then bonding is done
the brush with dry tissue paper. as described above. The finished
Cleaned brushes must be dry joint must be kept at +25 to +30ºC
prior to further use. for approx. 10 minutes.

Safety measures: In case of contact with the eyes, Shelf life:


Tangit PVC-C and Tangit Cleaner rinse thoroughly with water and If stored at +20°C, shelf life is at
are flammable. Solvent vapours obtain medical advice. least 24 months from the date of
are heavier than air and may form Immediately take off any clothing filling. Date of manufacture and
explosive mixtures. Therefore stained with adhesive. batch number are indicated at the
ensure sufficient airing and bottom of the tin.
ventilation during application and For further information refer to the
drying. No smoking and no leaflets and accident prevention Disposal:
welding in the working area and in regulations of the employers' Product remains must be
the rooms adjacent to it! No open liability insurance associations disposed of as special waste.
light or fire, avoid any sparking! and the safety data sheets. Only recycle well-emptied
Accumulated solvent vapours and Detailed information on safety containers with dried-up adhesive
explosive mixtures must be requirements and work-place residues and free of solvent
removed prior to welding. hygiene in connection with Tangit vapours.
Fill the pipes with water, flush and can be found in the leaflet
purge them well. Do not close / "Working with Tangit". The respective codes of the
seal the pipes while drying. European Waste Catalogue
Prolonged inhalation of solvent Storage: (EWC) can be enquired from the
vapours may be injurious to For practical reasons, Tangit manufacturer.
health. In order to minimize should not be stored at tempera-
exposure to solvent vapours, tures below +5ºC since this leads
keep used tissue paper in closed to a higher viscosity and Internet:
containers (e.g. buckets with lids). thickening of the adhesive, thus www.tangit.com
As precaution, protective gloves affecting its workability. After
should be worn to avoid skin conditioning at room temperature
contact and maximum cleanliness and thorough stirring, the This Technical Data Sheet is
should be observed (repeatedly temperature-induced viscosity based on our present knowledge
wash hands during work and use increase and thickening is and experience.
a greasy skin cream or emulsion). reduced again.

Please note:
Version 08/2008

The above information can only be of a general nature. As materials and conditions may vary with each intended
application and thus are beyond our influence, we recommend that the user always carries out sufficient tests to
ensure our products are suitable. No liability can be accepted for particular application results based on the
information and instructions given in this leaflet.

Henkel AG & Co. KGaA – 40191 Düsseldorf, Germany