Professional Documents
Culture Documents
RO CIP tank
Dia 4 m
Height 4 m
Pipe size considered 160 mm OD
Pipe outside diameter 160 mm
Thickness of pipe 7.7 mm
Inside dia of pipe 144.6 mm
Free board considered 300 mm
Effective height 3700 mm
Effective volume 46.495571 m3
Velocity considered in pipe 2.4 m/sec
Flow into tank 141.88622 m3/hr
Time to fill up tank 0.3276962 hr
Flow
Sr. No. Description Pipe MOC
(m3/hr)
1 Main header (DMF to UF SCF) 2961 GRP
2 Branch pipes to UF SCF 740.25 GRP
3 Drain line from UF SCF to UF Waste water sump - GRP
4 Branch pipes from UF SCF outlet header to UF systems 493.5 GRP
5 UF permeate main header 468.8333 GRP
6 UF backwash pump discharge 862 GRP
7 UF CIP pump discharge 170 SS316L
8 UF blower 1344 GS
9 UF backwash pump suction 862 GRP
10 DMF backwash pump suction 538 GRP
11 DMF backwash pump discharge 538 GRP
12 RO feed pump suction header 2922 GRP
13 RO feed pump suction branch 1461 GRP
14 RO feed pump discharge branch 1461 GRP
15 RO feed pump discharge header 2922 GRP
16 NaOCl dosing pump discharge header - UF CEB 1.328 CPVC
17 NaOH dosing pump discharge header - UF CEB 0.915 CPVC
18 HCl dosing pump discharge header - UF CEB 0.767 CPVC
19 Inlet to SWRO cartridge filters - header 3032.8 GRP
20 Branch to RO CF 758.2 GRP
21 AS dosing pump discharge header - SWRO 0.2 CPVC
22 SBS dosing pump discharge header - SWRO 0.1 CPVC
23 HCl dosing pump discharge header - SWRO 0.15 CPVC
24 NaOH dosing pump discharge header - SWRO 0.6 CPVC
25 RO flushing pump discharge - SWRO 462 SS316L
26 SWRO HP pump suction branch 280 GRP
27 SWRO booster pump suction header 1840 SS-Duplex
28 SWRO HP pump discharge branch 280 SS-Duplex
29 SWRO booster pump discharge branch 460 SS-Duplex
30 SWRO inlet header 740 SS-Duplex
31 SWRO CIP pump discharge header 693 SS316L
32 SWRO reject 458.8 SS-Duplex
33 SWRO Permeate 281.2 SS316L
34 SWRO reject header 1835.2 SS-Duplex
35 UF CIP pump suction 170 SS316L
36 RO CIP tank inlet 5.020436 CPVC
37 SWRO permeate to RO CIP 141.8862 CPVC
38 SWRO CIP pump suction 693 SS316L
39 SWRO permeate water storage tank inlet header 1124.8 SS316L
40 BWRO feed pump suction header 1110 SS316L
41 BWRO feed pump suction branch 555 SS316L
42 BWRO feed pump discharge branch 555 SS316L
43 BWRO feed pump discharge header 1110 SS316L
44 SWRO reject water pump discharge 1812 GRP
45 HCL dosing pump discharge - BWRO 0.1 CPVC
46 AS dosing pump discharge - BWRO 0.1 CPVC
47 NaOH dosing pump discharge - BWRO 0.05 CPVC
48 BWRO cartridge filter inlet branch 277.5 SS316L
49 BWRO HP pump suction branch 277 SS316L
50 BWRO HP pump discharge branch 277 SS-Duplex
51 BWRO reject 27.7 SS-Duplex
52 BWRO reject header 110.8 GRP
53 BWRO permeate 249.3 SS316L
54 BWRO permeate - header 997.2 SS316L
55 RO flushing pump suction - BWRO 462 SS316L
56 BWRO permeate transfer pump suction - header 2000 SS316L
57 BWRO permeate transfer pump suction - branch 1000 SS316L
58 BWRO permeate transfer pump discharge - branch 1000 SS316L
59 BWRO permeate transfer pump discharge - header 2000 SS316L
60 Neutralisation pump discharge 100 GRP
61 Acid unloading pump 10 CPVC
62 Acid unloading pump - bypass 10 CPVC
Pipe class Pipe size Pipe OD (mm) Pipe thickness (mm) Pipe ID (mm) Velocity (m/sec)
RO CIP tank
Dia 4 m
Height 4 m
Pipe size considered 160 mm OD
Pipe outside diameter 160 mm
Thickness of pipe 7.7 mm
Inside dia of pipe 144.6 mm
Free board considered 300 mm
Effective height 3700 mm
Effective volume 46.495571 m3
Velocity considered in pipe 2.4 m/sec
Flow into tank 141.88622 m3/hr
Time to fill up tank 0.3276962 hr