DWI 07-21
4.2.1-4.2.2 Details more specifics on ID and
calibration.
The org shall assess and record validity of 4.2.3 Covers out of spec gages and what to do.
previous measuring results when equipment is 4.2.5 Covers calibration frequencies.
found not to conform.
Inspectors assign ID# and enter info in the gage Inspector assigns ID#’s and enters them into O
calibration database for pressure transducers. GageTrak, update procedure to state Gagetrak and ref
DWI 07-21.
VMC warns at the start of each test when sensors are Good
due for calibration.
3 4.1.5 Standard Torque Tools - ME shall determine ME should only need to determine torque specs from O
the required torque spec from print “and from the drawing, update procedure. Also, start this section
accepted industry torque specs”? at 4.2 for the torque tools.
ME enters tools into Torque Tooling database Change procedure to “Inspector enters into GageTrak” O
and sets up the schedule. and reference DWI 07-21 Insp Lab Operations.
Tools examined:
B538474MF 12/28/02 – okay
101072 5/11/03 – okay
100.27 5/7/02 – okay, typo on sticker changed
to 5/7/03.
22035 5/11/03 – okay
100801 6/13/03 – okay
DC101211 6/17/03 – 3 torque settings, find out how O
to enter 3 setting values in GageTrak.
Form 01-03A - Audit Checklist
Page 2 of 4
INTERNAL AUDIT CHECKLIST
ISO 7.6 (a) ...equip shall be calibrated against measurement Tightening Spec Chart on wall showing specs for N
standards traceable to measurement standards. setting different torque wrench sizes. Uncontrolled
document. Needs a form # and traceability to an
engineering standard.
4 4.1.7 Calibration of standard torque tools. Update procedure to reference DWI 07-17 Setting O
Click Wrenches.
5 4.2 DC Electric Torque Tools – Design indentifies Change procedure to reference DWI 07-21 (4.3.2) O
critical joints. Quality Mgr ensures qualified Quality Engineer responsible for coordinating outside
outside calibration org certifies DC Torque calibration services. DWI is correct.
equipment.
4.3.1 Employees not allowed to use IMTE that is past None found. Good
due.
7 4.3.2 Noncompliance plan – out of calib equipment. Ref DWI 07-21 (4.2.3) in procedure.
DWI 07-21 Out of calibration equipment is analyzed and product
(4.3.4) risk assessment is performed and documented on
Form 07-14.
Recovery plans are documented using the CAR O
process QOP-01-05. Add this part from the procedure
(4.3.4) to DWI 07-21 (4.2.3).
8 4.3.3 See DWI 07-21 4.2.4 Update procedure to reference DWI 07-21 4.2.4. O
Non-repairable gages are tagged Out of Service (form
6733) and disposed of. GageTrak is updated.
Check
10 How do you know the calibration process is 1) No tools will become past due. Excellent
working effectively?
2) No nonconformances due to a root cause of
equipment not calibrated properly will show up at final
inspection or in the field.
Act