You are on page 1of 5

CLO/GSA MARKS

DEE10013 - MEASUREMENT
CLO 1 /20
QUIZ 1 (SET2)
NAME : : VAISNAVEE A/P ANNBALAGAN
MATRIX NO. . : 16DEE19F2026
CLASS: : DEE1A TOTAL /20

ANSWER ALL QUESTIONS

SECTION A: OBJECTIVE

1. A multimeter with ___________ will provide more accurate readings. CLO1,C1

A. low impedance
B. high impedance
C. low current
D. high current

2. Choose the statement for a DC voltmeter. (CLO1, C2)

A. A small value multiplier resistor is connected in parallel to a PMMC meter


movement.
B. A large value multiplier resistor is connected in parallel to a PMMC meter
movement.
C. A small value multiplier resistor is connected in series with PMMC meter
movement.
D. A large value multiplier resistor is connected in series with a PMMC meter
movemeter.

3. The function of the multiplier resistance in a voltmeter is to (CLO1, C2)

A. Bypass the current


B. Increase the resistance of the voltmeter
C. Increase the sensitivity of the voltmeter
D. Limit the current flow through the meter movemeter
4. Figure 1 shows the scale panel of an analogue multimeter. When the range selector is set
a DC 5 V, determine the value pointed. (CLO1, C2)
Figure 1

A. 1.65 V dc
B. 6.6 V dc
C. 3.3 V dc
D. 165 V dc

SECTION B: STRUCTURE

1. Referring to figure 1, name the element of measurement in P, Q and R in measurement


system. CLO1,C1

P Q

(3 Marks)

P=Data Presentation
Q=Data Conditioning
R=Primary Sensing

2. List THREE (3) types of errors.


i.Gross Error
ii. Relative Error
iii.Random Error

CLO1, C1
(3 Marks)

3. Referring to figure 2, calculate the value of Rx. CLO1,C3


(3 Marks)
Rx

Im=
5V Rm=1kΩ

Figure 2

RS=V/Im-Rm

RS=5/150mA-1K

RS=32KΩ

4. Reffering to figure 3, calculate the value of Rx when the current is 1/4FSD and ½ FSD

CLO1,C3
R
I=20µA
(7 Marks)

Rm=250Ω

At ¼ FSD

Im= ¼ (20)= 5micro

Rs= Im - Rm/ I- Im

Rs= 5micro (250 ohm)/ (20- 5) mA

Rs= 83.3 ohm

At ½ FSD

Im= ½ (2v)= 10 micro

Rs= Im - Rm/ I- Im

Rs= 10micro (250 ohm)/ (20- 10) mA

Rs= 250 ohm