You are on page 1of 8

Ultrasonic Distance Measurer

KIT

EXPERIMENTAL MANUAL
V19.0

2
V19.0

…. A MESSAGE FROM

OUR MOTTO;

- Light years ahead – refers to leadership.

As leaders in our industry in India, we are totally committed to servicing as


the standard against which all are measured in the areas of

 Design  Quality  Value  Delivery  Support.


We are truly light years ahead of our competition in this area. That means
that you our valued customers are guaranteed satisfaction.

As you will move through this manual you will quickly discover that we have
complete, truly innovative & superior training products. We are so committed
to quality that we back our products with a complete comprehensive
warranty.

AKADEMIKA LAB SOLUTIONS


Sr. No. 15/8/1, Unit No.9, Kruti Industrial Estate,
Opp. Karishma Society, Off karve road, Kothrud,

Pune- 411038, INDIA


Contact No.:+91-9004904462
+91-7447438443
Email:info@akademika.in
www.akademika.in

3
V19.0

SAFETY RULES

Carefully follow the instructions contained in this manual as they provide you with
important points on safety during the installation, use and maintenance. Keep this
manual always with you for easy reference.

Arrange all accessories in order after unpacking, so that their integrity is checked
with respect to the packing list. Also ensure that no visible damage as such appear
on any accessories.

Before connecting the power supply to the kit, be sure that the Connecting cables
are connected correctly as per experiment.

This system must be employed only for the use, for which it has been conceived, i.e.
as educational system and must be used under the direct survey of expert
personnel. Any other use is improper and so dangerous. The manufacturer cannot
be considered responsible for eventual damages due to improper, wrong or
unreasonable uses.

In case of any fault or malfunctioning in the trainer system, turn off the power supply
and do not tamper the system. In case servicing is required, contact the service
center for technical assistance.

The kits are liable to malfunction/under-perform if they are not operated under
standard environmental conditions of temperature and humidity.

4
V19.0

WARRANTY

This system is warranted against defects in workmanship and materials. Any


failure due to defect in either workmanship or material should occur under
normal use within a year from the original date of purchase, such failure will
be corrected free of charge to the purchaser by repair or replacement of
defective part or parts. When the failure is result of user’s neglect, natural
disaster or accident, we charge for repairs regardless of the warranty period.
The warranty does not cover perishable items like connecting chords,
Crystals, etc. and other imported items.

This warranty is subject to the following conditions and limitations.


The warranty is void and inapplicable if the defective product is not brought
or sent to our authorized service center or sales outlet within the warranty
period. Defective product is, on Akademika Lab Solutions sole judgment.
The defective product will be replaced with new one or repaired without
charge or with charge.

In the warranty period if the service is needed, purchaser should get in


touch with the service center or sales outlet. The purchaser should return
the product to the service center or sales outlet at his or her sole expense.
The loss and damage in transit will be outside the preview of this warranty. A
returned product must be accompanied by a written description of the
defects. Type and Model No. of kit has to be mentioned specifically. We
return the product to the purchaser at our expense. In case that warranty
does not cover the product on Akademika Lab Solutions judgment, we repair
the product after obtaining prior permission from purchaser who receives an
estimate statement about repairing charges. In such case, Akademika Lab
Solutions bares the transporting expenses required to send back all the
repaired products for the moment, and then repairs and transporting
expenses will be charged against the purchaser by the statement of
accounts.

When the authorized sales agents sell our products, they must notify the
purchaser of the warranty contents, but have no rights to stretch the
meaning of original warranty contents or offer additional warranty.
Akademika Lab Solutions does not provide any other promise or suggestive
warranty and hold no liability for the damage caused by negligence,
abnormal use or natural disaster. Akademika Lab Solutions is not
responsible for the damages even if it is notified of above dangers in
advance as well.

For more special service or overall repairs, maintenance and upgradation of


products, be sure to contact our service center or sales outlet.

5
V19.0

Ultrasonic Distance Measurer


OWNER’S MANUAL

PREPARATION INSTALLING BATTERIES

Your measurer requires 9V battery (not supply) for power. For the best performance
and life, we recommend alkaline battery. Follow these steps to install a battery.

1. Slide the battery compartment cover in the direction of the arrow to remove it.
2. Snap the battery in the compartment. As indicated by the polarity symbols (+ and -
) marked inside.
3. Replace the cover.
4. When Low Battery Icon appears or the measurer stops operating properly, replace
the battery.

Caution: If you do not plan to use the measurer for a month or more, remove the
battery, Batteries can leak chemicals that can destroy electronic parts.

STABILIZING THE MEASURER

Your measurer is sensitive to changes in temperature and humidity. Before you use
the measurer, wait about 15~30 minutes for it to stabilize to the current room’s
temperature.

OPERATION

 TURNING THE MEASURER ON/OFF

To turn on the measurer, press MEASURER. The measurer turns itself off if no key
is pressed within about 30 seconds.

 TAKING A MEASUREMENT

1. Press MEASURE to turn on the unit. The measurer beeps then the distance
between the measurer and the point you measured appears.
2. Hold the bottom of measure flat against a wall, about halfway between the floor
and ceiling. Be sure there is a clear path to the point you want to measure and that
your head or hands do not block the front of the measurer.
3. Repeatedly press FEET/METER until FEET appears (to measure in feet) or until
METER appears (to measure in meter)

 Notes:

The measurement appears for about 30 seconds (or longer if you press another key)
ERROR might appear if you try to measure a distance shorter than the range of 2
feet (0.50m) or longer than 60 feet (18.288meters)

6
V19.0

 Measuring Tips

Some type of curtains and blinds can absorb sound waves. Causing measurements
to be inaccurate. If you are measuring distances in a room with curtains. open the
curtains before measuring the distance to a window behind them. Also, be sure that
the window is closed. If there is not clear path between the points where you are
measuring. You might receive a false reading from sound waves bouncing off
objects such as chairs, tables and objects with uneven surfaces. If you are not sure if
a measurement is correct, move slightly to one side then measure the distance
again. If the surface of a wall you are measuring is not sold and flat, or if you are
measuring in a narrow corridor. You might receive a false reading .if this happens,
use a sold surface to measure or move to the centre of the corridor. To measure a
distance longer than 60 feet (18.288 meters) Select a point in the middle of the room
(for example) measure from the centre of the room toward each side. Then add the
two measurements.

 SAVING A MEASUREMENT

1. Follow the steps under “Taking a Measurement” to measure a dimension.


2. Press STORE then a memory key (M1, M2, M3).M and the number of the memory
location you choose (1,2 or 3)appear and the measurer stores the reading in that
memory location.
3. If necessary, repeat steps 1 and 2 to save up to three measurements.
4. To display a measurement stored in a memory location , press that memory key
(M1,M2,M3). The measurement stored in that memory location appears.
5. To delete a measurement stored in a memory location, simply store a new one in
its place.
6. To clear all stored measurements, hold down ALL MEMORY CLEAR for about 3
seconds, the measurer beeps and M and the number of the memory location you
chose (1,2 or 3) disappears.

Note: Data of AREA or VOLUME can not be saved.

 CALCULATING VOLUME

To find the volume of a room, Measure the height. Width and the length of the room
and store each measurement in a different memory location (see “Saving a
Measurement”). Then press VOLUME, The volume calculation result appear.

 CALCULATION AREA

Follow these steps to find the area of any two stored measurements
1. Measure the width and length of a room and store the measurements in M1 and
M2 (see “ Saving a Measurement”). Press AREA, M1 and M2, the area calculation
appear.

7
V19.0

 ADDING/SUBSTRACTING STORED

 MEASUREMENTS

1. Measure any two dimension of a room and store the measurements in memory
locations 1 and 2(see ”Saving a Measurement”)
2. Press ALL MEMORY CLEAR.
3. Press M1, +, M2, then + to add the measurements, or M1, -, M2, then – to
subtract them. The value of the calculation appears.
4. To clear the display and do another measurement, press ALL MEMORY CLEAR.
USING LASER To have a laser pointer, press LASER. The laser pointer disappears
automatically after about five seconds

 SPECIFICATIONS

1. Power 1x9V
2. Unit of measurement Feet or Meters
3. Accuracy 0.5%+1 digit (2~60ft)
4. Working Frequency 40kHz
5. Working Temperature 32℉to 109.4℉(0℃ to 43℃)
6. Range 2 to 60 ft (0.50 to 18.288m)
7. Specifications are typical; individual units might vary.
8. Specifications are subject to change and improvement without notice.

Caution:
The laser emitted from the unit is visible laser of 650nm wavelength
Don’t stare into the laser beam and also don’t shoot laser beam to any other’s eyes.
Class II laser product Output < 1 mw
Notes:
The product has passed EN60825-1
Corresponding label is affixed on the back of the unit.