Professional Documents
Culture Documents
97
Brueninghaus Hydromatik 1
RE 91710/03.97
Ordering code
A10V EC 45 / 52 W - R F
Fluid
Mineral oil (no code)
Size
Displacement Vg max (cm 3) 45
Control devices
Hydraulical two-point control HZ HZ
Direct control pressure DG DG
without pilot valve
Series
52
Direction of rotation
Viewed on shaft end bi-directional W
Minimum displacement
stepless adjustable Vgmin = 12 cm3 to Vgmax
Example 12 cm3 - please state when ordering 12
Seals
NBR (Nitrile caoutchouk DIN ISO 1629) with shaft sealring FPM P
FPM (Fluor caoutchouk DIN ISO 1629) V
Shaft end
SAE-splined R
Mounting flange
Special 2-bolt mounting flange F
= in preparation
= Available
2 Brueninghaus Hydromatik
RE 91710/03.97
Technical data
Fluid
For extensive information on the selection of fluids and for Notes on the selection of the hydraulic fluid
application conditions, please consult our data sheets RE 90220 In order to select the correct fluid, it is necessary to know the tank
(mineral oils) or RE 90221(environmentaly accetable hydraulic temperature (open circuit) in relation to the ambient temperature.
fluids). The hydraulic fluid should be selected so that within the opera-
You might have to consider reduced operating data with ting temperature range, the operating viscosity lies within the
environmentaly accetable hydraulic fluids. Please contact our optimum range (νopt ) (see shaded section of the selection dia-
technical department. gram). We recommend that the highest possible viscosity range
should be chosen in each case.
Operating viscosity range Example: At an ambient temperature of X°C, the operating
In order to obtain optimum efficiency and service life, we temperature is 60°C. Within the operating viscosity range (νopt;
recommend that the operating viscosity (at operating tempera- shaded area), this corresponds to viscosity ranges VG 46 or VG
ture ) be selected from within the range: 68. VG 68 should be selected.
Important: The leakage oil (case drain oil) temperature is
νopt. = Operating Viscosity 16...36 mm2/s influenced by pressure and pump speed and is always higher
referred to the tank temperature (open circuit). than the tank temperature. However, at no point in the system
may the temperature exceed 90°C.
Viscosity limits If it is not possible to comply with the above conditions because
The limiting values for viscosity are as follows: of extreme operating parameters or high ambient temperatures,
ν min = 10 mm2/s please consult us.
short term at a maximum permissible drain
temperature of 90° C.
ν max = 1000 mm2/s Filtration of fluid
short term on cold start In order to ensure correct functioning of the unit, a minimum level
of cleanliness to NAS 1638 class 9,
Temperature range (see selection diagram) to SAE; ASTM, AIA class 6 or
t min = -25° C to ISO/DIS 4406 class 18/15 is required.
t max = 90° C If it is not possible to comply with the above conditions, please
consult us.
Selection diagram
- 20° 0° 20° 40° 60° 80° 100°
1000 1000
600
400
VG
VG
VG
200
VG
VG 8
22
32
46
6
10
0
100
80
60
/ s)
ν (mm22/s)
40
36
υ opt
Viscosity υ
Viskosität
20
15 16
10 10
- 25° - 10° 10° 30° 50° 70° 90° Temperature
Temperatur
t (° C)
Fluid temperature range
t min = - 25° C Druckflüssigkeitstemperaturbereich t max = + 90° C
Brueninghaus Hydromatik 3
RE 91710/03.97
Technical Data
Operating pressure range Mounting position
Pressure at ports A or B Is optional. The motorhousing must be filled with oil during
Nominal pressure pN 280 bar commissioning operation. Install drain line in such a manner that
Peak pressure p max 350 bar housing cannot empty during stand still, i.e. make sure drain line
(Pressure data to DIN 24312) ends below min. fluid level. The port, located at the highest point
should be used for filling the housing and for connecting the drain
Caise drain pressure line.
Max. permissible pressure at ports L,L1
p abs max 2 bar
Displacement
The minimum displacement is factory set in accordance with the
ordering code.
4600
4400
Speed nmax [min-1] →
4200
4000 Direction of force
3800
3600
3400
3200
3000
0 10 20 30 40 45
Displacement Vg [cm3 ] →
Sizing calculation
Vg • n
Inlet flow qV = [L/min] Vg = displacement [cm3] per revolution
1000 • ηv ∆p = pressure differential [bar]
1,59 • Vg • ∆ p • ηmh n = speed [min-1]
Output torque T= [Nm]
100 ηv = volumetric efficiency
ηmh = mechanical-hydraulical efficiency
T•n q • ∆ p • ηt ηt = overall efficiency (ηt = η • ηmh)
Output power P= = V [kW]
9549 600
4 Brueninghaus Hydromatik
RE 91710/03.97
280 max
Pilot pressure X1 (bar) →
30
10
0
Vg min Vg max
Displacement
Technical data HZ
minimum pilot pressure 30 bar
maximum perm. pilot pressure 280 bar
Brueninghaus Hydromatik 5
RE 91710/03.97
100
60
20
6 Brueninghaus Hydromatik
RE 91710/03.97
Bri
Brueninghaus Hydromatik 7
RE 91710/03.97
Before finalising your design, please request ertified drawing.
Dual displacement motor A10VEC, Series 52 Subject to revision.
Unit dimensions
A10VEC 45 HZ /52 W XX-PRF 21 X
with port plate 21
3.4 8.2
3.6
1.9
Section (Bri)
20°
163
ø4
Detail Y
66 10 Br 66
89 26 M10 110 51 Bri
1/4-20UNC-2B
Y X L
18
104
19°
74
87
56.5
57
48
10°
L
ø135h8
ø71.7
L R
ø110
ø1"
ø14
48
96
16
40°14.4 26 L1
66 50
MB MA
160
198
177
96 X A
ø19
R3
95
1.5
ø134.6
72
50.8
useable
spline length 27,5 B
23.8
129 14
98
Connections
A,B Pressure port SAE 3/4", (high pressure range)
L, L1 Case drain port M18 x 1,5
MA, MB Measuring port M18 x 1,5 (plugged)
Bri Brake release connection (internal) ø4
Br Brake release port (external) M12 x 1,5 (plugged)
X Pilot pressure port M14 x 1,5
8 Brueninghaus Hydromatik
RE 91710/03.97
Before finalising your design, please request ertified drawing.
Dual displacement motor A10VEC, Series 52 Subject to revision.
Unit dimensions
A10VEC 45 HZ /52 W XX-PRF 81 X
with port plate 81
3.4 8.2
3.6
Section (Bri)
1.9
20°
ø4
7/8-14UNF-2B
Detail Y 163 Br 66
Bri
66 10 110 51
89 26 17
1/4-20UNC-2B
Y X L
104
89
19°
56.5
74
57
48
ø135h8
10°
L
ø71.7
L R
ø110
ø1"
48
ø14
96
16
40°14.4 L1
26 66
MB MA 160
198
177
X
93.8
10
A
93
R3
1.5
ø134.6
72
useable
spline length 27,5
129 14
98
Connections
A,B Pressure port 1 1/16-12 UN-2B
L, L1 Case drain port 7/8-14 UNF-2B
MA, MB Measuring port M18 x 1,5 (plugged)
Bri Brake release connection (internal) ø4
Br Brake release port (external) M12 x 1,5 (plugged)
X Pilot pressure port 9/16-18 UNF-2B
Brueninghaus Hydromatik 9
RE 91710/03.97
Before finalising your design, please request ertified drawing.
Dual displacement motor A10VEC, Series 52 Subject to revision.
Unit dimensions
A10VEC 45 DG /52 W XX-PRF 21 X
with port plate 21
3.4 8.2
3.6
1.9
Section (Bri)
20°
163
ø4
Detail Y 66
66 10
Br 97 51
89 26 M10 Bri
G
1/4-20UNC-2B
Y L
17
104
19°
87
56.5
74
57
48
10°
ø135h8
L
ø71.7
ø110
L R
ø1"
ø14
48
96
16
40° 14.4 L1
26 66 50
MB MA 160
198
177
G A
ø19
R3
85
1.5
ø134.6
72
50.8
useable 27,5
spline length
23.8 B
129 14
98
Connections
A,B Pressure port SAE 3/4", (high pressure range)
L, L1 Case drain port M18 x 1,5
MA, MB Measuring port M18 x 1,5 (plugged)
Bri Brake release connection (internal) ø4
Br Brake release port (external) M12 x 1,5 (plugged)
G Displacement control M14 x 1,5
10 Brueninghaus Hydromatik
RE 91710/03.97
Brueninghaus Hydromatik 11
RE 91710/03.97
Size:
Variable pump 28 cm3 45 cm3 71 cm3 100 cm3 140 cm3
A10VO
Control devices:
series 31 DG Two-point control, direct control
RE 92701 DR Pressure control
DRT Pilot pressure dependent pressure regulator
DFR Pressure and flow control
DFLR Pressure/flow and power control
Variable pump DFSR Pressure/flow and summary power control
A10VSO FHD Pilot pressure dependent flow control with
pressure cut-off
series 31 FE1 Electonic flow control
RE 92711 DFE1 Electonic pressure and flow control
DS Speed control, secondary control (RE 92715)
Size:
16 cm3
Variable pump
A10VSO Control devices:
DR Pressure control
series 31 DFR Pressure and flow control
RE 92712 DFR1 Pressure and flow control orifice in X-port plugged
DFE1 Electonic pressure and flow control
Size:
10 cm3
Variable pump
A10VSO Control devices:
series 52 DR Pressure control
DRG Pressure control, remote control
RE 92713 DFR1 Pressure and flow control orifice in X-port plugged
Brueninghaus Hydromatik GmbH, Plant Horb, An den Kelterwiesen 14, D–72160 Horb 1, ☎ (07451) 920, Telex 765 321, Telefax (07451) 8221
The specified data is for product description purposes only and may not be deemed to be
12 Brueninghaus Hydromatik guaranteed unless expressly confirmed in the contract. All rights reserved — Subject to revision