Professional Documents
Culture Documents
Company
City g
Country
PROPIETARIO
RECTIFICAR CO
GRUPO REGISTROS
FACTOR
11
MOJU MONTEIRO CO
ITAJAI SANTABrazil View
G0
G1
G2
G3
G4
G5
G6
G7
G8
G9
V0
V1
V2
V3
V4
V5
V6
V7
V8
V9
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
S0
S1
S2
S3
S4
S5
S6
S7
S8
S9
R0
R1
R2
R3
R4
R5
R6
R7
R8
R9
H0
H1
H2
H3
H4
H5
H6
H7
H8
H9
U0
U1
U2
U3
U4
U5
U6
U7
U8
U9
P0
P1
P2
P3
P4
P5
P6
P7
P8
P9
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
A0
00
01
02
03
04
10
11
13,4
16
14
20
21
22
25
26
30
31
32
40
41
42
50
51
52
53
60
61
62
63
64
65
66
67
70
71
72
73
74
75
76
77
78
GP
VH
BU
BK
SN
RE
RT
RS
HR
HI
UT
PL
PF
PC
PS
TN
TD
TG
AS
aracteristicas
Contenedor para uso general sin ventilación, Abertura (s) en una o las dos extremidades.
Contenedor para uso general sin ventilación, Aberturas de aireación pasivas en la parte superior del espacio de carga.
Contenedor para uso general sin ventilación, Abertura (s) en una o en las dos extremidades más abertura (s) sobre una de las d
Contenedor para uso general sin ventilación, Abertura (s) en una o en las dos extremidades más abertura (s) parcial (es) sobre
Contenedor para uso general sin ventilación, (Libre).
Contenedor para uso general sin ventilación, (Libre).
Contenedor para uso general sin ventilación, (Libre).
Contenedor para uso general sin ventilación, (Libre).
Contenedor para uso general sin ventilación, (Libre).
Contenedor para uso general sin ventilación, (Libre).
Contenedor para uso general ventilado, Sistema de ventilación no mecánico, abertura de aireación en la parte superior e infer
Contenedor para uso general ventilado, (Libre).
Contenedor para uso general ventilado, Sistema de ventilación mecánica situado en el interior.
Contenedor para uso general ventilado, (Libre).
Contenedor para uso general ventilado, Sistema de ventilación mecánica situado en el interior.
Contenedor para uso general ventilado, (Libre).
Contenedor para uso general ventilado, (Libre).
Contenedor para uso general ventilado, (Libre).
Contenedor para uso general ventilado, (Libre).
Contenedor para uso general ventilado, (Libre).
Contenedor para productos sólidos a granel, Furgón de tipo no presurizado, Cerrado.
Contenedor para productos sólidos a granel, Furgón de tipo no presurizado, Estanco al aire.
Contenedor para productos sólidos a granel, Furgón de tipo no presurizado, (Libre).
Contenedor para productos sólidos a granel, Presurizado, Descarga horizontal, presión de ensayo 150 kPa 1
Contenedor para productos sólidos a granel, Presurizado, Descarga horizontal, presión de ensayo 265 kPa
Contenedor para productos sólidos a granel, Presurizado, Descarga por inclinación, presión de ensayo 150 kPa
Contenedor para productos sólidos a granel, Presurizado, Descarga por inclinación, presión de ensayo 265 kPa
Contenedor para productos sólidos a granel, Presurizado, (Libre).
Contenedor para productos sólidos a granel, Presurizado, (Libre).
Contenedor para productos sólidos a granel, Presurizado, (Libre).
Contenedor especializado para transporte de ganado.
Contenedor especializado para transporte de automóviles.
Contenedor especializado para transporte de pescado vivo.
Contenedor especializado, (Libre).
Contenedor especializado, (Libre).
Contenedor especializado, (Libre).
Contenedor especializado, (Libre).
Contenedor especializado, (Libre).
Contenedor tipo plataforma con super- estructura incompleta con: Contenedor tipo plataforma con super- estructura comple
Contenedor tipo plataforma con super- estructura incompleta con: Contenedor tipo plataforma con super- estructura comple
Contenedor tipo plataforma con super- estructura incompleta con: Contenedor tipo plataforma con super- estructura comple
Contenedor tipo plataforma con super- estructura incompleta con: Contenedor tipo plataforma con super- estructura comple
Contenedor cisterna, para líquidos no peligrosos, Presión mínima 45 kPa
Contenedor cisterna, para líquidos no peligrosos, Presión mínima 150 kPa
Contenedor cisterna, para líquidos no peligrosos, Presión mínima 265 kPa
Contenedor cisterna, para líquidos peligrosos, Presión mínima 150 kPa
Contenedor cisterna, para líquidos peligrosos, Presión mínima 265 kPa
Contenedor cisterna, para líquidos peligrosos, Presión mínima 400 kPa
Contenedor cisterna, para líquidos peligrosos, Presión mínima 600 kPa
Contenedor cisterna, para gas, Presión mínima 910 kPa
Contenedor cisterna, Presión mínima 2200 kPa
Contenedor cisterna, Presión mínima (por decidir).
Contenedor aire/superficie
Cerrado carga general, Final abierto
Cerrado carga general, Final y lado abierto
Cerrado carga general, Final y parte lateral abierta
Cerrado carga general, Final y techo abierto
Cerrado carga general, Final, techo y laterales abiertos
Pequeños respiraderos pasivos superiores
Ventilación cerrada, Grandes respiradores pasivos superiores
Ventilación cerrda, Respiradores pasivos superiores e inferiores
Ventilación cerrada, Ventilación mecánica interior
Ventilación cerrada, Ventilación mecánica exterior
Aislante
Aislante
Climatizado
Con carga viva
Coches
Refrigerantes expandibles
Refrigerantes mecánicos
Refrigerados y climatizado
Refrigerantes expandidos
Refrigerantes mecánicos
Refrigerado y climatizado
Abierto por arriba final abierto
Abierto por arriba, obertura superior móvil en la última cuaderna
Abierto por arriba, lateral abierto
Abierto por arriba, obertura superior móvil en la última cuaderna
Plataforma, sin mamparos finales
Plataforma, mamparos finales completos
Plataforma, con posteres fijos
Refrigerado
Refrigerado y calefactado
6 068 2 20'
9 125 3 30'
12 192 4 40'
unassigned 5
unassigned 6
unassigned 7
unassigned 8
unassigned 9
Code
Container length
character
Container height
mm ft in
mm
2 991 10 1
6 068 20 2 2438
9 125 30 3 2591
12 192 40 4 2743
unassigned 5 2895
unassigned 6 > 2895
unassigned 7 1295
unassigned 8 < 1219
unassigned 9
7 150 A
7 315 24 B 2438
7 430 24 6 C 2591
7 450 - D 2743
7 820 - E 2895
8 100 - F > 2895
12 500 41 G 1295
13 106 43 H < 1219
13 600 - K
13 716 45 L
14 630 48 M
14 935 49 N
16 154 - P
unassigned R
M
a
T i
y n
p
e c
h
d a
e r
Type Detaile
s a
Code group d type Detailed type codeb
i c
code codea
g t
n e
a r
t i
i s
o t
n i
c
s
General Opening(s) at
G purpose GP one end or both G0 GA
container ends
Passive vents
Without
G at upper part of G1 GB
ventilation
cargo space
Opening(s) at
one or both
G ends plus “full” G2 GD
opening(s) on
one or both
sides
Opening(s) at
one or both
ends plus
G “partial” G3 GG
opening(s) on
one or both
sides
G (unassigned) G4 GJ
G (unassigned) G5 GM
G (unassigned) G6 GV
G (unassigned) G7 GW
G (unassigned) G8 GX
With bulk
G G9 GY
capabilities
Non mechanical
General system,
purpose
V VH vents at lower V0 VA
container with
ventilation and upper parts
of cargo space
V (unassigned) V1 VB
Mechanical
ventilation
V V2 VD
system, located
internally
V (unassigned) V3 VG
Mechanical
ventilation
V V4
system, located
externally
V (unassigned) V5 VM
V (unassigned) V6 VV
V (unassigned) V7 VW
V (unassigned) V8 VX
V (unassigned) V9 VY
M
a
T i
y n
p
e c
h
d a
e r
Type Detaile Detaile
s a
Code group d type d type
i c
code codea codeb
g t
n e
a r
t i
i s
o t
n i
c
s
Non-
B
B pressurized, BU Closed B0
A
box type
B
B Airtight B1
B
B
B (unassigned) B2
D
Rear
B
B discharge/cat B3
G
flap type
Rear
B
B discharge/full B4
J
width opening
Rear
B
B discharge/full B5
M
width fixed
B
B (unassigned) B6
V
B
B (unassigned) B7
W
Front
B
B discharge/full B8
X
width
B
B Side discharge B9
Y
Livestock S
S Named cargo SN S0
carrier A
Automotive S
S S1
carrier B
S
S Live fish carrier S2
D
S
S (unassigned) S3
G
S
S Generator S4
J
S
S (unassigned) S5
M
S
S (unassigned) S6
V
S
S (unassigned) S7
W
S
S (unassigned) S8
X
S
S (unassigned) S9
Y
Thermal
R
container
Mechanically R
R Refrigerated RE RO
refrigerated A
Mechanically
Refrigerated R
R RT refrigerated and R1
and heated B
heated
Mechanically R
R Self-powered RS R2
refrigerated D
Mechanically
R
R refrigerated and R3
G
heated
R
R (unassigned) R4
J
R
R (unassigned) R5
M
R
R (unassigned) R6
V
R
R (unassigned) R7
W
R
R (unassigned) R8
X
R
R (unassigned) R9
Y
Thermal
H
container
Refrigerated
and/or heated
with removable
Refrigerated
equipment
and/or heated H
H HR located H0
with removable A
externally, heat
equipment
transfer
coefficient K =
0,4 W/(m2-K)
Refrigerated
and/or heated
with removable H
H equipment H1
B
located
internally
Refrigerated
and/or heated
with removable
equipment
H
H located H2
D
externally, heat
transfer
coefficient K =
0,7 W/(m2-K)
H
H (unassigned) H3
G
H
H (unassigned) H4
J
Insulated; heat
transfer H
H Insulated HI H5
coefficient K = M
0,4 W/(m2-K)
Insulated; heat
transfer H
H H6
coefficient K = 0 V
W/(m2-K)
H
H (unassigned) H7
W
H
H (unassigned) H8
X
H
H (unassigned) H9
Y
Opening(s) at
Open-top U
U UT one or both U0
container A
ends
Opening(s) at
one or both
ends, plus U
U U1
removable top B
member(s) in
end frames
Opening(s) at
one or both
ends, plus U
U opening(s) U2
D
on one or both
sides
Opening(s) at
one or both
ends, plus
opening(s) on
U
U one or both U3
G
sides plus
removable top
member(s) in
end frames
Opening(s) at
one or both
ends, plus
partial opening U
U on one U4
J
side and full
opening on the
other side
U
U (unassigned) U5
M
Open topped
container with U
U U6
removable hard V
top
U
U (unassigned) U7
W
U
U (unassigned) U8
X
U
U Coil carrier U9
Y
Platform Platform P
P PL P0
(container) (container) A
Platform-based
container with
P
incomplete
superstructure:
Two complete P
P Fixed PF P1
and fixed ends B
Fixed posts,
either
P
P freestanding or P2
D
with removable
top member
Folding
Folding P
P PC complete end P3
(collapsible) G
structure
Folding posts,
either
P
P freestanding or P4
J
with removable
top member
P
Platform-based
container with Open top, open P
P PS P5
complete ends (skeletal) M
superstructure
Platform-based
Ship’s gear P
P container for PT P6
carrier V
named cargo
P
P Car carrier P7
W
Timber/pipe P
P P8
carrier X
P
P Coil carrier P9
Y
T
y
p
e
d
e
Main
Type group
s Detailed type Detailed type
Code characteristic
code i codea codeb
s
g
n
a
t
i
o
n
Pressurized
tank container
K
(liquids and
gases)
Liquid tank
dangerous
K K1 KB
goods £ 2,65
barc pressure
Liquid tank
dangerous
K goods >2,65 K2 KD
barc and £ 10
barc pressure
Liquid tank
dangerous
K K3 KG
goods > 10 barc
high pressure
Liquid tank non
regulated goods
K K4 KJ
requiring power
supply
Liquid tank for
dangerous
K goods £ 10 barc K5 KM
requiring power
supply
Liquid tank for
dangerous
goods > 10 barc
K K6 KV
pressure
requiring power
supply
K Cryogenic tank K7 KW
K Gas tank K8 KX
K (unassigned) K9 KY
Pressurized
and non-
N pressurized
tank container
(dry)
Hopper type
N NH vertical N0 NA
discharge
Hopper type
N N1 NB
rear discharge
N (unassigned) N2 ND
Non
N NN pressurized N3 NG
rear discharge
Non-
N pressurized N4 NJ
side discharge
Non-
pressurized
N N5 NM
tipping
discharge
N (unassigned) N6 NV
Pressurized
N N7 NW
rear discharge
Pressurized
N N8 NX
side discharge
Pressurized
N tipping N9 NL
discharge
Air/surface
A
container
AS A0
Code character
Container height Container width
> 2438 mm
ft in (8 ft) 2436 mm and £ 2500 > 2500 mm
mm
8 0
8 6 2 C L
9 4 D M
9 6 5 E N
>9 6 6 F P
4 3 8
<4 9
8 0
8 6 2
9 4
9 6 5
>9 6 6
4 3 8
<4 9
10 1 2 991
20 2 6 068
30 3 9 125
40 4 12 192
unassigned 5
unassigned 6
unassigned 7
unassigned 8
unassigned 9