You are on page 1of 3

14.

Development Length and Splices Length

Given

Rebar Diameter db := 25mm

Yeild strength of reinforcement fy := 390 MPa

Compressive strength of concrete f'c := 30MPa

db
Cover to Longitudinal Rebar GC Ce := 40mm + 10 mm +
2

Spacing of Rebar Sb := 40mm + db

Modification factor for type of concrete

ψt :=

ψt = 1

Reinforcement coating

TB :=

TB = 2

Type of concrete

λ := λ=1 (ACI 8.6.1)


Ktr := 0 For Simplification

 Sb 
Cb := min  Ce ,  Cb = 32.5 mm
 2 

Sc := Sb − db

db
Cc := Ce −
2

ψe := if TB = 1 ψe = 1
1.5 if Cc < 3  db  Sc < 6  db

1.2 otherwise
1 otherwise

ψs := 1 if db  22mm

0.8 if db  20mm

ψs = 1

Development length of deformed bar in tension

 fy ψt ψe ψs 
ld := max   db , 300 mm
1
 
 1.1 λ min ( f'c MPa , 8.3 MPa )  Cb + Ktr  
 min  , 2.5

  db  
 0.24 ψe fy 
ldh := max   db , 8  db , 150  mm
 min ( λ f'c MPa , 8.3 MPa ) 

Splices Length of Deformed bar in Tension

Lap Splices Type :=

lst := ld if Lap Splices Type = 1 lst = 1618.271 mm

1.3 ld otherwise
Development length in compression

 0.24 fy fy 
ldc := max   db , 0.044  db , 200 mm
 f'c MPa 
 MPa  MPa 
 

Splices Length of Deformed bar in Compression

0.071 fy db  0.13 fy  


lsc := max  , − 24  db , 300  mm
 MPa  MPa  

Development length of deformed bar in tension

ld = 1244.824 mm

ldh = 427.224  mm

Splices Length of Deformed bar in Tension

lst = 1618.271 mm

Development length and Splices Length in compression

ldc = 429  mm

lsc = 692.25 mm