Powercommand: Digital Generator Set Control
Powercommand: Digital Generator Set Control
PowerCommand
Digital Generator Set Control
Description Features
The PowerCommand™ (1300) Control is a • Digital Voltage Regulation.
microprocessor-based generator set monitoring, • Digital Engine Speed Governing (optional) to
metering, and control system. The control provides a provide isochronous frequency regulation
simple operator interface to the generator set, digital • Single or 3 Phase Voltage and Current
voltage regulation, digital engine speed governing, start Sensing. Wye and delta voltage sensing.
/ stop control and generator set protective functions. Current sensing with external 5 Amp current
The integration of all functions into a single control transformers.
system provides enhanced reliability and performance • Engine Starting includes relay drivers for start,
compared to conventional generator set control fuel shut off (FSO), and glow plug. Start
systems. disconnect is achieved by monitoring the
battery charging alternator.
The PowerCommand 1300 generator set control is • Generator Set Monitoring. Monitors status of
suitable for use on a wide range of generator sets in all critical engine and alternator conditions
non-paralleling applications. The PowerCommand functions.
Control is compatible with reconnectable alternators up • Generator Set Protection. Engine and
to 600VAC line to line, and can be configured for any alternator.
frequency, voltage, and power connection configuration
• Operator Display Panel (optional). Provides
from 120-600VAC line to line.
easy to use symbolic operator display of critical
The PowerCommand 1300 is designed for mounting on generator set parameters and operating
the generator set. history.
Power for the control is derived from the generator set • Advanced Serviceability using InPower™, a
starting batteries. The control functions over a voltage PC-based software service tool.
range from 8VDC to 16VDC. • Environmental Protection. The control
system is designed for reliable operation in
The control offers a wide range of standard control and harsh environments. The core control board is
optional display panel features so custom control an encapsulated module that is fully protected
configurations are not needed to meet application from the elements.
specifications. • Configurable Inputs and Outputs. Two
discrete inputs and two dry contact relay
outputs.
• Certifications. Suitable for use on generator
sets that are designed, manufactured, tested,
and certified to relevant UL, NFPA, ISO, IEC,
CE, and CSA standards.
© 2004 Cummins Power Generation Specifications subject to change without notice S-1460
.
• Warranty and Service. Backed by a The control displays current active faults, and a time-
comprehensive warranty and worldwide ordered history of previous faults.
distributor service network. LED Indicating Lamps - The optional display panel
includes LED indicating lamps for the following
Control System functions:
The standard control system includes a control board Not in Auto
with an external control switch and status indicator. Shutdown
The control board includes all functions necessary to Warning
locally or remotely start and stop, regulate voltage, and Remote Start
protect the generator set. Auto
Control Switch - RUN/OFF/AUTO - In the OFF mode Run
the generator set is immediately shut down (if running) Operator Adjustments - The optional display panel
and cannot be started. In the RUN mode the generator includes provisions for many set up and adjustment
set will execute its start sequence, and operate at rated functions via raise/lower switches. Functions that can
speed and voltage. In the AUTO mode, the generator be adjusted by the operator include:
set can be started with a start signal from a remote Time delay start (0-300 seconds)
device, such as an automatic transfer switch. The
fault/status lamp will flash until the generator set is at Time delay stop (0-600 seconds)
rated speed and voltage. Operation of the switch to the Alternator voltage (plus or minus 5%)
OFF position also resets faults in the control.
Status Indications - The control includes a lamp driver
for an external fault/status indication. When this
feature is used, it provides the operator with basic
status information on the generator set. Functions
displayed include:
• The lamp flashes during preheat (when used) and
while the generator set is starting.
• The lamp indicates “READY TO LOAD” by flashing
until the generator set is at rated voltage and
frequency, then turning on continuously.
• Fault conditions are displayed by flashing a two-
digit fault code number.
© 2004 Cummins Power Generation Specifications subject to change without notice S-1460
.
Low Lube Oil Pressure Warning/Shutdown - fumes. This panel uses a sealed membrane to provide
Level is preset (configurable with InPower) to long reliable service life in harsh environments.
match the capabilities of the engine used. Control The control system is specifically designed and tested
includes time delays to prevent nuisance
for resistance to RFI/EMI, and to resist effects of
shutdown signals. vibration to provide a long reliable life when mounted
High Engine Temperature Warning/Shutdown - on a generator set. The control includes transient
Level is preset (configurable with InPower) to voltage surge suppression to provide compliance to
match the capabilities of the engine used. Control referenced standards.
includes time delays to prevent nuisance
shutdown signals. Certifications
PowerCommand meets or exceeds the requirements of
Low Coolant Temperature Warning - Indicates
the following codes and standards:
that engine temperature may not be high enough
for a 10-second start or proper load acceptance. NFPA110 for Level 2.
Low and High Battery Voltage Warning - ISO 8528-4: 1993 Compliance, Controls and
Indicates battery charging system failure by Switchgear
continuously monitoring battery voltage. CE Marking: The control system is suitable for
Weak Battery Warning - The control system will use on generator sets to be CE-marked.
test the battery each time the generator set is EN 50081-1,2 Residential/Light Industrial
signaled to start, and indicate a warning if the emissions, or Industrial Emissions
battery indicates impending failure.
EN 50082-1,2 Residential/Light Industrial or
Fail to Start (Overcrank) Shutdown Industrial susceptibility
Fail to Crank Shutdown - Control has signaled ISO 7637-2, level 2; DC supply surge voltage test.
starter to crank engine but engine does not rotate.
Mil Std 202C, Method 101 and ASTM B117: Salt
Cranking Lockout - The control will not allow the Fog test
starter to attempt to engage or to crank the engine
when the engine is rotating. PowerCommand control systems and generator sets
are designed and manufactured in ISO9001 certified
Sensor Failure Indication - Logic is provided on facilities. The control is suitable for use on generator
the base control to detect analog sensor or sets that are UL 2200 listed.
interconnecting wiring failures.
Software
Alternator Protection InPower
High/Low AC Voltage Shutdown - High default
InPower (beyond x version) is a PC-based software
to 110% for 10 seconds, instantaneous 130%.
service tool that is designed to directly communicate to
Low default to 85% for 10 seconds
PowerCommand generator sets and transfer switches,
Overcurrent Warning/Shutdown - Warning to facilitate service and monitoring of these products.
default to 110% for 60 seconds. Shutdown default
PowerCommand for Windows
to 150% for 10 seconds.
PowerCommand for Windows is a software tool that is
Under/Over Frequency - Under default to -6Hz
used primarily by operators to remotely monitor and
for 10 seconds. Over default +6Hz for 10 seconds.
control generator sets, transfer switches, and other on-
Loss Of Sensing Voltage Shutdown site power system devices.
Field Overload Shutdown Control Interface
Environment Input signals to the base control include:
The control is designed for proper operation without Run/Off/Auto Switch - Required when the
recalibration in ambient temperatures from –40C to optional display panel is not used.
+70C, and for storage from –55C to +80C. Control will
Generator Set Status Lamp
operate with humidity up to 95%, non-condensing.
Remote Start Signal
The optional display panel is designed for proper
operation in ambient temperatures from –20C to +70C, Remote Emergency Stop
and for storage from –30C to +80C Configurable Inputs - Control includes (2) input
The control board is fully encapsulated to provide signals from customer discrete devices that are
superior resistance to dust and moisture. The optional configurable for warning, shutdown, or status
display panel has a single membrane surface, which is indication, as well as message displayed.
impervious to effects of dust, moisture, oil, and exhaust Output signals from the PowerCommand control
include:
© 2004 Cummins Power Generation Specifications subject to change without notice S-1460
.
Configurable relay outputs - Control includes PC Tool Interface - This communication port is to
(2) relay outputs rated at 2 amps. These outputs allow the control to communicate with a personal
can configured to activate on any control warning computer running InPower or PowerCommand for
or shutdown fault as well as ready to load, not in Windows software.
auto, common alarm, common warning, and Networking - This communications port is to
common shutdown. allow connection from the control to the optional
Ready to Load (generator set running) signal - display panel.
Operates when the generators set has reached
90% of rated speed and voltage and latches until Options and Accessories
generator set is switched to off or idle mode. (B+ Display Panel - Provides a local or remote operator
signal output) display of engine and alternator. Includes set up and
generator set history information.
Communications connections include:
Mechanical Drawings
224 (8.82) 33.5 (1.32)
141 (5.56)
PowerCommand
111 (4.38)
149 (5.88)
BASIC CONTROL BOARD
1300
Dimensions: mm (inches)
65 (2.56)
100 (3.94)
GOVERNOR POWER
STAGE
75 (2.95)
38 (1.50)
© 2004 Cummins Power Generation Specifications subject to change without notice S-1460
.
Electrical Interconnections
Fuel
Actuator
Gov Power
ALTERNATOR
DC ALTERNATOR
GLOW PLUG SOL
Stage
TEMP SENDER
OIL PRESS SW
MAG PICKUP
OPT. EXT FUEL
RELAY COIL B+
STARTER DISC
OR SENDER
P1
SHUTOFF
STATUS
OPT. EXT.
STARTER
LAMP
RUN/OFF/
AUTO SW
K4 K5 K6
CHASSIS
GND Battery
P11
P13
OPTIONAL OPERATOR PANEL
RECONNECTION
BLOCK
POWERCOMMAND 1300
CT1
CONFIGURABLE
READY TO LOAD
REMOTE E-STOP
REMOTE START
OUTPUTS
CT2
P12
OPERATOR
FAULT IN #2
FAULT IN #1
P1
PANEL
TO
CT3
DB9
10
11
12
13
14
15
TB1 16
1
2
3
4
5
6
7
8
9
TO SERVICE
TOOL
TO CUSTOMER
LOADS
© 2004 Cummins Power Generation Specifications subject to change without notice S-1460
.
Warranty
All components and subsystems are covered by an express limited one-year warranty. Other optional and extended factory
warranties and local distributor maintenance agreements are available. Contact your distributor/dealer for more information.
Certifications
ISO9001 - This product set was designed and manufactured in facilities certified to ISO9001.
PTS - The Prototype Test Support (PTS) program verifies the performance integrity of a generator set
design. Products bearing the PTS symbol have been subjected to demanding tests in accordance to
NFPA 110 to verify the design integrity and performance under both normal and abnormal operating
conditions.
UL - The control is suitable for use on generator sets that are listed to UL2200, Stationary Engine
Generator Assemblies.
CE - This product is suitable for use on generator sets that are CE marked.
Important: Backfeed to a utility system can cause electrocution and/or property damage. Do not connect generator sets to any
building electrical system except through an approved device or after building main switch is open.
© 2004 Cummins Power Generation Specifications subject to change without notice S-1460