Professional Documents
Culture Documents
The VITEK 2 ADVANCED EXPERT SYSTEM software is like having an expert advisor standing by your side. It
IMPROVED PATIENT OUTCOMES applies a colored indicator to each isolate that shows the level of confidence in the susceptibility results.
References:
1. Barenfanger J, Drake C, Kacich G. Clinical and Financial Benefits of Rapid Bacterial Identification and Antimicrobial Susceptibility Testing. J Clin Microbiol. 1999:37(5):1415-1418.
2. Galar A, Leiva J, Espinosa M, Guillén-Grima F, Hernáez S,Yuste JR. Clinical and economic evaluation of the impact of rapid microbiological diagnostic testing. J Infect. 2012;65(4):302-309.
3. Galar A,Yuste JR, Espinosa M, Guillén-Grima F, Hernáez-Crespo S, and Leiva J. Clinical and economic impact of rapid reporting of bacterial identification and antimicrobial susceptibility results of the most frequently processed specimen
types. Eur J Clin Microbiol Infect Dis. 2012;31(9):2445-2452
4. LaBombardi,VJ. Maximizing the Use of the Advanced Expert SystemTM to Improve Patient Care.White Paper. 2011.
CUSTOMIZE VITEK® 2 TO YOUR NEEDS
•M
anages and reports quality control results •P
rovides instrument monitoring and remote access to validate patient results
•C
onsolidates patient results which are accessible from any location
•R
eal-time cumulative statistical reports (e.g. antibiograms)
VITEK® 2 is designed to make your ID/AST workflow as rapid and reliable
as possible, while providing maximum flexibility and full traceability.
Results
in as little as 5 to 8 hours
VITEK 2 COMPACT
VITEK 2 Compact: Use ID VITEK 2 Compact: Cards inoculated inside VITEK 2 Compact: Scan
suspension to make instrument and manually transferred from cassette worksheet at the
AST suspension filling door to loading door for processing work station
FLEXIBILITY RELIABLE AND SAFE BROAD AND EXPANDING ID/AST TEST MENU
•T
he barcoding system improves traceability by linking patient •P
roven accuracy with faster results, contributing to improved IDENTIFICATION CARD TYPES: ANTIBIOTIC SUSCEPTIBILITY CARD TYPES**:
isolates and test cards. patient outcomes1-4 • GN (Gram negative bacilli) •G
ram negative Bacilli
162 organisms 36 antimicrobials and ESBL† test
•V
ITEK 2 allows patient demographics to be linked to •C
losed system: no aerosols, splattering or spills
•G
P (Gram positive cocci & bacilli) • Staphylococci &/or Enterococci
microbiology results. • F ull traceability with pre-applied barcodes 124 organisms 24 antimicrobials, 2 high level aminoglycoside screens and ICR†† test
•S
imultaneous multi-user access to VITEK 2 systems lets • L ightweight: reduced waste and biohazard disposal costs • ANC (anaerobes & Corynebacteria) • S
treptococci
microbiologists finalize results from individual workstations. while minimizing storage space 89 organisms 13 antimicrobials and ICR test
•C
LSI* compliant AST formulations available producing MICs • N
H (Neisseria & Haemophilus) • Streptococcus pneumoniae
32 organisms 16 antimicrobials
• YST (Yeast) • YST (Yeast) **Availability pending registrations as required by local regulatory authority
† Extended-spectrum-beta-lactamase
* CLSI - Clinical & Laboratory Standards Institute 54 organisms YST card now with Candida auris 3 antimicrobials †† Inducible clindamycin resistance
FLEXIBILITY TO MEET YOUR WORKFLOW NEEDS
VITEK® 2 COMPACT
©2018 bioMérieux, Inc. • BIOMÉRIEUX, the BIOMÉRIEUX logo, VITEK®, ADVANCED EXPERT SYSTEM, VILINK, MYLA, and DENSICHEK, are used pending and/or registered trademarks belonging to bioMérieux, or one of its subsidiaries, or one of its companies
VITEK® 2
CAPACITY OPTIONS HEAT DISSIPATED
• 60 cards per instrument • 512 BTU/Hr. (nominal)
CONNECTIONS ENVIRONMENTAL REQUIREMENTS
• 2 instruments can be connected to • O
perating ambient temperature
the same PC range of 20˚C to 30˚C
DIMENSIONS • O
perating humidity range: 20% to 80%
• 26’’ x 39’’ x 28’’ (100 x 71 x 67 cm) relative humidity, non-condensing
WEIGHT ALTITUDE
• 240 (110 kg) • up to 2,000 m
ELECTRICAL REQUIREMENTS
• 100/120 VAC (50-60 Hz)
• or 220/240 VAC (50-60 Hz)
VITEK® 2 XL
CAPACITY OPTIONS HEAT DISSIPATED
• 1 20 cards per instrument • 682 BTU/Hr. (nominal)
CONNECTIONS ENVIRONMENTAL REQUIREMENTS
• 2 instruments can be connected to • O
perating ambient temperature range
Patents: www.biomerieux-usa.com/patents • PRN 17-0328-00
bioMérieux, Inc. • 100 Rodolphe Street • Durham, NC 27712 • USA • Tel: (800) 682 2666 • Fax: (800) 968 9494
www.biomerieux-usa.com