type RRU5905 RRU5905 RRU5905

Version SRAN13.1 SRAN13.1 SRAN13.1


RRU Form Blade Blade Blade
Basic Specifications
Frequency Band (MHz) 1800 900 EGSM 900 PGSM
UL:1710 to 1785 UL:880 to 915 DL:925 UL:890 to 915 DL:935
Frequency Range (MHz)
DL:1805 to 1880 to 960 to 960
GSM, UMTS, LTE FDD, GSM, UMTS, LTE FDD,
GSM, LTE FDD, GL, LM, GU, GL, UL, GUL, LTE GU, GL, UL, GUL, LTE
Mode
GLM NB-IoT, GM, UM, LM, NB-IoT, GM, UM, LM,
GUM, GLM, ULM GUM, GLM, ULM
IBW (MHz) 45 35 25
OBW (MHz) - - -
RF Specifications
TX/RX Channel 2T2R 2T2R 2T2R
NR SUL Carrier
- - -
Configuration

GSM:8 TRXs LTE FDD:2 GSM:8 TRXs LTE FDD:2


GSM:8 TRXs LTE FDD:2 carriers. The carriers. The
carriers. The bandwidth per carrier bandwidth per carrier
bandwidth per carrier is 1.4, 3, 5, 10, 15, is 1.4, 3, 5, 10, 15,
Carrier Capacity
is 1.4, 3, 5, 10, 15, or 20 MHz. LTE NB- or 20 MHz. LTE NB-
or 20 MHz. LTE NB- IoT:1 carrier UMTS:7 IoT:1 carrier UMTS:7
IoT:1 carrier carriers without MIMO carriers without MIMO
4 carriers with MIMO 4 carriers with MIMO

Output Power 2x80 W 2x80 W 2x80 W


Typical Power
Configuration without View View View
NB-IoT
NB-IoT Typical Power
View View View
Configuration
GSM Receiver
Sensitivity
-114.0 -114.0 -114.0
with One Antenna
(dBm)
UMTS Receiver
Sensitivity
- -125.9 -125.9
with One Antenna
(dBm)
LTE FDD Receiver
Sensitivity
-106.6 -106.6 -106.6
with One Antenna
(dBm)
LTE TDD Receiver
Sensitivity
- - -
with One Antenna
(dBm)
NB-IoT Receiver
Sensitivity
-127.3 -127.3 -127.3
with One Antenna
(dBm)
Engineering Specifications
-48 V DC; voltage -48 V DC; voltage -48 V DC; voltage
Power Supply range: -36 V DC to - range: -36 V DC to - range: -36 V DC to -
57 V DC 57 V DC 57 V DC
400 mm x 300 mm x 100 400 mm x 300 mm x 100 400 mm x 300 mm x 100
Dimensions (H x W x
mm (without the mm (without the mm (without the
D)
housing) housing) housing)
15 (without the 15 (without the 15 (without the
Weight (kg)
housing) housing) housing)
Typical Power
Consumption for an 370 370 370
RRU(W)
Without solar Without solar Without solar
radiation: -40°C to radiation: -40°C to radiation: -40°C to
Operating Temperature +55°C With solar +55°C With solar +55°C With solar
radiation: -40°C to radiation: -40°C to radiation: -40°C to
+50°C +50°C +50°C
Protection Rating IP65 IP65 IP65
Relative Humidity 5% RH to 100% RH 5% RH to 100% RH 5% RH to 100% RH
Environment
1 g/m3 to 30 g/m3 1 g/m3 to 30 g/m3 1 g/m3 to 30 g/m3
Relative Humidity
Air Pressure 70 kPa to 106 kPa 70 kPa to 106 kPa 70 kPa to 106 kPa
Anti-Seismic
NEBS GR63 zone4 NEBS GR63 zone4 NEBS GR63 zone4
Performance
Surge Protection
20 kA 20 kA 20 kA
Specifications
CPRI Port Specifications
Number of CPRI Ports 2 2 2
CPRI Data Rate 1.25, 2.5, 4.9, or 1.25, 2.5, 4.9, or 1.25, 2.5, 4.9, or
(Gbit/s) 9.8 9.8 9.8
Star, chain, or dual- Star, chain, or dual- Star, chain, or dual-
Topology
star star star
GU CPRI MUX: 6 levels GU CPRI MUX: 6 levels GU CPRI MUX: 6 levels
Multimode (excluding Multimode (excluding Multimode (excluding
Cascading Levels
GU) CPRI MUX: 4 GU) CPRI MUX: 4 GU) CPRI MUX: 4
levels levels levels
GU: 40 LTE FDD or GU: 40 LTE FDD or GU: 40 LTE FDD or
multimode (including multimode (including multimode (including
LTE FDD and excluding LTE FDD and excluding LTE FDD and excluding
NB-IoT): When the NB-IoT): When the NB-IoT): When the
LBBPc or LBBPd1 is LBBPc or LBBPd1 is LBBPc or LBBPd1 is
configured: 20 When configured: 20 When configured: 20 When
the LBBPd2, UBBPd3, the LBBPd2, UBBPd3, the LBBPd2, UBBPd3,
Maximum Distance from UBBPd4, UBBPd5, UBBPd4, UBBPd5, UBBPd4, UBBPd5,
the BBU (km) UBBPd6, or UBBPe is UBBPd6, or UBBPe is UBBPd6, or UBBPe is
configured: 40 When configured: 40 When configured: 40 When
the LBBPd3 is the LBBPd3 is the LBBPd3 is
configured: Number of configured: Number of configured: Number of
cells ≤ 3: 40 Number cells ≤ 3: 40 Number cells ≤ 3: 40 Number
of cells ≥ 4: 20 of cells ≥ 4: 20 of cells ≥ 4: 20
Multimode (including Multimode (including Multimode (including
NB-IoT): 20 NB-IoT): 20 NB-IoT): 20