BFSO62A series semi-automatic stretch blow molding machine controller is focus
on MCU which with number tube, time and logic action.
BFS062A series’ features:
n WATCHDOG
n Hardware WATCHDOG
n Five number tube
n EEPROM data save, needn’t batteries
n Count function
n Alarm function
n SOFTWAREBACKUP, about the procedure of ROM, consumer can switch them through
dial number.
enactment, pressing key for saving data, then return. If you donnot press
State direction section has 28 state direction lamps. There are five groups
which are work direction lamp, alarm direction lamp, enactment timer, Parameter
direction lamp and input and output direction lamp.
1. When PWR is normal, PWR direction lamp is bright. The COUNT
direction lamp bright means that now it shows count. The TIME direction lamp
bright means that now it shows time.
2. When the alarm lamp bright, it must have some problem.
3. After entering parameter enactment state, timer lamp bright means it shows
enactment value.
4. Input direction lamp bright means it switch on corresponding input points.
5. When switch on the input point, corresponding lamp bright..
shows clamping time or product count. Press for switching. The COUNT direction lamp
bright means that now it shows count. The TIME direction lamp bright means that now it shows
time.
Specific manipulate
① Electrify:
After controller electrifying, the number tube show
②Press key
Picture 1: Explain of operating
动作 action 功能 function
Press stretch , electrify the stretch valve; Press again, break the
electric.
Press T/C, The COUNT direction lamp bright means that now it
shows count . The TIME direction lamp bright means that now it
shows time.
When you choose work both left and right, this key is no
function. When you choose work either left or right, this key is
enactment of left or right parameter.
③ enactment parameter
After setting, press to save parameter and return. (If you donnot press key, it will
save by itself after 15second and return.
When you choose work both left and right, just set DELAY PRE.BLOW BLOWING
EXHAUST. When you choose either left or right, at that time L.MOULD ON lamp bright, set four
parameters in left. When R.MOULD ON lamp is bright, set four parameters in right.
④ Automatic Operate
After setting parameter, it can operate automatic.
Alarm direction
Alarm content solution
lamp
When the clamping not reach the
Check the photoelectricity switch
ERR1 position after open for 5 seconds, the
of clamping.
lamp will bright.
When the stretch electric not reach the
Check the photoelectricity switch
ERR2 position after 5seconds, the lamp will
of stretch.
bright.
The first one OFF, it chooses work program both sides. The first one ON, it
chooses work program either left or right.
Please choose the correct program before electrify. If program is not
according with model, it will lead to error movement. This manipulate
must be done by commision person. The controller will switch under
electrify. The program will not change. It will change after electrify
again.
Third. Attention
1. Reading the specification before manipulate and abiding regulations strictly.
Technical parameter:
ITEM MG-880
Clamping Force 20T
Clamping Stroke 230mm
Max.Stretching Stroke 380mm
Number of Cavities 2Cavity
Theoretical Output 0.1-2.5L:880BPH
3-6:380BPH
Max.Mould Thickness 300mm
Space Between Tie Bars 280 X500mm
Electrical System
Voltage Standard 380v/3PH/50Hz or special order
Number of Heating Zone 2Sections
Total Power(Full Loaded) 6KW
Container
Max.Container Volume 0.1-2.5L(2 Cav)
3-6(1Cav)
Neck Diameter Range 15-60mm
Max.Container Diameter 35-220mm
Max.Container Height 450mm
Auxiliary
Low Air compressor 8-10Bar
High Air compressor 30Bar
Air Dryer 1.2/30
Dimension&Weight(L XW XH)