You are on page 1of 2

Wato

[110 A.D. - 207 A.D.]

The first Chinese surgeon who developed


the use of anesthesia and furthered
the Chinese knowledge of anatomy

Order Information

Main unit includes ventilator, ACGO, 1 backup flowmeter, breathing circuit with 1 CO2 absorber, 2 drawers, LED
light, alarm light, 1 lithium battery, switch and user manual.

WATO EX-55 WATO EX-65

Color LCD screen 8.4 inch 10.4 inch

Gas supply (electronic flowmeters) O 2, O 2+N 2O, O 2+N 2O+Air,O 2+Air O 2, O 2+N 2O, O 2+N 2O+Air,O 2+Air

Retractable work surface Optional Optional

Position for vaporizers 1 or 2 1 or 2

Isoflurane, Enflurane, Sevoflurane, Isoflurane, Enflurane, Sevoflurane,


Vaporizers(Selectatec ® compatible)
Halothane, Desflurane Halothane, Desflurane

20-1500ml, with tidal volume 20-1500ml, with tidal volume


Volume-controlled ventilation compensation compensation

Yes Yes
Electronic PEEP

Pressure-controlled ventilation Optional Yes

SIMV N/A Optional

PSV with Apnea Backup N/A Optional

Airway pressure monitoring Yes Yes

Inspired oxygen monitoring Yes Yes

Paramagnetic oxygen monitoring N/A Optional

CO 2 monitoring Optional Optional

Airway gas monitoring N/A Optional

BIS ® monitoring N/A Optional

PV loop and FV loop N/A Optional

For more information, please contact Mindray sales representatives

WATO EX-65/55
TM

Anesthesia Machines

2008

P/N:ENG-WATO55/65-420285-20081230
VCV, PCV, SIMV, PSV, Apnea Backup
WATO EX-65/55 TM
Anesthesia Machines FiO2, Paramagnetic O2, EtCO2, AG, BIS, Loops

Maximum technical performance, contemporary Besides Volume and Pressure ventilation, there are
and ergonomic design, closed with the latest SIMV, Pressure Support (PSV) and Apnea Backup mode
modern anesthesia concept applied in more complicated situations

The WATO EX-65/EX-55 is designed for ease of use , Minimum TV downs to 20ml suitable for patients of
incorporating the maximum patient safety in daily any age, by only one bellows and one circuit
anesthesia practice. A small footprint and compact size is
TV compensation and electronical PEEP automatically
appropriate for any environment where space is limited.
corrects for fresh gas flow, system leak and the
Some of the specifications are: compliance change in the circuit
Electronic flow meters for O 2, N 2O or Air with a backup The ascending bellows can provide immediate visual
tube for the emergency information on the adequacy of fresh gas flow and
give indication of the system leaky occurrence
Support up to 2 vaporizer positions
Integrated pressure, volume and oxygen monitoring
An electronically-controlled, pneumatically-driven
ventilator, either mechanical ventilation or
spontaneous breath, supports a variety of patients. What you set is what the patient will get!

Switching Auxiliary Common Gas Outlet (ACGO) allows


you to use in the 3rd party's semi-open circuits

Modular design monitoring for multi-gas, Compact device for closed and semi-closed system
paramagnetic oxygen and BIS® measurement
Easy to disassemble and assemble all the components
Compatible with Mindray patient monitors and other - convenient for clean and maintenance
medical devices

Specific design for low flow anesthesia Fully autoclavable at 134°


C and nature latex free

Heating device avoids humidity condensation in the


flow sensors that are integrated and protected in the
The highest quality and reliability of Sigma Delta®
circuit
Vaporizer:

Service free Quick release canister

Selectatec® compatible interlock safe systems


Excellent ergonomic breathing circuit!
Superb performance over a wide range of vapor
concentration and temperature, particularly at
low flow

Available for Halothane, Enflurane, Isoflurane,


Sevoflurane (Sigma Delta®) and Desflurane Monitoring modules can be used both in WATO
(Sigma Alpha®) EX-65/55 and Beneview TM monitors
Proven technology of vaporizers!

The measurement for CO 2, N2O,paramagnetic O 2


The large color LCD screen displays all ventilator's and 5 anesthetic agents (auto-identified) can be
setting data, measurement information, loops and displayed both in numeric and curves
numeric/graphic trends
BIS® measurement can reduce the recovery time
Multi-display selectable: Standard , large font or
of the patient and prevent drug over dose
monitoring

Intelligent alarm management, e.g. permanent silent A connector allows the sample gas to return to
volume/apnea alarm especially used in the procedure the scavenging system
of cardio bypass
Optional monitoring capabilities!
Friendly and intuitive user interface!

You might also like