You are on page 1of 4

Tube Aerat

o
tic

r
ta

Un
The S

it • For 30 years. Simply. Wo


rl d w
id e
.

P O L C O N
AERATION SYSTEMS INC.
HELIXOR ®
MADE IN CANADA
P O L C O N ®
HELIXOR's Key Features
AERATION SYSTEMS INC. • Efficient oxygen transfer and
designs, manufactures and markets complete mixing conditions;
POLCON ® HELIXOR ® Systems • Low capital costs due to
through an international representative simplicity of installation and
network. start-up;
Our POLCON HELIXOR Unit, • No moving parts underwater,
invented in 1967, has an outstanding resulting in significant savings in
international reputation and reference operating and maintenance costs.
list.
Worldwide Applications
The HELIXOR Unit is a sub-surface
mixing/aerating device, constructed of POLCON HELIXOR Systems have a
wide range of applications. There are • lake aeration
twelve (12) inch diameter molded
approximately 2,000 in operation • ice prevention -
polypropylene. It incorporates an
throughout the world. prevention of winter
integral monolithic helix component
fishkill
throughout its interior length. The units The HELIXOR Unit has been
• pH balancing -
are anchored vertically and are supplied incorporated into systems designed for:
industrial
with compressed air (or gas) at their
• treatment of industrial wastewater mixing, etc.
base. This creates a highly turbulent flow
• treatment of domestic sewage
of air (gas) and liquid. Treatment Systems range
• water quality improvement
from conventional
aerated lagoons and
HELIXOR Oxygenation Capacity concrete tanks or basins,
to systems installed
12–inch Diameter 305 mm Diameter within the receiving body
10 5
of water - (i.e. a portion
Test Conditions: th Test Conditions:
Dissolved Oxygen Zero ep Dissolved Oxygen Zero h of a lake, river, or harbor
9
rD pt
Temperature 20oC e Temperature 20oC De is used as a treatment
at e r
Helixor: 12" diameter 5' long
ft.
W Helixor: 0.305M diameter x 1.5M at
W facility). HELIXORS offer
OXYGEN TRANSFER LBS / HELIXOR / HOUR

8
3 th 4
OXYGEN TRANSFER KG / HELIXOR / HOUR

2 ep 7M
rD p th
a t e
r De flexibility of design and few
e
7 t. W at
2 0f W restrictions as to basin depth or
6M
6 3 geometry.
pth h
rD
e ep t POLCON’s Water Quality Improvement
5
a te rD
f t. W ate
15 MW & Eutrophication Reversal Systems are
4 .5
4
pth 2
th designed to create and maintain ideal
a te r De Dep
t. W Water environments for the growth of desirable
10 f 3M
3
and healthy aquatic life and, in colder
2 1 climes, the prevention of ice formation
and winter fishkill.
1

0 0
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
FREE AIR FLOW (CFM) FREE AIR FLOW (Litres / Sec.)

Design data are based on controlled studies by independent authorities at:


• University of Iowa - P.F. Morgan Laboratory
• Aware Inc. - a recognized authority in the field
• Gerry Shell Environmental Engineering Inc. - also a recognized authority
• University of Montreal, Quebec, Canada
Why Choose the POLCON HELIXOR System?
Higher operating efficiency and No need for fixed
lower capital costs: structures:

Oxygen transfer from the compressed air POLCON HELIXORS


to the effluent improves as the depth of are mounted on concrete
the HELIXOR System increases. anchors on the lagoon or
basin floor. When the
Since our System can operate in any
units are to be installed
water depth from five (5) feet upwards,
in a concrete tank, the
there are capital savings as depth
HELIXOR support
increases because less land is required,
brackets are simply
fewer HELIXORS are needed and the
bolted to the concrete Aerated lagoon, British Columbia, Canada
size of the underwater piping is reduced.
floor.

Optimum treatment
efficiency:

POLCON HELIXOR
Systems distribute the
aeration and mixing
units uniformly within
the aeration basin. This
allows effective and
efficient treatment
throughout the facility,
without sludge-bank
formation.
Facultative lagoons:

If facultative lagoon
technology is specified,
POLCON HELIXORS Activated sludge plant, Belgium.
may be secured by a
tether-type system which positions the water depth which results in the warmer
HELIXOR Units at a predetermined bottom water being pumped to
height above the basin floor, thus the surface.
Lower operating costs:
deliberately promoting the anaerobic/ No corrosion:
Flexibility of loading saves operating aerobic layers necessary for this process
costs when the oxygen demand varies. variant. The underwater components of the
POLCON HELIXOR System are
When the design oxygen demand is No water hazards: fabricated of corrosive-resistant
decreased, the air flow to the materials.
POLCON HELIXORS have no moving
HELIXOR ® Units can be reduced
parts underwater requiring maintenance
automatically, while still maintaining
and no electrical connections.
uniform circulation throughout
the basin. Since the HELIXOR System is
submerged, it is not subject to icing
under normal loading conditions. This
is due to the option of selecting a greater
Algeria
POLCON AERATION SYSTEMS INC. Australia
431 Mountain Highway, Suite 3 Belgium
North Vancouver, British Columbia, CANADA V7J 2L1
Telephone: (604) 986-9414 Fax: (604) 986-5377
Brazil
E-mail: polcon@sanitherm.com Brunei
Web Site: http://www.sanitherm.com
Canada
China
Croatia
LIXOR Ins Denmark
HE t ®
El Salvador
al
N

lat
POLCO

England
ions Around the World

Finland
France
Germany
Greece
Iran
Ireland
Israel
Italy
Japan
Malaysia
Nigeria
Norway
The representative in your area
Poland
Saudi Arabia
South Africa
Spain
Sweden
United States
Venezuela