PA FAN#1A 17 4.1 H MOTOR DE N HFC at motor DE brg. May pl.

be greased.
ID FAN#1B 43 2.4 H FAN INBOARD N IGV:100%.
BRG.
TDBFP#6B 65 17.7 H MP NDE BRG A Speed:5139rpm. Previous max.was
[FLOW:920TPH] 78/21.2 at 950TPH.on 04/03/2020.
CRUSHER#8 62 2.0 V CRUSHER NDE N Measured on 18/03/2020.Without
BRG. hammer. Vibration reduced from
152/4.8 to 62/2.0 after
dynamic balancing.
CLINKER GRINDER#1B 18 7.3 A MOTOR DE N Vibration reduced from 51/12.4
to normal .Abnormal sound
from fluid coupling ,may pl.
be checked.
FD FAN#2B 40 3.2 H MOTOR NDE N
ID FAN#4B 20 0.6 H MOTOR NDE N IGV:35%.
[SCOOP:60%]
BOWL MILL#1C [COAL 08 1.8 V MOTOR DE N
FLOW:33TPH]
BOWL MILL#2B [COAL 22 1.8 H MOTOR DE N
FLOW:29TPH]
BOWL MILL#2F [COAL 18 1.4 H WORM SHAFT N
FLOW:31TPH] NDE
BOWL MILL#3A [COAL 11 3.5 H MOTOR DE N
FLOW:32TPH]
BOWL MILL#3B [COAL 26 1.2 A WORM SHAFT N
FLOW:30TPH] DE
BOWL MILL#3D [COAL 10 5.3 V MOTOR DE N
FLOW:30TPH]
BOWL MILL#3E [COAL 15 3.7 H MOTOR DE N
FLOW:30TPH]
BOWL MILL#3F [COAL 12 1.7 V MOTOR NDE N
FLOW:30TPH]
CLINKER GRINDER#3A 07 15.1 A GB OUTPUT A Vibration is in alarm range
NDE (limit:150/12.0). Probable
cause:-i)Misalignmernt
CLINKER GRINDER#3B 20 6.5 H MOTOR NDE N
SCRAPPER CONV.#3A 180 15.1 H MOTOR NDE A Abnormal sound observed from
coupling. Vibration is in
alarm range(limit 120/12.0).
Probable cause:-
i)Misalignment(fluid coupling
may also be checked)

ESP AHU 296 12.8 A MOTOR DE N


BLOWER#2(U-6)
-------------------------------------------------------------------------------------------