You are on page 1of 50

CAPACITIES AND

SPECIFICATIONS
E2.00-3.20XM (E45-65XM, E45-65XM 2) [F108];
J2.00-3.20XM (J40-65XM, J40-65XM 2) [A216];
N30XMH, N30XMH 2 [C210]

PART NO. 897641 8000 SRM 561


SAFETY PRECAUTIONS
MAINTENANCE AND REPAIR
• When lifting parts or assemblies, make sure all slings, chains, or cables are correctly
fastened, and that the load being lifted is balanced. Make sure the crane, cables, and
chains have the capacity to support the weight of the load.

• Do not lift heavy parts by hand, use a lifting mechanism.

• Wear safety glasses.

• DISCONNECT THE BATTERY CONNECTOR before doing any maintenance or repair


on electric lift trucks.

• Disconnect the battery ground cable on internal combustion lift trucks.

• Always use correct blocks to prevent the unit from rolling or falling. See HOW TO PUT
THE LIFT TRUCK ON BLOCKS in the Operating Manual or the Periodic Mainte-
nance section.

• Keep the unit clean and the working area clean and orderly.

• Use the correct tools for the job.

• Keep the tools clean and in good condition.

• Always use HYSTER APPROVED parts when making repairs. Replacement parts
must meet or exceed the specifications of the original equipment manufacturer.

• Make sure all nuts, bolts, snap rings, and other fastening devices are removed before
using force to remove parts.

• Always fasten a DO NOT OPERATE tag to the controls of the unit when making repairs,
or if the unit needs repairs.

• Be sure to follow the WARNING and CAUTION notes in the instructions.

• Gasoline, Liquid Petroleum Gas (LPG), Compressed Natural Gas (CNG), and Diesel fuel
are flammable. Be sure to follow the necessary safety precautions when handling these
fuels and when working on these fuel systems.

• Batteries generate flammable gas when they are being charged. Keep fire and sparks
away from the area. Make sure the area is well ventilated.

NOTE: The following symbols and words indicate safety information in this
manual:

WARNING
Indicates a condition that can cause immediate death or injury!

CAUTION
Indicates a condition that can cause property damage!
Capacities and Specifications Table of Contents

TABLE OF CONTENTS

Counterweights .................................................................................................................................................. 1
Hydraulic System............................................................................................................................................... 1
Wheels and Tires................................................................................................................................................ 2
Battery Specifications........................................................................................................................................ 3
E2.00-3.20XM (E45-65XM, E45-65XM 2, N30XMH, N30XMH 2)................................................................. 3
J2.00-3.20XM (J40-65XM, J40-65XM 2)........................................................................................................ 4
Capacities ........................................................................................................................................................... 5
Movement Rates (Maximum) for Tilt Cylinders .............................................................................................. 5
Mast Speeds ....................................................................................................................................................... 6
E45-65XM Mast Speeds (36 or 48 Volt) Americas ....................................................................................... 6
E40-65XM, E40-65XM 2, N30XMH 2 Mast Speeds (36 or 48 Volt) Americas............................................... 12
E2.00-3.20XM Mast Speeds (72 or 80 Volt) Europe ..................................................................................... 17
E2.00-3.20XM, E2.00-3.20XM 2 Mast Speeds (72 or 80 Volt) Europe.......................................................... 23
J40-65XM Mast Speeds (36 or 48 Volt) Americas ........................................................................................ 26
J40-65XM, J40-65XM 2 Mast Speeds (36 or 48 Volt) Americas ................................................................... 30
J2.00-3.20XM Mast Speeds (72 or 80 Volt) Europe ..................................................................................... 33
Torque Specifications ......................................................................................................................................... 41
Frame ............................................................................................................................................................. 41
Drive Axle, Speed Reducer, and Differential E.200-3.20XM (E45-65XM, E45-65XM 2 and
N30XMH, N30XMH 2).................................................................................................................................... 41
Drive Axle, Speed Reducer, and Differential J2.00-3.20XM (J40-65XM, J40-65XM 2) .............................. 41
Steering Axle E2.00-3.20XM (E45-65XM, E45-65XM 2 and N30XMH, N30XMH 2)................................... 42
Steering Axle J2.00-3.20XM (J40-65XM, J40-65XM 2) ................................................................................ 42
Masts .............................................................................................................................................................. 42
Seat Brake...................................................................................................................................................... 42
Adhesives and Sealants ..................................................................................................................................... 43

This section is for the following models:

E2.00-3.20XM (E45-65XM, E45-65XM 2) [F108];


J2.00-3.20XM (J40-65XM, J40-65XM 2) [A216];
N30XMH, N30XMH 2 [C210]

©2003 HYSTER COMPANY i


"THE
QUALITY
KEEPERS"

HYSTER
APPROVED
PARTS
8000 SRM 561 Hydraulic System

Counterweights
Weight + 50 kg
Model * mm (* in.) (110 lb)
0 kg (0 lb)
E2.00XM and E2.50XM 700 mm (27.6 in.)
E2.50XM (E50XM and E50XM 2) 847 mm (33.3 in.) 544 kg (1200 lb)
E3.00XM 1015 mm (40.0 in.)
(E45XM and E45XM 2) 700 mm (27.6 in.)
(E55XM, E55XM 2) and E2.50XM (E65XM, E65XM 2), 847 mm (33.3 in.)
770 kg (1700 lb)
E3.00XM
E3.20XM and (N30XMH, N30XMH 2) 1015 mm (40.0 in.)
(E50XM, E50XM 2) and E2.50XM 700 mm (27.6 in.)
976 kg (2152 lb)
(E60XM, E60XM 2) and E3.00XM 847 mm (33.3 in.)
J2.00XM and J2.50XM (J40XM, J40XM 2 and J50XM, 717 mm (28.2 in.)
J50XM 2)
678 kg (1495 lb)
J2.50XM and J3.00XM (J50XM, J50XM 2 and J60XM, 861 mm (33.9 in.)
J60XM 2)
J3.20XM and (J65XM, J65XM 2) 861 mm (33.9 in.) 749 kg (1651 lb)
*Approximate battery compartment lengths (identifies frame size).

Hydraulic System
Item Specification
Relief Pressure, Lift System
E2.00-3.20XM (E45-65XM, E45-65XM 2) and (N30XMH, 21.7 ±0.7 MPa (3100 ±100 psi)
N30XMH 2)
J2.00-3.20XM (J40-65XM, J40-65XM 2) 21.0 ±0.7 MPa (3000 ±100 psi)
Relief Pressure, Tilt System
With Auxiliary Relief Valve 15.75 ±0.7 MPa (2250 ±100 psi)
Without Auxiliary Relief Valve 21.7 ±0.7 MPa (3100 ±100 psi)
Relief Pressure, Auxiliary 15.75 ±0.7 MPa (2250 ±100 psi)
Relief Pressure, Steering System 8620 ±345 kPa (1250 ±50 psi)
*Oil temperature 54 to 66 C (130 to 150 F).

1
Wheels and Tires 8000 SRM 561

Wheels and Tires


Item Specification
Torque - Wheel Nuts, Drive Tires 237 to 305 N•m
(175 to 225 lbf ft)
Torque - Wheel Nuts, Steering Tires 34 N•m (25 lbf ft)
E2.00-3.00XM (E45-65XM, E45-65XM 2 and N30XMH, N30XMH 2)
Drive Tires, Size Standard 21 × 7 × 15*
Drive Tires, Size Optional 21 × 8 × 15*
Steering Tires, Size Standard 16 × 5 × 10.5*
Steering Tires, Size Optional 16 × 6 × 10.5*
J2.00-3.20XM (J40-65XM, J40-65XM 2)
Drive Tires, Size Pneumatic 23 × 10-12 16 Ply
Drive Tires, Size Pneumatic Shaped Solid 23 × 10-12/8.0
Steering Tires, Size Pneumatic 18 × 7.00 × 8.00 16 Ply
Steering Tires, Size Pneumatic Shaped Solid 18 × 7.00-8/4.33
*Smooth, lug tread; standard and nonmarking, electric compound and for all models, smooth polyurethane.

2
8000 SRM 561 Battery Specifications

Battery Specifications
E2.00-3.20XM (E45-65XM, E45-65XM 2, N30XMH, N30XMH 2)
Minimum Battery Size Minimum/ Weight
Compartment Maximum
Model
Size
Length Width Minimum Maximum
Length × Width
E2.00XM, 985 kg 1453 kg
E2.50XM* 695 × 987 mm 681/691 mm (2172 lb) (3203 lb)
E45-50XM (27.4 × 38.8 in.) (26.8/27.2 in.) 1044 kg 1498 kg
(E45-50XM 2)* (2302 lb) (3302 lb)
E2.50XM, 1317 kg 1771 kg
E3.00XM* 842 × 987 mm 800/838 mm (2903 lb) (3904 lb)
978/983 mm
(E45-60XM, (33.2 × 38.8 in.) (31.5/33.0 in.)
(38.5/38.7 in.)
E45-60XM 2)*
E3.00-3.20XM 1553 kg 1998 kg
(E65XM, (3424 lb) (4405 lb)
E65XM 2) 1010 × 987 mm 1001/1006 mm
(39.8 × 38.8 in.) (39.4/39.6 in.)
(N30XMH,
N30XMH 2)
*Short Wheelbase
612 mm (24.1 in.) = maximum height for batteries with a cover.
579 mm (22.8 in.) = maximum height for batteries without a cover.
The tolerances of the battery compartment are +3 and 0 mm (+0.118 and 0 in.). The battery size column
shows the size range that will permit the battery to still fit into a battery compartment.
The battery compartment length is front to back. Width is side to side. The length dimension of the battery
must fit within the battery compartment side-to-side dimension with a clearance of 0 to 13 mm (0 to 0.5 in.)
maximum. Battery width must fit within the battery compartment front-to-back dimension.

WARNING
The battery must fit the battery compartment so that the battery restraint system will operate
correctly. Use only batteries with the correct length shown in this table. Adjust the spacer plate
and side spacers to prevent the battery from moving more than 13 mm (0.5 in.) forward or back-
ward.

3
Battery Specifications 8000 SRM 561

J2.00-3.20XM (J40-65XM, J40-65XM 2)


Battery Size
Min. Compartment Minimum/Maximum Maximum
Model
Size Length × Width Weight
Length Width
J2.00-2.50XM* - 72/80V
690 mm 1776 kg
(J40XM, J40XM 2, J50XM*, (27.2 in.) (3915 lb)
712 × 986 mm
J50XM 2*) - 36V
(28.0 × 38.8 in.)
(J40XM, J40XM 2, J50XM*, 686 mm 1790 kg
J50XM 2*) - 48V 982 mm (27.0 in.) (3946 lb)
(38.7 in.)
J2.50-3.20XM - 72/80V 805 mm 2127 kg
(J50-65XM, J50-65XM 2) - 36V 856 × 986 mm (31.7 in.) (4689 lb)
(33.7 × 38.8 in.)
(J50-65XM, J50-65XM 2) - 48V 835 mm 2209 kg
(32.9 in.) (4870 lb)
*Short Wheelbase
777 mm (30.6 in.) = maximum height for all batteries.
The tolerances of the battery compartment are +3 and 0 mm (+0.118 and 0 in.). The battery size column
shows the size range that will permit the battery to still fit into a battery compartment.
The battery compartment length is front to back. Width is side to side. The length dimension of the battery
must fit within the battery compartment side-to-side dimension with a clearance of 0 to 13 mm (0 to 0.5 in.)
maximum. Battery width must fit within the battery compartment front-to-back dimension.

WARNING
The battery must fit the battery compartment so that the battery restraint system will operate
correctly. Use only batteries with the correct length shown in this table. Adjust the spacer plate
and side spacers to prevent the battery from moving more than 13 mm (0.5 in.) forward or back-
ward.

4
8000 SRM 561 Movement Rates (Maximum) for Tilt Cylinders

Capacities
Item Specification
Hydraulic System (Full Mark on Dipstick)*
E2.00-3.20XM (E45-65XM, E45-65XM 2 and N30XMH, N30XMH 2) 23.0 liter (6.1 gal)
J2.00-3.20XM (J40-65XM, J40-65XM 2) 27.4 liter (7.23 gal)
Differential/Speed Reducer
E2.00-3.20XM (E45-65XM, E45-65XM 2 and N30XMH, N30XMH 2) 4.2 liter (8.8 pt)
J2.00-3.20XM (J40-65XM, J40-65XM 2) 3.7 liter (7.8 pt)
Brake Fluid 0.24 liter (0.5 pt)
Hydraulic Pump Capacities**
Large Lift Pump 19 cc/rev. (1.16 in. 3/rev.)
Small Lift Pumps 12 cc/rev. (0.73 in. 3/rev.)
Steering Pump 4.23 cc/rev. (0.26 in. 3/rev.)
*Check after all air is removed from the system and with the mast fully lowered.
**Oil temperature at 54 to 66 C (130 to 150 F)

Movement Rates (Maximum) for Tilt Cylinders


Hydraulic Oil Temperature/Mast Tilt Rate
Lift Truck Model 20 C (68 F) 60 C (140 F)
mm/min in/min mm/min in/min
All Models (Except N30XMH, N30XMH 2) 0.8 0.03 5.0 0.20

5
Mast Speeds 8000 SRM 561

Mast Speeds
E45-65XM MAST SPEEDS (36 OR 48 VOLT) AMERICAS
Contactor Controlled Standard Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.295 58 0.513 101
Stage 0.569 112 0.508 100
48 0.442 87 0.625 123
LFL
Two-
36 0.305 60 0.472 93
Stage 0.523 103 0.457 90
48 0.406 80 0.625 123
FFL
E45XM
Three-
36 0.310 61 0.462 91
Stage 0.538 106 0.467 92
48 0.396 78 0.610 120
FFL
Four-
36 0.290 57 0.452 89
Stage 0.447 88 0.411 81
48 0.401 79 0.569 112
FFL
Two-
36 0.284 56 0.513 101
Stage 0.574 113 0.508 100
48 0.376 74 0.625 123
LFL
Two-
36 0.295 58 0.472 93
Stage 0.538 106 0.457 90
48 0.391 77 0.625 123
FFL
E50XM
Three-
36 0.290 57 0.462 91
Stage 0.549 108 0.467 92
48 0.381 75 0.610 120
FFL
Four-
36 0.279 55 0.452 89
Stage 0.447 88 0.411 81
48 0.391 77 0.569 112
FFL
Two-
36 0.279 55 0.513 101
Stage 0.584 115 0.508 100
48 0.371 73 0.625 123
LFL
Two-
36 0.290 57 0.472 93
E55XM Stage 0.554 109 0.457 90
48 0.381 75 0.625 123
FFL
Three-
36 0.279 55 0.462 91
Stage 0.559 110 0.467 92
48 0.371 73 0.610 120
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

6
8000 SRM 561 Mast Speeds

Contactor Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.249 49 0.472 93
Stage 0.569 112 0.457 90
48 0.310 61 0.589 116
LFL
Two-
36 0.249 49 0.416 82
E60XM Stage 0.538 106 0.366 72
48 0.330 65 0.554 109
FFL
Three-
36 0.249 49 0.411 81
Stage 0.544 107 0.396 78
48 0.330 65 0.533 105
FFL
Two-
36 0.259 51 0.472 93
Stage 0.559 110 0.457 90
48 0.320 63 0.589 116
LFL
Two-
36 0.244 48 0.416 82
E65XM Stage 0.523 103 0.366 72
48 0.320 63 0.554 109
FFL
Three-
36 0.244 48 0.411 81
Stage 0.533 105 0.396 78
48 0.320 63 0.533 105
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

7
Mast Speeds 8000 SRM 561

SCR Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.279 55 0.420 83
Stage 0.569 112 0.508 100
48 0.361 71 0.559 110
LFL
Two-
36 0.284 56 0.442 87
Stage 0.523 103 0.457 90
48 0.381 75 0.589 116
FFL
E45XM
Three-
36 0.290 57 0.437 86
Stage 0.538 106 0.467 92
48 0.371 73 0.574 113
FFL
Four-
36 0.274 54 0.427 84
Stage 0.447 88 0.411 81
48 0.376 74 0.533 105
FFL
Two-
36 0.269 53 0.422 83
Stage 0.574 113 0.508 100
48 0.356 70 0.559 110
LFL
Two-
36 0.279 55 0.442 87
Stage 0.538 106 0.457 90
48 0.366 72 0.589 116
FFL
E50XM
Three-
36 0.274 54 0.437 86
Stage 0.549 108 0.467 92
48 0.361 71 0.589 113
FFL
Four-
36 0.264 52 0.437 84
Stage 0.447 88 0.411 81
48 0.366 72 0.533 105
FFL
Two-
36 0.259 51 0.422 83
Stage 0.584 115 0.508 100
48 0.340 67 0.559 110
LFL
Two-
36 0.274 54 0.442 87
E55XM Stage 0.554 109 0.457 90
48 0.361 71 0.589 116
FFL
Three-
36 0.264 52 0.437 86
Stage 0.559 110 0.467 92
48 0.351 69 0.589 113
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

8
8000 SRM 561 Mast Speeds

SCR Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.234 46 0.376 74
Stage 0.569 112 0.457 90
48 0.305 60 0.518 102
LFL
Two-
36 0.234 46 0.391 77
E60XM Stage 0.538 106 0.366 72
48 0.310 61 0.518 102
FFL
Three-
36 0.234 46 0.386 76
Stage 0.544 107 0.396 78
48 0.310 61 0.503 99
FFL
Two-
36 0.224 44 0.376 74
Stage 0.559 110 0.457 90
48 0.295 58 0.518 102
LFL
Two-
36 0.229 45 0.391 77
E65XM Stage 0.523 103 0.366 72
48 0.300 59 0.518 102
FFL
Three-
36 0.229 45 0.386 76
Stage 0.533 105 0.396 78
48 0.300 59 0.503 99
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

9
Mast Speeds 8000 SRM 561

Contactor Controlled Standard Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.218 43 0.345 68
Stage 0.569 112 0.508 100
48 0.290 57 0.457 90
LFL
Two-
36 0.229 45 0.356 70
Stage 0.523 103 0.457 90
48 0.305 60 0.472 93
FFL
E45XM
Three-
36 0.224 44 0.351 69
Stage 0.538 106 0.467 92
48 0.295 58 0.467 92
FFL
Four-
36 0.239 47 0.345 68
Stage 0.447 88 0.411 81
48 0.310 61 0.437 86
FFL
Two-
36 0.213 42 0.345 68
Stage 0.574 113 0.508 100
48 0.279 55 0.457 90
LFL
Two-
36 0.224 44 0.356 70
Stage 0.538 106 0.457 90
48 0.295 58 0.472 93
FFL
E50XM
Three-
36 0.218 43 0.351 69
Stage 0.549 108 0.467 92
48 0.290 57 0.467 92
FFL
Four-
36 0.234 46 0.345 68
Stage 0.447 88 0.411 81
48 0.300 59 0.437 86
FFL
Two-
36 0.208 41 0.345 68
Stage 0.584 115 0.508 100
48 0.274 54 0.457 90
LFL
Two-
36 0.218 43 0.356 70
E55XM Stage 0.554 109 0.457 90
48 0.284 56 0.472 93
FFL
Three-
36 0.213 42 0.351 69
Stage 0.559 110 0.467 92
48 0.279 55 0.467 92
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

10
8000 SRM 561 Mast Speeds

Contactor Controlled Standard Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.183 36 0.305 60
Stage 0.569 112 0.457 90
48 0.244 48 0.406 80
LFL
Two-
36 0.188 37 0.310 61
E60XM Stage 0.538 106 0.366 72
48 0.249 49 0.417 82
FFL
Three-
36 0.188 37 0.310 61
Stage 0.544 107 0.396 78
48 0.249 49 0.411 81
FFL
Two-
36 0.178 35 0.305 60
Stage 0.559 110 0.457 90
48 0.239 47 0.406 80
LFL
Two-
36 0.183 36 0.310 61
E65XM Stage 0.523 103 0.366 72
48 0.244 48 0.417 82
FFL
Three-
36 0.183 36 0.310 61
Stage 0.533 105 0.396 78
48 0.244 48 0.411 81
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

11
Mast Speeds 8000 SRM 561

E40-65XM, E40-65XM 2, N30XMH 2 MAST SPEEDS (36 OR 48 VOLT) AMERICAS


190 mm (7.5 in.) Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.310 61 0.513 101
Stage 0.559 110 0.508 100
48 0.417 82 0.625 123
LFL
Two-
36 0.315 62 0.472 93
Stage 0.508 100 0.457 90
48 0.417 82 0.625 123
E40XM FFL
E40XM 2 Three-
36 0.310 61 0.462 91
Stage 0.528 104 0.467 92
48 0.406 80 0.610 120
FFL
Four-
36 0.300 59 0.452 89
Stage 0.447 88 0.411 81
48 0.417 82 0.569 112
FFL
Two-
36 0.295 58 0.513 101
Stage 0.569 112 0.508 100
48 0.442 87 0.625 123
LFL
Two-
36 0.305 60 0.472 93
Stage 0.523 103 0.457 90
48 0.406 80 0.625 123
E45XM FFL
E45XM 2 Three-
36 0.310 61 0.462 91
Stage 0.538 106 0.467 92
48 0.396 78 0.610 120
FFL
Four-
36 0.290 57 0.452 89
Stage 0.447 88 0.411 81
48 0.401 79 0.569 112
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

12
8000 SRM 561 Mast Speeds

190 mm (7.5 in.) Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.284 56 0.513 101
Stage 0.574 113 0.508 100
48 0.376 74 0.625 123
LFL
Two-
36 0.295 58 0.472 93
Stage 0.538 106 0.457 90
48 0.391 77 0.625 123
E50XM FFL
E50XM 2 Three-
36 0.290 57 0.462 91
Stage 0.549 108 0.467 92
48 0.381 75 0.610 120
FFL
Four-
36 0.279 55 0.452 89
Stage 0.447 88 0.411 81
48 0.391 77 0.610 112
FFL
Two-
36 0.279 55 0.513 101
Stage 0.584 115 0.508 100
48 0.371 73 0.625 123
LFL
Two-
E55XM 36 0.290 57 0.472 93
Stage 0.554 109 0.457 90
E55XM 2 48 0.381 75 0.625 123
FFL
Three-
36 0.279 55 0.462 91
Stage 0.559 110 0.467 92
48 0.371 73 0.610 120
FFL
Two-
36 0.249 49 0.513 101
Stage 0.569 112 0.457 90
48 0.310 61 0.625 123
LFL
Two-
E60XM 36 0.249 49 0.472 93
Stage 0.538 106 0.366 72
E60XM 2 48 0.330 65 0.625 123
FFL
Three-
36 0.249 49 0.462 91
Stage 0.544 107 0.396 78
48 0.330 65 0.610 120
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

13
Mast Speeds 8000 SRM 561

190 mm (7.5 in.) Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.259 51 0.513 101
Stage 0.559 110 0.457 90
48 0.320 63 0.625 123
LFL
Two-
E65XM 36 0.244 48 0.472 93
Stage 0.523 103 0.366 72
E65XM 2 48 0.320 63 0.625 123
FFL
Three-
36 0.244 48 0.462 91
Stage 0.533 105 0.396 78
48 0.320 63 0.610 120
FFL
Three-
36 N/A N/A N/A N/A
N30XMH 2 Stage 0.462 91 0.462 91
48 N/A N/A N/A N/A
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

14
8000 SRM 561 Mast Speeds

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.224 44 0.345 68
Stage 0.559 110 0.508 100
48 0.300 59 0.457 90
LFL
Two-
36 0.234 46 0.357 70
Stage 0.508 100 0.457 90
48 0.310 61 0.472 93
E40XM FFL
E40XM 2 Three-
36 0.229 45 0.351 69
Stage 0.528 104 0.467 92
48 0.305 60 0.467 92
FFL
Four-
36 0.249 49 0.345 68
Stage 0.447 88 0.411 81
48 0.320 63 0.437 86
FFL
Two-
36 0.218 43 0.345 68
Stage 0.569 112 0.508 100
48 0.290 57 0.457 90
LFL
Two-
36 0.229 45 0.357 70
Stage 0.523 103 0.457 90
48 0.305 60 0.472 93
E45XM FFL
E45XM 2 Three-
36 0.224 44 0.351 69
Stage 0.538 106 0.467 92
48 0.295 58 0.467 92
FFL
Four-
36 0.239 47 0.345 68
Stage 0.447 88 0.411 81
48 0.310 61 0.437 86
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

15
Mast Speeds 8000 SRM 561

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.213 42 0.345 68
Stage 0.547 113 0.508 100
48 0.279 55 0.457 90
LFL
Two-
36 0.224 44 0.356 70
Stage 0.538 106 0.457 90
48 0.295 58 0.472 93
E50XM FFL
E50XM 2 Three-
36 0.218 43 0.351 69
Stage 0.549 108 0.467 92
48 0.290 57 0.467 92
FFL
Four-
36 0.234 46 0.345 68
Stage 0.447 88 0.411 81
48 0.300 59 0.437 86
FFL
Two-
36 0.208 41 0.345 68
Stage 0.584 115 0.508 100
48 0.274 54 0.457 90
LFL
Two-
E55XM 36 0.218 43 0.356 70
Stage 0.554 109 0.457 90
E55XM 2 48 0.284 56 0.457 90
FFL
Three-
36 0.213 42 0.351 69
Stage 0.559 110 0.467 92
48 0.279 55 0.467 92
FFL
Two-
36 0.183 36 0.305 60
Stage 0.569 112 0.457 90
48 0.244 48 0.406 80
LFL
Two-
E60XM 36 0.188 37 0.310 61
Stage 0.538 106 0.366 72
E60XM 2 48 0.249 49 0.417 82
FFL
Three-
36 0.188 37 0.310 61
Stage 0.544 107 0.396 78
48 0.249 49 0.411 81
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

16
8000 SRM 561 Mast Speeds

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.173 34 0.305 60
Stage 0.559 110 0.457 90
48 0.239 47 0.406 80
LFL
Two-
E65XM 36 0.183 36 0.310 61
Stage 0.523 103 0.366 72
E65XM 2 48 0.244 48 0.417 82
FFL
Three-
36 0.183 36 0.310 61
Stage 0.533 105 0.396 78
48 0.244 48 0.411 81
FFL
Three-
36 N/A N/A N/A N/A
N30XMH 2 Stage 0.462 91 0.462 91
48 N/A N/A N/A N/A
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

E2.00-3.20XM MAST SPEEDS (72 OR 80 VOLT) EUROPE


Contactor Controlled Standard Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.376 0.544
0.559 0.508
80 0.422 0.605
Two-Stage FFL 72 0.396 0.569
0.508 0.457
80 0.442 0.635
E2.00XM
Three-Stage FFL 72 0.386 0.559
0.528 0.467
80 0.432 0.625
Four-Stage FFL 72 0.330 0.483
0.447 0.411
80 0.366 0.538
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

17
Mast Speeds 8000 SRM 561

Contactor Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.345 0.544
0.574 0.508
80 0.391 0.605
Two-Stage FFL 72 0.366 0.569
0.538 0.457
80 0.411 0.635
E2.50XM
Three-Stage FFL 72 0.356 0.559
0.549 0.467
80 0.401 0.625
Four-Stage FFL 72 0.315 0.483
0.447 0.411
80 0.351 0.538
Two-Stage LFL 72 0.300 0.488
0.569 0.457
80 0.335 0.544
Two-Stage FFL 72 0.310 0.503
E3.00XM 0.538 0.366
80 0.345 0.564
Three-Stage FFL 72 0.310 0.503
0.544 0.396
80 0.345 0.559
Two-Stage LFL 72 0.295 0.488
0.559 0.457
80 0.330 0.544
Two-Stage FFL 72 0.300 0.503
E3.20XM 0.523 0.366
80 0.335 0.564
Three-Stage FFL 72 0.300 0.503
0.533 0.396
80 0.335 0.559
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

18
8000 SRM 561 Mast Speeds

SCR Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.356 0.513
0.559 0.508
80 0.396 0.569
Two-Stage FFL 72 0.381 0.533
0.508 0.457
80 0.417 0.599
E2.00XM
Three-Stage FFL 72 0.361 0.523
0.528 0.467
80 0.406 0.589
Four-Stage FFL 72 0.310 0.452
0.447 0.411
80 0.345 0.508
Two-Stage LFL 72 0.325 0.513
0.574 0.508
80 0.366 0.569
Two-Stage FFL 72 0.345 0.533
0.538 0.457
80 0.386 0.599
E2.50XM
Three-Stage FFL 72 0.335 0.523
0.549 0.467
80 0.376 0.589
Four-Stage FFL 72 0.295 0.452
0.447 0.411
80 0.330 0.508
Two-Stage LFL 72 0.279 0.457
0.569 0.457
80 0.315 0.513
Two-Stage FFL 72 0.290 0.472
E3.00XM 0.538 0.366
80 0.325 0.528
Three-Stage FFL 72 0.290 0.472
0.544 0.396
80 0.325 0.523
Two-Stage LFL 72 0.279 0.457
0.559 0.457
80 0.310 0.513
Two-Stage FFL 72 0.279 0.472
E3.20XM 0.523 0.366
80 0.315 0.528
Three-Stage FFL 72 0.279 0.472
0.533 0.396
80 0.315 0.523
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

19
Mast Speeds 8000 SRM 561

Contactor Controlled Standard Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.290 0.411
0.559 0.508
80 0.310 0.462
Two-Stage FFL 72 0.300 0.432
0.508 0.457
80 0.330 0.478
E2.00XM
Three-Stage FFL 72 0.295 0.422
0.528 0.467
80 0.320 0.472
Four-Stage FFL 72 0.310 0.406
0.447 0.411
80 0.340 0.447
Two-Stage LFL 72 0.274 0.411
0.574 0.508
80 0.295 0.462
Two-Stage FFL 72 0.279 0.432
0.538 0.457
80 0.305 0.478
E2.50XM
Three-Stage FFL 72 0.279 0.422
0.549 0.467
80 0.300 0.472
Four-Stage FFL 72 0.295 0.406
0.447 0.411
80 0.325 0.477
Two-Stage LFL 72 0.229 0.371
0.569 0.457
80 0.259 0.411
Two-Stage FFL 72 0.234 0.381
E3.00XM 0.538 0.366
80 0.259 0.422
Three-Stage FFL 72 0.234 0.366
0.544 0.396
80 0.259 0.422
Two-Stage LFL 72 0.229 0.371
0.559 0.457
80 0.254 0.411
Two-Stage FFL 72 0.229 0.381
E3.20XM 0.523 0.366
80 0.254 0.422
Three-Stage FFL 72 0.229 0.366
0.533 0.396
80 0.254 0.422
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm
(20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

20
8000 SRM 561 Mast Speeds

Contactor Controlled Optional Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.396 0.554
0.559 0.508
80 0.442 0.620
Two-Stage FFL 72 0.406 0.579
0.508 0.457
80 0.457 0.645
E2.00XM
Three-Stage FFL 72 0.401 0.569
0.528 0.467
80 0.452 0.635
Four-Stage FFL 72 0.351 0.483
0.447 0.411
80 0.391 0.538
Two-Stage LFL 72 0.371 0.554
0.574 0.508
80 0.417 0.620
Two-Stage FFL 72 0.386 0.579
0.538 0.457
80 0.432 0.645
E2.50XM
Three-Stage FFL 72 0.376 0.569
0.549 0.467
80 0.422 0.635
Four-Stage FFL 72 0.330 0.483
0.447 0.411
80 0.371 0.538
Two-Stage LFL 72 0.320 0.498
0.569 0.457
80 0.361 0.554
Two-Stage FFL 72 0.325 0.513
E3.00XM 0.538 0.366
80 0.366 0.574
Three-Stage FFL 72 0.325 0.508
0.544 0.396
80 0.366 0.569
Two-Stage LFL 72 0.315 0.498
0.559 0.457
80 0.351 0.554
Two-Stage FFL 72 0.320 0.513
E3.20XM 0.523 0.366
80 0.361 0.574
Three-Stage FFL 72 0.320 0.508
0.533 0.396
80 0.356 0.569
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

21
Mast Speeds 8000 SRM 561

SCR Controlled Optional Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.371 0.518
0.559 0.508
80 0.417 0.584
Two-Stage FFL 72 0.381 0.543
0.508 0.457
80 0.432 0.605
E2.00XM
Three-Stage FFL 72 0.376 0.533
0.528 0.467
80 0.427 0.599
Four-Stage FFL 72 0.330 0.452
0.447 0.411
80 0.366 0.508
Two-Stage LFL 72 0.350 0.518
0.574 0.508
80 0.391 0.584
Two-Stage FFL 72 0.361 0.544
0.538 0.457
80 0.406 0.605
E2.50XM
Three-Stage FFL 72 0.356 0.533
0.549 0.467
80 0.396 0.599
Four-Stage FFL 72 0.310 0.452
0.447 0.411
80 0.350 0.508
Two-Stage LFL 72 0.300 0.467
0.569 0.457
80 0.340 0.518
Two-Stage FFL 72 0.305 0.483
E3.00XM 0.538 0.366
80 0.345 0.538
Three-Stage FFL 72 0.305 0.478
0.544 0.396
80 0.345 0.533
Two-Stage LFL 72 0.295 0.467
0.559 0.457
80 0.330 0.518
Two-Stage FFL 72 0.300 0.483
E3.20XM 0.523 0.366
80 0.340 0.538
Three-Stage FFL 72 0.300 0.478
0.533 0.396
80 0.335 0.533
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

22
8000 SRM 561 Mast Speeds

E2.00-3.20XM, E2.00-3.20XM 2 MAST SPEEDS (72 OR 80 VOLT) EUROPE


190 mm (7.5 in.) Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.376 0.544
0.559 0.508
80 0.422 0.605
Two-Stage FFL 72 0.396 0.569
0.508 0.457
E2.00XM 80 0.442 0.635
E2.00XM 2 Three-Stage FFL 72 0.386 0.559
0.528 0.467
80 0.432 0.625
Four-Stage FFL 72 0.330 0.483
0.447 0.411
80 0.366 0.538
Two-Stage LFL 72 0.345 0.544
0.574 0.508
80 0.391 0.605
Two-Stage FFL 72 0.366 0.569
0.538 0.457
E2.50XM 80 0.411 0.635
E2.50XM 2 Three-Stage FFL 72 0.356 0.559
0.549 0.467
80 0.401 0.625
Four-Stage FFL 72 0.315 0.483
0.447 0.411
80 0.351 0.538
Two-Stage LFL 72 0.300 0.488
0.569 0.457
80 0.335 0.544
E3.00XM Two-Stage FFL 72 0.310 0.503
0.538 0.366
E3.00XM 2 80 0.345 0.564
Three-Stage FFL 72 0.310 0.503
0.544 0.396
80 0.345 0.559
Two-Stage LFL 72 0.295 0.488
0.559 0.457
80 0.330 0.544
E3.20XM Two-Stage FFL 72 0.300 0.503
0.523 0.366
E3.20XM 2 80 0.335 0.564
Three-Stage FFL 72 0.300 0.503
0.533 0.396
80 0.335 0.559
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available.

23
Mast Speeds 8000 SRM 561

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.290 0.411
0.559 0.508
80 0.310 0.462
Two-Stage FFL 72 0.300 0.432
0.508 0.457
E2.00XM 80 0.330 0.478
E2.00XM 2 Three-Stage FFL 72 0.295 0.422
0.528 0.467
80 0.320 0.472
Four-Stage FFL 72 0.310 0.406
0.447 0.411
80 0.340 0.447
Two-Stage LFL 72 0.274 0.411
0.574 0.508
80 0.295 0.462
Two-Stage FFL 72 0.279 0.432
0.538 0.457
E2.50XM 80 0.305 0.478
E2.50XM 2 Three-Stage FFL 72 0.279 0.422
0.549 0.467
80 0.300 0.472
Four-Stage FFL 72 0.295 0.406
0.447 0.411
80 0.325 0.477
Two-Stage LFL 72 0.229 0.371
0.569 0.457
80 0.259 0.411
E3.00XM Two-Stage FFL 72 0.234 0.381
0.538 0.366
E3.00XM 2 80 0.259 0.422
Three-Stage FFL 72 0.234 0.366
0.544 0.396
80 0.259 0.422
Two-Stage LFL 72 0.229 0.371
0.559 0.457
80 0.254 0.411
E3.20XM Two-Stage FFL 72 0.229 0.381
0.523 0.366
E3.20XM 2 80 0.254 0.422
Three-Stage FFL 72 0.229 0.366
0.533 0.396
80 0.254 0.422
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm
(20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

24
8000 SRM 561 Mast Speeds

203 or 190 mm (8.0 or 7.5 in.) Long Stack Motor and Small Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.396 0.554
0.559 0.508
80 0.442 0.620
Two-Stage FFL 72 0.406 0.579
0.508 0.457
E2.00XM 80 0.457 0.645
E2.00XM 2 Three-Stage FFL 72 0.401 0.569
0.528 0.467
80 0.452 0.635
Four-Stage FFL 72 0.351 0.483
0.447 0.411
80 0.391 0.538
Two-Stage LFL 72 0.371 0.554
0.574 0.508
80 0.417 0.620
Two-Stage FFL 72 0.386 0.579
0.538 0.457
E2.50XM 80 0.432 0.645
E2.50XM 2 Three-Stage FFL 72 0.376 0.569
0.549 0.467
80 0.422 0.635
Four-Stage FFL 72 0.330 0.483
0.447 0.411
80 0.371 0.538
Two-Stage LFL 72 0.320 0.498
0.569 0.457
80 0.361 0.554
E3.00XM Two-Stage FFL 72 0.325 0.513
0.538 0.366
E3.00XM 2 80 0.366 0.574
Three-Stage FFL 72 0.325 0.508
0.544 0.396
80 0.366 0.569
Two-Stage LFL 72 0.315 0.498
0.559 0.457
80 0.351 0.554
E3.20XM Two-Stage FFL 72 0.320 0.513
0.523 0.366
E3.20XM 2 80 0.361 0.574
Three-Stage FFL 72 0.320 0.508
0.533 0.396
80 0.356 0.569
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, GE long stack or BKB 203 mm (8.0 in.) pump
motor and 500 mm (20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

25
Mast Speeds 8000 SRM 561

J40-65XM MAST SPEEDS (36 OR 48 VOLT) AMERICAS


Contactor Controlled Standard Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.310 61 0.513 101
Stage 0.559 110 0.508 100
48 0.417 82 0.625 123
LFL
Two-
36 0.315 62 0.472 93
J40XM Stage 0.508 100 0.457 90
48 0.416 82 0.625 123
FFL
Three-
36 0.310 61 0.462 91
Stage 0.528 104 0.467 92
48 0.406 80 0.610 120
FFL
Two-
36 0.284 56 0.513 101
Stage 0.574 113 0.508 100
48 0.376 74 0.625 123
LFL
Two-
36 0.295 58 0.472 93
J50XM Stage 0.538 106 0.457 90
48 0.391 77 0.625 123
FFL
Three-
36 0.290 57 0.462 91
Stage 0.549 108 0.467 92
48 0.381 75 0.610 120
FFL
Two-
36 0.249 49 0.472 93
Stage 0.569 112 0.457 90
48 0.310 61 0.589 116
LFL
Two-
36 0.249 49 0.417 82
J60XM Stage 0.538 106 0.366 72
48 0.330 65 0.554 109
FFL
Three-
36 0.249 49 0.411 81
Stage 0.544 107 0.396 78
48 0.330 65 0.533 105
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

26
8000 SRM 561 Mast Speeds

Contactor Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.259 51 0.472 93
Stage 0.559 110 0.457 90
48 0.320 63 0.589 116
LFL
Two-
36 0.244 48 0.417 82
J65XM Stage 0.523 103 0.366 72
48 0.320 63 0.554 109
FFL
Three-
36 0.244 48 0.411 81
Stage 0.533 105 0.396 78
48 0.320 63 0.533 105
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

SCR Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.279 55 0.483 95
Stage 0.559 110 0.508 100
48 0.371 73 0.589 116
LFL
Two-
36 0.295 58 0442 87
J40XM Stage 0.508 100 0.457 90
48 0.391 77 0.589 116
FFL
Three-
36 0.290 57 0.437 86
Stage 0.528 104 0.467 92
48 0.381 75 0.574 113
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

27
Mast Speeds 8000 SRM 561

SCR Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.269 53 0.483 95
Stage 0.574 113 0.508 100
48 0.357 70 0.589 116
LFL
Two-
36 0.279 55 0.442 87
J50XM Stage 0.538 106 0.457 90
48 0.366 72 0.589 116
FFL
Three-
36 0.274 54 0.437 86
Stage 0.549 108 0.467 92
48 0.361 71 0.574 113
FFL
Two-
36 0.234 46 0.442 87
Stage 0.569 112 0.457 90
48 0.305 60 0.554 109
LFL
Two-
36 0.234 46 0.391 77
J60XM Stage 0.538 106 0.366 72
48 0.310 61 0.518 102
FFL
Three-
36 0.234 46 0.386 76
Stage 0.544 107 0.396 78
48 0.310 61 0.503 99
FFL
Two-
36 0.224 44 0.442 87
Stage 0.559 110 0.457 90
48 0.295 58 0.554 109
LFL
Two-
36 0.229 45 0.391 77
J65XM Stage 0.523 103 0.366 72
48 0.300 59 0.518 102
FFL
Three-
36 0.229 45 0.386 76
Stage 0.533 105 0.396 78
48 0.300 59 0.503 99
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

28
8000 SRM 561 Mast Speeds

Contactor Controlled Standard Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.218 43 0.345 68
Stage 0.559 110 0.508 100
48 0.290 57 0.457 90
LFL
Two-
36 0.229 45 0.356 70
J40XM Stage 0.508 100 0.457 90
48 0.305 60 0.472 93
FFL
Three-
36 0.224 44 0.351 69
Stage 0.528 104 0.467 92
48 0.295 58 0.467 92
FFL
Two-
36 0.213 42 0.345 68
Stage 0.574 113 0.508 100
48 0.279 55 0.457 90
LFL
Two-
36 0.224 44 0.356 70
J50XM Stage 0.538 106 0.457 90
48 0.295 58 0.472 93
FFL
Three-
36 0.218 43 0.351 69
Stage 0.549 108 0.467 92
48 0.290 57 0.467 92
FFL
Two-
36 0.183 36 0.305 60
Stage 0.569 112 0.457 90
48 0.244 48 0.406 80
LFL
Two-
36 0.188 37 0.310 61
J60XM Stage 0.538 106 0.366 72
48 0.249 49 0.417 82
FFL
Three-
36 0.188 37 0.310 61
Stage 0.544 107 0.396 78
48 0.249 49 0.411 81
FFL
Two-
36 0.178 35 0.305 60
Stage 0.559 110 0.457 90
48 0.239 47 0.406 80
LFL
Two-
36 0.183 36 0.310 61
J65XM Stage 0.523 103 0.366 72
48 0.244 48 0.417 82
FFL
Three-
36 0.183 36 0.310 61
Stage 0.533 105 0.396 78
48 0.244 48 0.411 81
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

29
Mast Speeds 8000 SRM 561

J40-65XM, J40-65XM 2 MAST SPEEDS (36 OR 48 VOLT) AMERICAS


190 mm (7.5 in.) Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.310 61 0.513 101
Stage 0.559 110 0.508 100
48 0.417 82 0.625 123
LFL
Two-
J40XM 36 0.315 62 0.472 93
Stage 0.508 100 0.457 90
J40XM 2 48 0.417 82 0.625 123
FFL
Three-
36 0.310 61 0.462 91
Stage 0.528 104 0.467 92
48 0.406 80 0.610 120
FFL
Two-
36 0.285 56 0.513 101
Stage 0.574 113 0.508 100
48 0.376 74 0.625 123
LFL
Two-
J50XM 36 0.295 58 0.472 93
Stage 0.538 106 0.457 90
J50XM 2 48 0.391 77 0.625 123
FFL
Three-
36 0.290 57 0.462 91
Stage 0.549 108 0.467 92
48 0.381 75 0.610 120
FFL
Two-
36 0.249 49 0.472 93
Stage 0.569 112 0.457 90
48 0.310 61 0.590 116
LFL
Two-
J60XM 36 0.249 49 0.417 82
Stage 0.538 106 0.366 72
J60XM 2 48 0.330 65 0.554 109
FFL
Three-
36 0.249 49 0.411 81
Stage 0.544 107 0.396 78
48 0.330 65 0.533 105
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

30
8000 SRM 561 Mast Speeds

190 mm (7.5 in.) Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.259 51 0.472 93
Stage 0.559 110 0.457 90
48 0.320 63 0.590 116
LFL
Two-
J65XM 36 0.244 48 0.417 82
Stage 0.523 103 0.366 72
J65XM 2 48 0.320 63 0.554 109
FFL
Three-
36 0.244 48 0.411 81
Stage 0.533 105 0.396 78
48 0.320 63 0.533 105
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm (24 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.224 44 0.345 68
Stage 0.559 110 0.508 100
48 0.300 59 0.457 90
LFL
Two-
J40XM 36 0.229 45 0.356 70
Stage 0.508 100 0.457 90
J40XM 2 48 0.310 61 0.472 93
FFL
Three-
36 0.229 45 0.351 69
Stage 0.528 104 0.467 92
48 0.305 60 0.467 92
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

31
Mast Speeds 8000 SRM 561

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec ft/min m/sec ft/min m/sec ft/min m/sec ft/min
Two-
36 0.213 42 0.345 68
Stage 0.574 113 0.508 100
48 0.279 55 0.457 90
LFL
Two-
J50XM 36 0.224 44 0.356 70
Stage 0.538 106 0.457 90
J50XM 2 48 0.295 58 0.472 93
FFL
Three-
36 0.218 43 0.351 69
Stage 0.549 108 0.467 92
48 0.290 57 0.467 92
FFL
Two-
36 0.183 36 0.305 60
Stage 0.569 112 0.457 90
48 0.234 46 0.406 80
LFL
Two-
J60XM 36 0.188 37 0.310 61
Stage 0.538 106 0.366 72
J60XM 2 48 0.249 49 0.417 82
FFL
Three-
36 0.188 37 0.310 61
Stage 0.544 107 0.396 78
48 0.249 49 0.411 81
FFL
Two-
36 0.178 35 0.305 60
Stage 0.559 110 0.457 90
48 0.239 47 0.406 80
LFL
Two-
J65XM 36 0.183 36 0.310 61
Stage 0.523 103 0.366 72
J65XM 2 48 0.244 48 0.417 82
FFL
Three-
36 0.183 36 0.310 61
Stage 0.533 105 0.396 78
48 0.244 48 0.411 81
FFL
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 610 mm
(24 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

32
8000 SRM 561 Mast Speeds

J2.00-3.20XM MAST SPEEDS (72 OR 80 VOLT) EUROPE


Cont. or Transistor Controlled Standard Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.376 0.544
0.569 0.508
80 0.422 0.605
Two-Stage FFL 72 0.396 0.569
J2.00XM 0.523 0.457
80 0.442 0.635
Three-Stage FFL 72 0.386 0.559
0.538 0.467
80 0.432 0.625
Two-Stage LFL 72 0.345 0.544
0.584 0.508
80 0.391 0.605
Two-Stage FFL 72 0.366 0.569
J2.50XM 0.554 0.457
80 0.411 0.635
Three-Stage FFL 72 0.356 0.559
0.559 0.467
80 0.401 0.625
Two-Stage LFL 72 0.300 0.488
0.559 0.457
80 0.335 0.544
Two-Stage FFL 72 0.310 0.503
J3.00XM 0.523 0.366
80 0.345 0.564
Three-Stage FFL 72 0.310 0.503
0.533 0.396
80 0.345 0.559
Two-Stage LFL 72 0.295 0.488
0.569 0.457
80 0.330 0.544
Two-Stage FFL 72 0.300 0.503
J3.20XM 0.533 0.366
80 0.335 0.564
Three-Stage FFL 72 0.300 0.503
0.544 0.396
80 0.335 0.559
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

33
Mast Speeds 8000 SRM 561

SCR Controlled Standard Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.356 0.513
0.569 0.508
80 0.396 0.569
Two-Stage FFL 72 0.371 0.533
J2.00XM 0.523 0.457
80 0.417 0.599
Three-Stage FFL 72 0.361 0.523
0.538 0.467
80 0.406 0.589
Two-Stage LFL 72 0.325 0.513
0.584 0.508
80 0.366 0.569
Two-Stage FFL 72 0.345 0.533
J2.50XM 0.554 0.457
80 0.386 0.599
Three-Stage FFL 72 0.335 0.523
0.559 0.467
80 0.376 0.589
Two-Stage LFL 72 0.279 0.457
0.558 0.457
80 0.315 0.513
Two-Stage FFL 72 0.290 0.472
J3.00XM 0.523 0.366
80 0.325 0.528
Three-Stage FFL 72 0.290 0.472
0.533 0.396
80 0.325 0.523
Two-Stage LFL 72 0.279 0.457
0.569 0.457
80 0.310 0.513
Two-Stage FFL 72 0.279 0.472
J3.20XM 0.533 0.366
80 0.315 0.528
Three-Stage FFL 72 0.279 0.457
0.544 0.396
80 0.315 0.523
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

34
8000 SRM 561 Mast Speeds

Cont. or Transistor Controlled Standard Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.290 0.411
0.559 0.508
80 0.310 0.462
Two-Stage FFL 72 0.300 0.432
J2.00XM 0.508 0.457
80 0.330 0.478
Three-Stage FFL 72 0.295 0.422
0.528 0.467
80 0.320 0.472
Two-Stage LFL 72 0.274 0.411
0.584 0.508
80 0.295 0.462
Two-Stage FFL 72 0.279 0.432
J2.50XM 0.554 0.457
80 0.305 0.478
Three-Stage FFL 72 0.279 0.422
0.559 0.467
80 0.300 0.472
Two-Stage LFL 72 0.229 0.371
0.559 0.457
80 0.259 0.411
Two-Stage FFL 72 0.234 0.381
J3.00XM 0.523 0.366
80 0.259 0.422
Three-Stage FFL 72 0.234 0.366
0.533 0.396
80 0.259 0.422
Two-Stage LFL 72 0.229 0.371
0.569 0.457
80 0.254 0.411
Two-Stage FFL 72 0.229 0.381
J3.20XM 0.533 0.366
80 0.254 0.422
Three-Stage FFL 72 0.229 0.366
0.544 0.396
80 0.254 0.422
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm
(20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

35
Mast Speeds 8000 SRM 561

Cont. or Transistor Controlled Optional Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.396 0.554
0.569 0.508
80 0.442 0.620
Two-Stage FFL 72 0.406 0.579
J2.00XM 0.523 0.457
80 0.457 0.645
Three-Stage FFL 72 0.401 0.569
0.538 0.467
80 0.452 0.635
Two-Stage LFL 72 0.371 0.554
0.584 0.508
80 0.416 0.620
Two-Stage FFL 72 0.386 0.579
J2.50XM 0.554 0.457
80 0.432 0.645
Three-Stage FFL 72 0.376 0.569
0.559 0.467
80 0.422 0.635
Two-Stage LFL 72 0.320 0.498
0.559 0.457
80 0.361 0.554
Two-Stage FFL 72 0.325 0.513
J3.00XM 0.523 0.366
80 0.366 0.574
Three-Stage FFL 72 0.325 0.508
0.533 0.396
80 0.366 0.569
Two-Stage LFL 72 0.315 0.498
0.569 0.457
80 0.351 0.554
Two-Stage FFL 72 0.320 0.513
J3.20XM 0.533 0.366
80 0.361 0.574
Three-Stage FFL 72 0.320 0.508
0.544 0.396
80 0.356 0.569
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) GE long stack or BKB 203 mm (8.0 in.)
pump motor and 500 mm (20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

36
8000 SRM 561 Mast Speeds

SCR Controlled Optional Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.370 0.518
0.569 0.508
80 0.417 0.584
Two-Stage FFL 72 0.381 0.543
J2.00XM 0.523 0.457
80 0.432 0.605
Three-Stage FFL 72 0.376 0.533
0.538 0.467
80 0.427 0.599
Two-Stage LFL 72 0.351 0.518
0.584 0.508
80 0.391 0.584
Two-Stage FFL 72 0.361 0.544
J2.50XM 0.554 0.457
80 0.406 0.605
Three-Stage FFL 72 0.356 0.533
0.559 0.467
80 0.396 0.599
Two-Stage LFL 72 0.300 0.467
0.558 0.457
80 0.340 0.518
Two-Stage FFL 72 0.305 0.483
J3.00XM 0.523 0.366
80 0.345 0.538
Three-Stage FFL 72 0.305 0.478
0.533 0.396
80 0.345 0.533
Two-Stage LFL 72 0.295 0.467
0.569 0.457
80 0.330 0.518
Two-Stage FFL 72 0.300 0.483
J3.20XM 0.533 0.366
80 0.340 0.538
Three-Stage FFL 72 0.300 0.478
0.544 0.396
80 0.335 0.533
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) GE long stack or BKB 203 mm (8.0 in.)
pump motor and 500 mm (20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values.

37
Mast Speeds 8000 SRM 561

190 mm (7.5 in.) Motor and Large Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.376 0.544
0.569 0.508
80 0.422 0.605
Two-Stage FFL 72 0.396 0.569
J2.00XM 0.523 0.457
80 0.442 0.635
Three-Stage FFL 72 0.386 0.559
0.538 0.467
80 0.432 0.625
Two-Stage LFL 72 0.345 0.544
0.584 0.508
80 0.391 0.605
Two-Stage FFL 72 0.366 0.569
J2.50XM 0.554 0.457
80 0.411 0.635
Three-Stage FFL 72 0.356 0.559
0.559 0.467
80 0.401 0.625
Two-Stage LFL 72 0.300 0.488
0.559 0.457
80 0.335 0.544
Two-Stage FFL 72 0.310 0.503
J3.00XM 0.523 0.366
80 0.345 0.564
Three-Stage FFL 72 0.310 0.503
0.533 0.396
80 0.345 0.559
Two-Stage LFL 72 0.295 0.488
0.569 0.457
80 0.330 0.544
Two-Stage FFL 72 0.300 0.503
J3.20XM 0.533 0.366
80 0.335 0.564
Three-Stage FFL 72 0.300 0.503
0.544 0.396
80 0.335 0.559
LFL = Limited Free Lift FFL = Full Free Lift
*Standard 19 cc (1.16 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm (20 in.)
load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

38
8000 SRM 561 Mast Speeds

190 mm (7.5 in.) Motor and Small Lift Pump*


Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.290 0.411
0.559 0.508
80 0.310 0.462
Two-Stage FFL 72 0.300 0.432
J2.00XM 0.508 0.457
80 0.330 0.478
Three-Stage FFL 72 0.295 0.422
0.528 0.467
80 0.320 0.472
Two-Stage LFL 72 0.274 0.411
0.584 0.508
80 0.295 0.462
Two-Stage FFL 72 0.279 0.432
J2.50XM 0.554 0.457
80 0.305 0.478
Three-Stage FFL 72 0.279 0.422
0.559 0.467
80 0.300 0.472
Two-Stage LFL 72 0.229 0.371
0.559 0.457
80 0.259 0.411
Two-Stage FFL 72 0.234 0.381
J3.00XM 0.523 0.366
80 0.259 0.422
Three-Stage FFL 72 0.234 0.366
0.533 0.396
80 0.259 0.422
Two-Stage LFL 72 0.229 0.371
0.569 0.457
80 0.254 0.411
Two-Stage FFL 72 0.229 0.381
J3.20XM 0.533 0.366
80 0.254 0.422
Three-Stage FFL 72 0.229 0.366
0.544 0.396
80 0.254 0.422
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 12 cc (0.73 in. 3 ) displacement pump, 190 mm (7.5 in.) standard pump motor and 500 mm
(20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

39
Mast Speeds 8000 SRM 561

203 or 190 mm (8.0 or 7.5 in.) Long Stack Motor and Large Lift Pump*
Lifting Lowering
Model Mast V Rated Load No Load Rated Load No Load
m/sec m/sec m/sec m/sec
Two-Stage LFL 72 0.396 0.554
0.569 0.508
80 0.442 0.620
Two-Stage FFL 72 0.406 0.579
J2.00XM 0.523 0.457
80 0.457 0.645
Three-Stage FFL 72 0.401 0.569
0.538 0.467
80 0.452 0.635
Two-Stage LFL 72 0.371 0.554
0.584 0.508
80 0.417 0.620
Two-Stage FFL 72 0.386 0.579
J2.50XM 0.554 0.457
80 0.432 0.645
Three-Stage FFL 72 0.376 0.569
0.559 0.467
80 0.422 0.635
Two-Stage LFL 72 0.320 0.498
0.559 0.457
80 0.361 0.554
Two-Stage FFL 72 0.325 0.513
J3.00XM 0.523 0.366
80 0.366 0.574
Three-Stage FFL 72 0.325 0.508
0.533 0.396
80 0.366 0.569
Two-Stage LFL 72 0.315 0.498
0.569 0.457
80 0.351 0.554
Two-Stage FFL 72 0.320 0.513
J3.20XM 0.533 0.366
80 0.361 0.574
Three-Stage FFL 72 0.320 0.508
0.544 0.396
80 0.356 0.569
LFL = Limited Free Lift FFL = Full Free Lift
*Slow (lift) speed 19 cc (1.16 in. 3 ) displacement pump, GE long stack or BKB 203 mm (8.0 in.) pump
motor and 500 mm (20 in.) load center.
Oil temperature 54 to 66 C (130 to 150 F). Lifting speeds (valve fully open) ±10% acceptable. No Load
lowering speeds are minimum values. Rated Load lowering speeds are maximum values. N/A = Not
Available

40
8000 SRM 561 Torque Specifications

Torque Specifications
FRAME Ring Gear to Differential Case
7/16 UNF × 1 bolts (12)
Overhead Guard - Front Leg M12 × 1.75 × 50 111 N•m (82 lbf ft)
Capscrews (3) Standard Torque Value
Differential Case Halves 3.8 UNF ×
Overhead Guard - Rear Leg M12 × 1.75 × 50 3-1/2 Capscrews (8)
Capscrews (2) Standard Torque Value 50 N•m (37 lbf ft)
Counterweight Capscrews - Upper Bearing Cap Capscrews for Differen-
Capscrews (2) tial Bearings (4)
E2.00-3.20XM (E45-65XM, E45-65XM2) 95 to 110 N•m (70 to 81 lbf ft)
380 N•m (280 lbf ft)
J2.00-3.20XM (J40-65XM, J45-65XM2) Lock Plate Capscrews for Adjusting Nuts (2)
320 N•m (236 lbf ft) 19 N•m (14 lbf ft)

Counterweight Capscrews - Lower (tow pin) Lock Nut for Thrust Screw
M12 × 1.75 × 90 Capscrews (2) 68 to 95 N•m (50 to 70 lbf ft)
66 N•m (49 lbf ft)
Pinion Nut (use shims to set rotating
Counterweight Capscrews - Cover torque with nut tight)
3/8 UNC × 1-1/4 Capscrews (2) 340 N•m (251 lbf ft)
52 N•m (38 lbf ft)
Speed Reducer Housing to Axle (differential)
DRIVE AXLE, SPEED REDUCER, AND Housing E2.00-3.20XM (E45-65XM, E45-65XM 2)
DIFFERENTIAL E.200-3.20XM (E45-65XM, and (N30XMH, N30XMH 2) only
M10 x 1.5 x 30 bolts (6) 38 N•m (28 lbf ft)
E45-65XM 2 AND N30XMH, N30XMH 2) M10 x 1.5 x 40 bolts (2) 38 N•m (28 lbf ft)
Wheel Nuts Traction Motor to Speed Reducer
237 to 305 N•m (175 to 225 lbf ft) M10 x 1.5 x 35 bolts (2) 38 N•m (28 lbf ft)
Wheel Lock Nut M10 x 1.5 x 70 bolts (6) 38 N•m (28 lbf ft)
205 N•m (151 lbf ft) Initial
34 N•m (25 lbf ft) Final DRIVE AXLE, SPEED REDUCER, AND
DIFFERENTIAL J2.00-3.20XM (J40-65XM,
Axle Housing (differential) to Spindle Housing J40-65XM 2)
(axle) M12 × 1.75 × 35 Capscrews (16 each side)
90 N•m (66 lbf ft) Axle Mounts to Frame
Torque Wrench on Head of Bolt 540 N•m
Axle Flange M12 × 1.75 × 35 Capscrews (398 lbf ft)
(16 ea. axle) Torque Wrench on Nut of Bolt 473 N•m (349 lbf ft)
90 N•m (66 lbf ft)
Axle Housing to Differential Housing
Axle Hangers to Frame 38 N•m (28 lbf ft)
Torque wrench on Head of Bolt 780 N•m
(575 lbf ft) Axle Shaft Capscrews
Torque wrench on Nut of Bolt 715 N•m (527 lbf ft) 98 N•m (72 lbf ft)

Back Plate to Axle Mount Capscrews (8) Back Plate to Axle Mount Capscrews
255 N•m (188 lbf ft) 5/8 in. Capscrews 245 N•m (180 lbf ft)
1/2 in. Capscrews 125 N•m (92 lbf ft)
Wheel Cylinder M8 × 1.25 Capscrews
13 to 20 N•m (10 to 15 lbf ft) Bearing Cap Capscrews for Differ-
ential Bearings
95 to 110 N•m (70 to 81 lbf ft)

41
Torque Specifications 8000 SRM 561

Bearing Cap Capscrews for Speed Reducer STEERING AXLE J2.00-3.20XM (J40-65XM,
19 N•m (14 lbf ft) J40-65XM 2)
Differential Case Halves Mount Brackets M12 × 1.75 × 45 bolts (4)
50 N•m (37 lbf ft) 88 N•m (65 lbf ft)
Drive Gear to Differential Case Steering Cylinder to Axle Capscrews
111 N•m (82 lbf ft) M16 × 2 × 50 (8)
225 N•m (166 lbf ft)
Retainer Capscrews for Adjustment Nuts
19 N•m (14 lbf ft) Castle Nut, King Pin (2)
90 N•m (66 lbf ft) Initial
Speed Reducer Housing to Differen-
34 N•m (25 lbf ft) Final
tial Housing
52 N•m (38 lbf ft) Castle Nut, Wheel Hub (2)
Initial 68 N•m (50 lbf ft)
Traction Motor to Speed Reducer Housing
while rotating wheel. Loosen, then
38 N•m (28 lbf ft)
3 N•m (2 lbf ft)
Wheel Cylinder Capscrews
Wheel Nut (20)
7/16 in. Capscrews 78 to 91 N•m (58 to 67 lbf ft)
237 to 305 N•m (174 to 225 lbf ft)
1/2 in. Capscrews 91 to 102 N•m (67 to 75 lbf ft)

Wheel Nuts MASTS


237 to 305 N•m (175 to 225 lbf ft) Capscrews, Hanger Caps
M12 x 1.75 x 100 (4) 90 N•m (66 lbf ft)
STEERING AXLE E2.00-3.20XM (E45-65XM, Mast to Mount Pivot Pins 130 N•m (96 lbf ft)
E45-65XM 2 AND N30XMH, N30XMH 2)
Tilt Rod End M12 × 1.75 × 55 (2)
Mount Brackets M12 × 1.75 × 45 bolts (4) 90 N•m (66 lbf ft)
88 N•m (65 lbf ft)
SEAT BRAKE
Steering Cylinder to Axle Capscrews
M16 × 2 × 130 (4) Lever Arm Pivot at Motor M12 × 1.75 (1)
121 N•m (89 lbf ft) 40 N•m (30 lbf ft)
Tie Rod Nuts 3/4 UNF (2) Brake Drum Mount (to armature shaft)
163 N•m (120 lbf ft) M12 × 1.75 × 50 (1)
66 N•m (49 lbf ft) lubed
Capscrews, Lower Spindle Cap (6) 3/8 UNC × 1
44 N•m (32 lbf ft)

Castle Nut, Wheel Hut (2)


Initial 68 N•m (50 lbf ft)
while rotating wheel. Loosen, then
3 N•m (2 lbf ft)

42
8000 SRM 561 Adhesives and Sealants

Adhesives and Sealants


Hyster Part Loctite®
Description Size
No. Part No.
360387 222 Small Screw Threadlock (Purple) 50 ml (1.7 oz)
318702* 242 Removable Threadlock (Blue) 10 ml (0.34 oz)
226414* 271 High Strength Threadlock (Red) 10 ml (0.34 oz)
318996 277 High Viscosity Threadlock (Red) 50 ml (1.7 oz)
318650 290 Low Viscosity Threadlock (Green) 0.6 ml (0.02 oz)
251099 290 Low Viscosity Threadlock (Green) 50 ml (1.7 oz)
355844* 422 SuperBonder® Adhesive 3 ml (0.1 oz)
350830 515 Gasket Eliminator (Purple) 6 ml (0.2 oz)
313022* 515 Gasket Eliminator (Purple) 50 ml (1.7 oz)
273338* 567 Pipe Sealant with Teflon® (White) 50 ml (1.7 oz)
318705 595 Super Flex® Silicone 100 ml (3.4 oz)
318701 609 Retaining Compound 10 ml (0.34 oz)
341959 680 Retaining Compound 50 ml (1.7 oz)
226415 Primer T - Aerosol 177 ml (6 oz)
316865 Antiseize Compound 476 ml (16 oz)
360053 Chisel Gasket Remover (10 Aerosol cans per case) 536 ml (18 oz)
318700* Adhesive & Sealant Kit (Contains one each of * items)
Loctite®, Super Flex®, and SuperBonder® are registered trademarks of the Loctite Corporation.
Teflon® is a registered trademark of Du Pont de Nemours Co. Inc.

43
NOTES

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

____________________________________________________________

44
TECHNICAL PUBLICATIONS

8000 SRM 561 8/03 (3/99)(3/95)(7/94) Printed in U.S.A.

You might also like