You are on page 1of 6

1.

Product Introduction
DVP02LC-SL ............................................................................................................................. 1
DVP32HM11N............................................................................................................................ 1

2. Electrical and Hardware Specifications ............................................................................ 2


2.1 DVP02LC-SL ....................................................................................................................... 2
2.2 DVP32HM11N...................................................................................................................... 3

3. Ordering information ........................................................................................................... 7

4. Expected Release Date ........................................................................................................ 7

w w w . d e l t a w w . c o m
Product Introduction

I. Product Introduction

DVP02LC-SL

Succeeding to the 16-bit high resolution analog I/O modules,


DVP04AD-SL and DVP04DA-SL, Delta releases DVP02LC-SL
load cell module with high capability of weight measurement
function.
DVP02LC-SL provides 24-bit resolution applicable for 4-wire or
6-wire load cells with various eigenvalues. Therefore, the
response time and the resolution can be adjusted in coordination
with each other according to users’ needs. On this basis, the
market requirements on weight measurement can easily be met.
In addition, aiming at the tension control applications,
DVP02LC-SL is developed to fully support the field applications
which require high accuracy and stability. Currently, the
successful tension control cases are available and will be
provided later.

DVP32HM11N

DVP-EH2 series 32 Digital input module

w w w . d e l t a w w . c o m
Electrical And Hardware Specifications

2. Electrical and Hardware Specifications


2.1 DVP02LC-SL
DVP02LC-SL - Outline

3 mm
DVP02LC
PO W ER
E XC+
R UN
E XC-
ERR O R
S IG +
L.V
C H1 S IG -

S EN+

S EN-

N ET S HD

ZER O

M AX
90 mm
M OTIO N

E XC+

E XC-

S IG +

C H2 S IG -

N ET S EN+

ZER O
S EN-

M AX S HD

M OTIO N

60 mm 33 mm [ Figure 1 ]

1. Mounting hole of the I/O module 7. I/O terminals

2. DIN rail mounting slot (35mm) 8. RS-232 port

3. I/O module connection port 9. Mounting slot clip

4. I/O module clip 10. RS-485 port

Status indicator
5. 11. DC power input
(POWER, RUN, ERROR and L.V)

Function status indicator


6.
(NET, ZERO, MAX, MOTION)

w w w . d e l t a w w . c o m
DVP02LC-SL – Electrical Specification

Load cell module Output voltage range


Power supply voltage 24 VDC (-15% to +20%) / 3W
Power input boundary 18 to 31.2 VDC
Max. current consumption 125 mA
Input signal range ± 40 mVDC
Sensibility +5 VDC +/-10%
Internal resolution 24 bits
Communication port RS-232, RS-485
Sensor type 4-wire or 6-wire strain gauge
Temperature coefficient span ≤ ± 50 ppm/K v. E
Temperature coefficient zero
≤ ± 0.4 µV/K
point
Linearity error ≤ 0.02%
Response time 2, 10, 20, 40, 80 ms × channels
4 measuring ranges 0 to 1 mV/V, 0 to 2 mV/V, 0 to 4 mV/V, 0 to 6mV/V
Max. distance for connecting to
100 M
load cell
Current output 5 VDC * 300 mA (2 channels, max.)
Permitted load cell resistance 40 ~ 4,010 Ω
Common mode rejection
Minimum 100dB
(CMRR @50/60 Hz)
Dynamic value filter Setting range: K1 ~ K5
Average value filter Setting range: K1 ~ K100
500 VAC between digital circuits and Ground
Isolation method 500 VAC between analog circuits and Ground
500 VAC between analog circuits and digital circuits
Connectable to the left side of MPU, numbered from 100 to
Series connection to DVP-PLC
107 according to the position of module from the closest to
MPU
farthest to MPU.
Operation: 0 to 55°C (temp.), 50 to 95% (humidity),
Operation/storage temperature pollution degree 2
Storage: -25 to 70°C (temp.), 5 to 95% (humidity)
International standards: IEC61131-2, IEC 68-2-6 (TEST
Vibration/shock immunity
Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea)

2.2 DVP32HM11N
DVP32HM11N - Outline

w w w . d e l t a w w . c o m
6 9 8 10 6
2 6
7 X2 1
4 .6

90. 0
80 .0 4

3 3
W 11 82.2 [ Figure 2 ]

Model name 32HM11N


W 143.5
H 82.2

1. Power, LV indicators 5. Extension wiring 9. Cover


2. I/O terminals 6. Extension port cover 10. Input indicators
3. DIN rail clip 7. Direct mounting holes 11. Output indicators
4. DIN rail 8. Model name

DVP32HM11N – Electrical Specification

Model
32HM11N
Item
Power supply
24VDC (20.4 ~ 28.8VDC) (-15% ~ 20%)
voltage
Fuse capacity 2A/250VAC
Power
3.9W
consumption
1,500VAC (Primary-secondary), 1,500VAC (Primary-PE),
Voltage withstand
500VAC (Secondary-PE)
Insulation
> 5MΩ at 500VDC (between all I/O points and ground)
resistance
ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O:
Noise immunity
250V
Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m
The diameter of grounding wire shall not be less than that of L, N terminal
Grounding of the power supply. (When many PLCs are in use at the same time,
please make sure every PLC is properly grounded.)
Operation: 0°C~55°C (temperature), 50~95% (humidity), pollution degree
Operation/
2
storage
Storage: -25°C~70°C (temperature), 5~95% (humidity)

w w w . d e l t a w w . c o m
Model
32HM11N
Item
Vibration/shock International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2
immunity & IEC 68-2-27 (TEST Ea)
Weight (g) 355
Approvals

Ordering information

DVP 02 LC - SL

SL:DVP-S left side extension

Load cell module

2 Channels

DVP PLC

DVP 32 HM 11 N
No output

DC power input

EH2 series output mode

32 I/O

DVP PLC

Expect Release Date

Name Model Date MOQ(pcs)

Load cell module DVP02LC-SL 10/6/2010 6

DVP-EH2 32DI module DVP32HM11N 10/6/2010 6

w w w . d e l t a w w . c o m

You might also like