Beam Dimensions

Name h bf tf bw tw
W6x16 159.5 102.4 10.3 138.9 6.6 BEAM
W8x40 209.6 205 14.2 181.2 9.144 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 235613.8 N 32726.756171 minimum flange thickness required by
t_fc 12.99

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 22.2 mm
Pbf 275307.5 N

Web Crippling (AISC-J10.3)


phi 0.75
d 209.6 mm
Pbf 474034.6 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on y
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 600227.4 N
Do we need this value? Yes

Is there a need for stiffeners? No

Design for stiffeners


phi 0.85
Ast,req -188.1402 mm2

stiffener size limitation Use


min bst 29.56133 mm 30 mm bst/ts
min tst 5.15 mm 6 mm 5
Asf 360 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 4.118617
KL/r 38.16815 Fe 1354.963
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 229.8913 MPa


Ag 2450.318 mm2

phi_c*Pn = phi_c*Ag*Fcr 506976.1 N OK


ON REGION WELDING CONNECTION OF PLATES TO COLUMN
phi_t
mum flange thickness required by AISC-J10.1 F_Exx
mm Tension stiffener not required a_max_eff
min weld size (see AISC Table J2.4)
use

Max Force carried by stiffeners


PLATES TO COLUMN
0.9
414 Mpa F60XX
5.088063 mm *must consider shear if beam if on one side of column only
6 mm *edit according to table
6 mm
Beam Dimensions

Name h bf tf bw tw
W8x15 206 102.1 8.001 189.998 6.223
W8x40 209.6 205 14.2 181.2 9.144

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa
beam flange welded to the web of column? Y
T 165.2
ceff 50.90526 mm
Moment Capacity of Web 12835.89 Nm Mapplied 36132.38
Need stiffeners
Pbf 182487.7 N
*only applicable when tee flange width is approximately the same as the beam flange width

1. Tee Local Web Yielding


k (mm) 17.90092 assumption
tee web thickness, tw 5.655151 mm

2. Local flange bending from tension force AISC J-10.1


phi_t 0.9
t_s 9.900922 mm

3. tee flange width, bs


bs 181.2 mm

4. Structural tee depth, ds


ds 97.928 mm
COMPRESSION REGION
Maximum Factored Force
Pbf 182487.7 N

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 22.2 mm
Pbf 270089.6 N

Web Crippling (AISC-J10.3)


phi 0.75
d 209.6 mm
Pbf 466544.9 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on both sides of column? Y

phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 600227.4 N
Do we need this value? Yes

Is there a need for stiffeners? No

Design for stiffeners


phi 0.85
Ast,req -415.2156 mm2

stiffener size limitation Use


min bst 29.46133 mm 30 mm bst/ts
min tst 4.0005 mm 5 mm
Asf 300 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web + stiffeners 3.937792
KL/r 39.92085 Fe 1238.598
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 228.2412 MPa


Ag 2390.318 mm2

phi_c*Pn = phi_c*Ag*Fcr 491012.3 N OK


BEAM
COLUMN

Nm
Need stiffeners
TENSION REGION
phi_t 0.9
minimum flange thickness required by AISC-J10.1
t_fc 11.43 mm Tension stiffener not required

anual for h/tw values


6
WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
F_Exx 414 Mpa F60XX
a_max_eff 4.240053 mm *must consider shear if beam if on one side of column only
min weld size (see AISC Table J2.4) 6 mm *edit according to table
use 6 mm

Max Force carried by stiffeners


on one side of column only
256.5 203.7 15.7 225.1 8.89
Beam Dimensions

Name h bf tf bw tw
W6x16 159.5 102.4 10.3 138.9 6.6 BEAM
W6x25 162.1 154.4 11.6 138.9 8.128 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 235613.8 N minimum flange thickness required by AISC
t_fc 12.99 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 19.6 mm
Pbf 218490.8 N

Web Crippling (AISC-J10.3)


phi 0.75
d 162.1 mm
Pbf 370945.6 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 474253.8 N
Do we need this value? No

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 81.15953 mm2

stiffener size limitation Use


min bst 30.06933 mm 32 mm bst/ts
min tst 5.15 mm 6 mm 5.333333
Asf 384 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 4.534778
KL/r 26.80947 Fe 2746.334
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 238.997 MPa


Ag 2035.61 mm2

phi_c*Pn = phi_c*Ag*Fcr 437854.1 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener required a_max_eff 5.088063
use same stiffener as compression region stiffener min weld size (see AISC Table J2.4) 6
use 6

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W8x31 203.2 203.1 11 181.2 7.239 BEAM
W10x45 256.5 203.7 15.7 225.1 8.89 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 499075.4 N minimum flange thickness required by AISC
t_fc 18.91 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 23.7 mm
Pbf 285754.2 N

Web Crippling (AISC-J10.3)


phi 0.75
d 256.5 mm
Pbf 468335.5 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 567344.6 N
Do we need this value? No

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 1011.1 mm2

stiffener size limitation Use


min bst 63.255 mm 64 mm bst/ts
min tst 5.5 mm 6 mm 10.66667
Asf 768 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 10.01414
KL/r 19.21034 Fe 5348.84
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 243.4366 MPa


Ag 2743.803 mm2

phi_c*Pn = phi_c*Ag*Fcr 601147.7 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener required a_max_eff 5.088063
use same stiffener as compression region stiffener min weld size (see AISC Table J2.4) 6
use 6

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W6x16 159.5 102.4 10.3 138.9 6.6 BEAM
W10x45 256.5 203.7 15.7 225.1 8.89 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 235613.8 N minimum flange thickness required by AISC
t_fc 12.99 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 23.7 mm
Pbf 284209.5 N

Web Crippling (AISC-J10.3)


phi 0.75
d 256.5 mm
Pbf 466786.7 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 567344.6 N
Do we need this value? No

Is there a need for stiffeners? No

Design for stiffeners


phi 0.85
Ast,req -230.3341 mm2

stiffener size limitation Use


min bst 29.68833 mm 30 mm bst/ts
min tst 5.15 mm 6 mm 5
Asf 360 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 4.138859
KL/r 46.4802 Fe 913.6791
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 221.5338 MPa


Ag 2335.803 mm2

phi_c*Pn = phi_c*Ag*Fcr 465713.4 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener not required a_max_eff 5.088063
min weld size (see AISC Table J2.4) 6
use 6

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W8x31 203.2 203.1 11 181.2 7.239
W10x45 256.5 203.7 15.7 225.1 8.89

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa
beam flange welded to the web of column? Y
T 209.1
ceff 56.88967 mm
Moment Capacity of Web 11318.84 Nm Mapplied 95922.29
Need stiffeners
Pbf 499075.4 N
*only applicable when tee flange width is approximately the same as the beam flange width

1. Tee Local Web Yielding


k (mm) 24.37352 assumption
tee web thickness, tw 11.34978 mm

2. Local flange bending from tension force AISC J-10.1


phi_t 0.9
t_s 16.37352 mm

3. tee flange width, bs


bs 225.1 mm

4. Structural tee depth, ds


ds 97.405 mm
COMPRESSION REGION
Maximum Factored Force
Pbf 499075.4 N

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 23.7 mm
Pbf 285754.2 N

Web Crippling (AISC-J10.3)


phi 0.75
d 256.5 mm
Pbf 468335.5 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on both sides of column? Y

phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 567344.6 N
Do we need this value? Yes

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 1011.1 mm2

stiffener size limitation Use


min bst 63.255 mm 64 mm bst/ts
min tst 5.5 mm 6 mm
Asf 768 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web + stiffeners 10.01414
KL/r 19.21034 Fe 5348.84
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 243.4366 MPa


Ag 2743.803 mm2

phi_c*Pn = phi_c*Ag*Fcr 601147.7 N OK


BEAM
COLUMN

Nm
Need stiffeners
TENSION REGION
phi_t 0.9
minimum flange thickness required by AISC-J10.1
t_fc 18.91 mm Tension stiffener required
use same stiffener as compression region stiffener

anual for h/tw values


10.66667
WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
F_Exx 414 Mpa F60XX
a_max_eff 5.088063 mm *must consider shear if beam if on one side of column only
min weld size (see AISC Table J2.4) 6 mm *edit according to table
use 6 mm

Max Force carried by stiffeners


on one side of column only
Beam Dimensions

Name h bf tf bw tw
W8x31 203.2 203.1 11 181.2 7.239 BEAM
W8x31 203.2 203.1 11 181.2 7.239 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 499075.4 N minimum flange thickness required by AISC
t_fc 18.91 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 19 mm
Pbf 190460.7 N

Web Crippling (AISC-J10.3)


phi 0.75
d 203.2 mm
Pbf 296756.8 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 376184.2 N
Do we need this value? No

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 1462.772 mm2

stiffener size limitation Use


min bst 64.0805 mm 66 mm bst/ts
min tst 5.5 mm 8 mm 8.25
Asf 1056 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 12.82294
KL/r 11.88495 Fe 13974.46
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 246.3726 MPa


Ag 2366.078 mm2

phi_c*Pn = phi_c*Ag*Fcr 524643.1 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener required a_max_eff 6.784085
use same stiffener as compression region stiffener min weld size (see AISC Table J2.4) 6
use 6.784085

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W6x16 159.5 102.4 10.3 138.9 6.6 BEAM
W8x31 203.2 203.1 11 181.2 7.239 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 235613.8 N minimum flange thickness required by AISC
t_fc 12.99 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 19 mm
Pbf 189203 N

Web Crippling (AISC-J10.3)


phi 0.75
d 203.2 mm
Pbf 295250.1 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 376184.2 N
Do we need this value? No

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 219.978 mm2

stiffener size limitation Use


min bst 30.51383 mm 32 mm bst/ts
min tst 5.15 mm 6 mm 5.333333
Asf 384 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 4.766523
KL/r 31.97299 Fe 1930.915
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 235.2094 MPa


Ag 1694.078 mm2

phi_c*Pn = phi_c*Ag*Fcr 358616.8 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener required a_max_eff 5.088063
use same stiffener as compression region stiffener min weld size (see AISC Table J2.4) 6
use 6

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W4x13 105.7 103.1 8.763 88.174 7.112 BEAM
W6x16 159.5 102.4 10.3 138.9 6.6 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 201825 N minimum flange thickness required by AISC
t_fc 12.02 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 18.3 mm
Pbf 164250.1 N

Web Crippling (AISC-J10.3)


phi 0.75
d 159.5 mm
Pbf 249492.6 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 312702.4 N
Do we need this value? No

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 178.0976 mm2

stiffener size limitation Use


min bst 31.06667 mm 32 mm bst/ts
min tst 4.3815 mm 5 mm 6.4
Asf 320 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 4.710176
KL/r 25.39714 Fe 3060.273
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 239.9263 MPa


Ag 1409 mm2

phi_c*Pn = phi_c*Ag*Fcr 304250.5 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener required a_max_eff 4.240053
use same stiffener as compression region stiffener min weld size (see AISC Table J2.4) 6
use 6

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W8x31 203.2 203.1 11 181.2 7.239 BEAM
W6x16 159.5 102.4 10.3 138.9 6.6 COLUMN

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa

COMPRESSION REGION TENSION REGION


Maximum Factored Force phi_t 0.9
Pbf 499075.4 N minimum flange thickness required by AISC
t_fc 18.91 mm

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 18.3 mm
Pbf 167914.7 N

Web Crippling (AISC-J10.3)


phi 0.75
d 159.5 mm
Pbf 254457.4 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on n
both sides of column?
phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 312702.4 N
Do we need this value? No

Is there a need for stiffeners? Yes

Design for stiffeners


phi 0.85
Ast,req 1569.635 mm2

stiffener size limitation Use


min bst 64.4 mm 66 mm bst/ts
min tst 5.5 mm 10 mm 6.6
Asf 1320 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web +
stiffeners 14.16139
KL/r 8.447262 Fe 27662.91
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 247.2806 MPa


Ag 2409 mm2

phi_c*Pn = phi_c*Ag*Fcr 536129 N OK


WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
thickness required by AISC-J10.1 F_Exx 414
Tension stiffener required a_max_eff 8.480106
use same stiffener as compression region stiffener min weld size (see AISC Table J2.4) 6
use 8.480106

Max Force carried by stiffeners


Mpa F60XX
mm *must consider shear if beam if on one side of column only
mm *edit according to table
mm
Beam Dimensions

Name h bf tf bw tw
W6x16 159.5 102.4 10.3 138.9 6.6
W8x31 203.2 203.1 11 181.2 7.239

phi 0.9
Fy 248.211 MPa
fillet width 8 mm
E 200000 MPa
beam flange welded to the web of column? Y
T 165.2
ceff 25.63871 mm
Moment Capacity of Web 5451.988 Nm Mapplied 35153.58
Need stiffeners
Pbf 235613.8 N
*only applicable when tee flange width is approximately the same as the beam flange width

1. Tee Local Web Yielding


k (mm) 19.25017 assumption
tee web thickness, tw 6.681654 mm

2. Local flange bending from tension force AISC J-10.1


phi_t 0.9
t_s 11.25017 mm

3. tee flange width, bs


bs 181.2 mm

4. Structural tee depth, ds


ds 97.9305 mm
COMPRESSION REGION
Maximum Factored Force
Pbf 235613.8 N

Does the connection need stiifeners?

Local Web Yielding (AISC-J10.2)


phi 1
k 19 mm
Pbf 189203 N

Web Crippling (AISC-J10.3)


phi 0.75
d 203.2 mm
Pbf 295250.1 N

Compression Buckling of Web (AIS-J10.5)


Are there two beams on both sides of column? Y

phi 0.9
h/tw 21.2 see AISC Steel Construction Manual for h/tw values
Pbf 376184.2 N
Do we need this value? Yes

Is there a need for stiffeners? No

Design for stiffeners


phi 0.85
Ast,req 219.978 mm2

stiffener size limitation Use


min bst 30.51383 mm 32 mm bst/ts
min tst 5.15 mm 6 mm
Asf 384 mm2 >Ast,req

local buckling limits


when elastic analysis is used
max bst/ts 15.89617
when plastic analysis is used
max bst/ts 10.78669

column strength of stiffeners


phi_c 0.9
K 0.75 *need to find out why 0.75
radius of gyration, web + stiffeners 4.766523
KL/r 31.97299 Fe 1930.915
AISC-E3
4.71sqrt(E/Fy) 133.6981 0.44Fy 109.2128

Fcr 235.2094 MPa


Ag 1694.078 mm2

phi_c*Pn = phi_c*Ag*Fcr 358616.8 N OK


BEAM
COLUMN

Nm
Need stiffeners
TENSION REGION
phi_t 0.9
minimum flange thickness required by AISC-J10.1
t_fc 12.99 mm Tension stiffener required
use same stiffener as compression region stiffener

anual for h/tw values


5.333333
WELDING CONNECTION OF PLATES TO COLUMN
phi_t 0.9
F_Exx 414 Mpa F60XX
a_max_eff 5.088063 mm *must consider shear if beam if on one side of column only
min weld size (see AISC Table J2.4) 6 mm *edit according to table
use 6 mm

Max Force carried by stiffeners


on one side of column only