RESULT:

Table 1:

Values and Percentage Reduction in Displacement of two-storey Base Isolated Building

VALUES OF DISPLACEMENT (m) PERCENTAGE REDUCTION (%) IN


FIXED FPS DISPLACEMENT
0.458 0.194 FIXED FPS
0 56.5

As we can see from the result, a fixed base structure's storey drift is 9.4x10 ¯³ more than friction
pendulum-based structure. Time is directly proportional to the building's storey drift, where values have
shown that a base isolated structure is rising gradually in drifting compared to a fixed base structure.
Therefore, under the operation of lateral forces base isolated structure is safer.

Table 2:

Values and Percentage Reduction in Acceleration of two-storey Base Isolated Building

VALUES OF ACCELERATION (m/s²) PERCENTAGE REDUCTION (%) IN


ACCELERATION
FIXED FPS FIXED FPS
4.866 1.427 0 71.7

The acceleration of the base isolated structure decreases as compared with the fixed based structure.
From the results obtained, the acceleration of the isolated structure of the friction pendulum base
decreases by 3.439m / s^2 relative to a fixed structure. As the time period increases, the acceleration of
the base isolated structure decreases by 1,023m / s² relative to the fixed base structure with constant
acceleration.

Table 3:

Values and Percentage Reduction in Displacement of two-storey Base Isolated Building

VALUES OF STOREY DRIFT (m) PERCENTAGE REDUCTION (%) IN


FIXED FPS STOREY DRIFT
0.0111 0.0017 FIXED FPS
0 83.4

Based on the results obtained, the displacement of the structure with friction pendulum system is
shown to decrease by 0.264 m as compared to the fixed structure. Time period is also shown to be
inversely proportional to displacement. With respect to time period, the displacement decreases.
Table 4:

Values and Percentage Reduction in Displacement of two storey Base Isolated Building

VALUES OF TIME PERIOD (s) PERCENTAGE REDUCTION (%) IN


FIXED FPS TIME PERIOD
2.811 4.605 FIXED FPS
0 38.0

STOREY
5 HEIGHT v/s TIME
PER
4 IOD
TIME PERIOD, (S)

3
FIXED FPS
2
1
0
2-Storey
Building
STOREY HEIGHT

As the time period of Friction Pendulum Base isolated structure increases by 1.794 seconds, the
structural damage during ground shaking decreases as compared to the Fixed structure with a time
period of 2.811 sec. Other parameters such as displacement, acceleration, and storey drift have been
observed to decrease with increasing time period.

REFERENCE:

https://www.academia.edu/33478233/SEISMIC_PERFORMANCE_AND_ECONOMIC_FEASIBILITY_OF_STR
UCTURES_BY_OPTIMAL_POSITIONING_OF_COMBINED_BASE_ISOLATION_SYSTEMS