OPERATING INSTRUCTIONS C.A.T.

UNIVERSAL
Step 1. (Fig. 1) With the tool in the open position NOTE: PRIOR TO OPERATING TOOL
(tool handle on the bottom), place the cable and Prepare cable to SCTE specifications. Refer to
Compression Assembly Tool
connector into the tool opening over the plunger Cablematic SDT, UDT or DDT tool for proper
tip. Apply a downward pressure on the cable and cable preparations. Assemble connector to
connector to allow the split jaws to secure the prepared cable end per connector Warning! This tool should not be used on
cable. The cable and connector will now be in manufacturer’s instructions. live electrical circuits. It is not protected
position between the plunger tip and the split jaws. against electrical shock! Always use
Step 2. (Fig. 2) To compress the connector, close 59 & 6 Series
Assembly Tool Ordering Guide OSHA/ANSI or other industry approved eye
the tool handle completely, insuring the connector Model Connector/Manufacturer
Plunger Tip protection when using tools. This tool is not
Color Code
sleeve is fully compressed. C.A.T.-EX Express / PPC Black to be used for purposes other than intended.
Step 3. (Fig. 3) To remove the cable assembly, TRS / PCT Read carefully and understand instructions
open the tool and press the outside split-jaw tabs C.A.T.-EZF EZF / Raychem 59/Blue, 6/Red
EX-XL and CMP / PPC
before using this tool.
C.A.T.-UNIVERSAL
and pull out the connector assembly. Ultra Ease, Ultra Range / Gilbert Green
C.A.T.-UNIVERSAL FX* Snap N Seal / T&B
Digicon S & T / Arris
Compression Adjustment DRS / PCT CX3 / Cabelcon
Cablematic Tools are manufactured with the finest C.A.T.-SPL SPL / Stirling Gray
C.A.T.-TAC TAC / Gilbert Yellow
materials available. However, to overcome normal * Non-Adjustable
wear and tear and ensure tool life, a compression
adjustment feature has been added. Also, a gage Plunger Tip Replacement Kit
Plunger Tip
Model Connector/Manufacturer
block is supplied with the tool to check for the proper Kit Model No.
C.A.T.-EX Express / PPC PT-EX
setting of the plunger adjustment. TRS / PCT
C.A.T.-EZF EZF / Raychem PT-EZF
EX-XL and CMP / PPC
C.A.T.-UNIVERSAL
To check the compression, place the gage block Ultra Ease, Ultra Range / Gilbert PT-UNIVERSAL
Snap N Seal / T&B
between the plunger tip and split jaws. Close the Digicon S & T / Arris
tool completely. The gage block should fit securely DRS / PCT CX3 / Cabelcon
C.A.T.-SPL SPL / Stirling PT-SPL
between the plunger tip and the split jaws. C.A.T.-TAC TAC / Gilbert PT-TAC

Gage Block Replacements


Fig. 4 If adjustments are necessary, close the tool Gage Block
Model Connector/Manufacturer Model No. US PATENT No. 5,934,137
and position the gage block between the plunger and C.A.T.-EX Express / PPC GB-EX
split jaws. Then loosen set screw “A” 1/2 of a turn. TRS / PCT
C.A.T.-EZF EZF / Raychem GB-EZF
Place the hex wrench through the top of the gage C.A.T.-UNIVERSAL
EX-XL and CMP / PPC Thank you for choosing Cablematic®
Ultra Ease,Ultra Range / Gilbert GB-UNIVERSAL
block to engage the hex screw in the plunger. Snap N Seal / T&B brand Tools.
Tighten and /or loosen the plunger tip so that the Digicon S & T / Arris
DRS / PCT CX3 / Cabelcon
gage block fits securely between the plunger and C.A.T.-SPL SPL / Stirling GB-SPL

split-jaws. Then retighten set screw “A”. C.A.T.-TAC TAC / Gilbert GB-TAC We believe you have selected the best.

Plunger Tip Change Over


Plunger tips are color coded for identification.
To change over the plunger tip, first remove set
screw “A” by turning it counter-clockwise with the
WARRANTY: The Ripley Company warrants that our line
hex wrench provided. Next, place the hex wrench of tools are free of defect and fully operable at the time of
through the split jaws engaging the hex screw in the shipment. The warranty is limited to the repair or
plunger tip. Remove the plunger tip by turning it replacement of any product which proves to be defective in
counter-clockwise. Replace with the desired color material or workmanship, under
coded plunger tip, and tighten by turning it normal use and service.
clockwise. Once the plunger tip is installed, replace
set screw “A”. DO NOT OVER TIGHTEN, be
46 Nooks Hill Road
sure to check the compression adjustment as stated Cromwell, CT 06416
above the with the gage block. Phone: 800-528-8665
Int’l: (01) 860-635-2200
Lubrication Fax: (01) 860-635-3631
Proper lubrication of this tool is very important. Lack e-mail: info@ripley-tools.com
of lubrication can greatly reduce the life of the tool. A
Internet: www.ripley-tools.com
“3 in 1” oil should be applied at regular intervals to all
exposed pins, pivot points and moving parts. 37322 rev1
11-02-11 ff