IOM1/2-IOM3 Migration Procedure
GPEC IP TEAM
Introduction .............................................................................................................. 4
General ............................................................................................................ 4
Purpose ........................................................................................................... 4
Intended Audience ............................................................................................. 4
Document Conventions ........................................................................................ 4
Document Revision History .................................................................................... 4
Web Site .......................................................................................................... 4
IP-GPEC Announcements ...................................................................................... 4
Feedback ......................................................................................................... 4
Document Issues ................................................................................................ 5
Timeline .......................................................................................................... 5
References ........................................................................................................ 6
Reference List ................................................................................................... 6
Requirements ..................................................................................................... 7
Pre-requisites ................................................................................................... 7
Engineering Skills ............................................................................................... 7
Required Materials ............................................................................................. 7
Pre-Migration ............................................................................................................ 8
Pre-Migration Tasks.............................................................................................. 8
Configuring the Chassis Mode ................................................................................. 8
Console Connection ............................................................................................ 8
Pre-Checks ....................................................................................................... 9
Tech-support File .............................................................................................. 10
Save Log File.................................................................................................... 11
Required Outputs .............................................................................................. 12
Backup Configuration ......................................................................................... 12
File ............................................................................................................... 12
Migration ................................................................................................................ 13
Migration Tasks .................................................................................................. 13
Saving the Configuration File ................................................................................ 13
Find Card Configuration ...................................................................................... 13
Modify Card Configuration ................................................................................... 14
Remove the Card on SAM ..................................................................................... 15
IOM2-IOM3 Replacement ....................................................................................... 16
Replace the Cards ............................................................................................. 16
Install the MDA ................................................................................................. 16
Check Card Status ............................................................................................. 16
Exec the Configuration File .................................................................................. 17
‘Card Status’ after exec command ......................................................................... 17
Post-Migration .......................................................................................................... 18
Post-Migration Tasks ........................................................................................... 18
Post-Checks ..................................................................................................... 18
Required Outputs .............................................................................................. 18
Tech-support File .............................................................................................. 19
Synchronize CPM Cards ....................................................................................... 19
Verify the synchronization ................................................................................... 20
Equipment Check on 5620 SAM .............................................................................. 21
Re-synch with 5620 SAM ...................................................................................... 21
Back out ................................................................................................................. 22
Back out Tasks................................................................................................... 22
Introduction .................................................................................................... 22
Actions ........................................................................................................... 22
Appendix-A: Additional Information ................................................................................ 23
Console Cable ................................................................................................... 23
Introduction .................................................................................................... 23
Pin-out Configuration ......................................................................................... 23
7750 SR & 7450 ESS R10.0 IOM2-IOM3 Migration Procedure 3FQ 24026 30XF PGZZA
Introduction
General
Purpose The purpose of this document is to provide the procedure to upgrade existing IOM1/2s to
IOM-3 modules. This procedure provides minimal service disruption without reboot.
Intended This document is intended for internal use only and shall be distributed among the people
Audience listed below.
Integration Engineers
Field Engineers
Technical Project Managers
Project Managers
Document Yellow highlighted text depends on the network configuration and can be different in your
Conventions setup.
Document The below table shows the revision history of this document.
Revision History
NOTE: Please check IP-GPEC Homepage for the most recent version of this document.
Web Site You can visit the following page for other IPD product documents.
https://all1.na.alcatel-lucent.com/Teams/GCDNetworks/IPGPEC/default.aspx
IP-GPEC In order to be kept updated with the most recent news from IP GPEC Team, please join the
Announcements engage group using the link below.
https://engage.alcatel-lucent.com/groups/ipd-gpec
General, Continued
Document If you find any issues about this document, please raise a ticket for NPIf-IPD-TR Workgroup.
Issues Simply, send email to support@alcatel-lucent.com including:
Cares Workgroup
Your contact information
Document Name
Issue Description
Timeline
The table below summarizes the expected time.
References
Reference List You can find the list of references referred in this document in the table below:
No Title
1 7750 SR-12
INSTALLATION GUIDE
93-0019-08-12
2 BEST PRACTICES FOR USING COMPACT FLASH ON A 7X50
Version 1.0
3 7750 SR
BASIC SYSTEM CONFIGURATION GUIDE
93-0070-09-02
Requirements
Pre-requisites
Engineering Person who is in charge of performing procedures explained in this document should be
Skills capable of;
7750 SR software boot process and cards:
- IOM, IMM, MDA, CPM, Compact Flash
Experience of 7750 SR hardware and software installation:
- Knowledge of card installation, checking 7750 SR logs
Experience of 5620 SAM
Pre-Migration
Pre-Migration Tasks
Configuring the Make sure that the chassis-mode is compatible with existing and migrated IOMs on the node.
Chassis Mode To check the chassis mode of the system, simply run the command below:
A:IP-GPEC# show chassis
========================================================================
Chassis Information
========================================================================
Name : SR12-1
Type : 7750 SR-12
. . . >>>Output Omitted
Admin chassis mode : b
Oper chassis mode : b
. . . >>>Output Omitted
Depending on the chassis and IOM type, the following modes can be configured;
Console Connect the PC and 7x50 with a console cable, run the terminal software and select the
Connection appropriate serial COM port as below.
NOTE: COM port number may vary on each PC. In the example above , it is COM2.
Pre-Checks
Step Action
1 Run the below commands:
the repair command returns check if there is any file (image, config, etc...) missing
with errors on the failing cf3 card.
the message still doesn‟t there may be no enough space;
appear You should delete unnecessary files in cf3.
the flash cards need to be refer to the following document Reference [2]
replaced
Pre-Checks
(continued)
Step Action
3 Verify the synchronization between active and standby CPM.
If standby status fails for a redundant system, go back to Step 1.
Save Log File The output of each command should be saved to a log file in order to refer back to the status of
the device before reboot.
For SecureCRT, Click Options->Session Options->Log File;
Backup Create a backup directory and backup the configuration under this directory:
Configuration
A:IP-GPEC# file md backup
File
A:IP-GPEC# file copy cf3:\config.cfg cf3:\backup\config.cfg
Copying file cf3:\config.cfg ... OK
1 file copied.
Migration
Migration Tasks
==========================================================================
Remove the If the system is managed by 5620 SAM, IOM1/2 card remove operation on 5620 SAM is
Card on SAM recommended to prevent any possible database corruption.
Click on „Equipment window‟ and select the node and related card slot which will be migrated,
right click and “Remove Card”.
WARNING: Removing card from 5620 SAM will cause service disruption.
This operation deletes the card from the slot therefore the slot and all configuration contained
in the slot is changed to administratively down.
Click on “Yes”.
IOM2-IOM3 Replacement
Replace the Replace the IOM1/2 cards with IOM3 cards as described in Reference [1] in „Installing IOMs,
Cards MDAs and IMMs‟ chapter.
Install the MDA Press the MDA firmly into the slot. Make sure that the connectors are fully seated in the
IOM slot.
Check Card Check card status before executing the new config. The card state will be “Unprovisioned”
Status and equipped card type will be “iom3-xp” as follows:
Exec the
Configuration
WARNING: Depending on the IOM/MDA and configuration, the executing process
File
may take 5-20 minutes.
A:IP-GPEC# exec cf3:\migration.cfg
The current configuration is saved to the primary configuration file with the following command
on the cf3 card.
A:IP-GPEC# admin save
‘Card Status’ Ensure that the IOM3 card state is operational “UP”.
after exec
A:IP-GPEC# show card
command
==========================================================================
Card Summary
==========================================================================
Slot Provisioned Equipped Admin Operational
Comments
Card-type Card-type State State
--------------------------------------------------------------------------
2 iom3-xp iom3-xp up Up
4 iom-20g-b iom-20g-b up up
8 iom-20g-b iom-20g-b up up
A sfm2-200g sfm2-200g up up/active
B sfm2-200g sfm2-200g up up/standby
==========================================================================
Post-Migration
Post-Migration Tasks
Post-Checks Saved logs during the Pre-Migration step indicate the status of the services before migration. In
order to validate the status of the services after migration and verify stability of same services,
before and after Post-Migration tasks should be performed.
Verify the For redundant systems, verify the synchronization between active and standby CPM.
synchronization
A:IP-GPEC# show redundancy synchronization
========================================================================
Synchronization Information
========================================================================
Standby Status : standby ready
Last Standby Failure : N/A
Standby Up Time : 2012/08/04 15:47:43
Standby Version : TiMOS-C-9.0.R11 cpm/hops ALCATEL SR 7750
Copyright (c) 2000-2012 Alcatel-Lucent.
All rights reserved. All use subject to
applicable license agreements.
Built on Fri Feb 17 16:16:25 PST 2012 by
builder in /rel9.0/b1/R11/panos/main
Failover Time : N/A
Failover Reason : N/A
Boot/Config Sync Mode : Configuration
Boot/Config Sync Status : Config only synchronized
Last Config File Sync Time : 08/13/2012 02:00:14
Last Boot Env Sync Time : Never
Rollback Sync Mode : None
Rollback Sync Status : No Rollback synchronization
Last Rollback Sync Time : Never
========================================================================
Equipment If the system is managed by 5620 SAM, check equipment view on 5620 SAM GUI about the
Check on 5620 related chassis and verify that IOM3 is successfully discovered by 5620 SAM:
SAM
Re-synch with Resynchronize the system with 5620 SAM as shown below. Skip if the system is not managed
5620 SAM by 5620 SAM.
Back out
Introduction In order to back out system to initial status, back out operation must be performed.
Step Action
1 Replace the IOM3 card with IOM2 card.
2 Copy the original configuration file to the primary-config file:
A:IP-GPEC# file copy cf3:\backup\config.cfg cf3:\config.cfg
3 If the standby card exists, perform the following command. Otherwise skip to
the next step.
A:IP-GPEC# admin redundancy synchronize boot-env
Console Cable
Introduction In order to connect to the 7x50 products, use a console cable (DB9-DB9). Pin-out table and
figure are as below.
Pin-out
Configuration
- End Of Document –
www.alcatel-lucent.com
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of
Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent
assumes no responsibility for inaccuracies contained herein. Copyright © 2012
Alcatel-Lucent.
All rights reserved.