Professional Documents
Culture Documents
BANDPASS FILTERS
Bandpass and low pass filters are applied between the out- The filter tuning (pass band and stop band insertion loss,
put of a broadcast transmitter and the antenna to suppress matching and variation of group delay time) is fixed in a
spurious emissions. tuning specification (e.g. AS6121).
For analogue “combined” transmitters the filters must It is mandatory to specify in every order this tuning specifi-
suppress the harmonics of vision and sound carrier. cation together with the frequency to assure that the filter is
For DTV transmitters the filters are used to limit the out-of- tuned in the factory as agreed.
Bandpass Filters
channel emissions according to the various mask specifica-
Bandpassfilter
tions (ATSC, DAB, DVB-T and ISDB-T). All bandpass filters can be integrated into multi-channel
combiners where they simultaneously provide the isola-
SPINNER offers coaxial filters, dual-mode wave guide filters, tion between transmitters and mask filtering (please see the
dielectric filters and low pass filters for the frequency ranges chapter multi-channel combiners).
band 3, UHF and band L for the following applications:
The „Environmental Conditions for Broadcast Products“
8 MHz DVB-T and DVB-T2 extended listed in the annex must be obeyed during operation, trans-
port and storage.
8 MHz analog TV The maximum rating of the filter depends on the environ-
mental conditions like temperature, cooling and height
7 MHz DVB-T and DVB-T2 above sea level. The majority of filters can be operated up
to 2300 m above sea level with the power specified in the
7 MHz analog TV data sheet. For stations at higher altitude the power has to
be reduced as shown in the „Environmental Conditions for
6 MHz DVB-T, DVB-T2, ISDB-T and ATSC Broadcast Products”.
For some filters with liquid cooling the derating has to be
6 MHz analogue TV applied above 500 m as shown in the data sheets.
The input and output ports of all bandpass filters end inside
1.54 MHz DAB and T-DMB the resonators with an open or a short. So these filters block
DC and low frequencies.
In the catalog you can find filter data for the most common
applications. However, alternative filter tunings can be made Most bandpass filters are equipped with cross couplings
for other mask requirements, applications and bandwidths. to achieve steeper slopes for mask filtering. Inside multi-
Please do not hesitate to contact us. channel combiners the cross couplings are used to enable
adjacent channels operation.
Part number Frequency in MHz Average input power Typ. application Number / Size of cavities
Bandpass Filters
Bandpassfilter
BN 61 64 09 470 - 860 ≤ 11.2 kW ≤ 14 kW ATV 4/200
Part number Frequency in MHz Average input power Typ. application Number / Size of cavities
BN 61 65 11 1452 - 1468
≤ 1.2 kW DAB / T-DMB 4/DM
BN 61 65 12 1468 - 1492
BN 61 65 13 1452 - 1468
≤ 1.6 kW DAB / T-DMB 4/DM
BN 61 65 14 1468 - 1492
Part number Frequency in MHz Average input power Typ. application Number / Size of cavities
Part number Frequency in MHz Average input power Typ. application Design
ANNEX
-100 1 -100 1
Centre: 201.5000 MHz Span: 24.0000 MHz Centre: 191.5000 MHz Span: 24.0000 MHz
Part number BN 61 63 65 BN 61 63 64
Connectors 7-16 female 1 5/8" EIA
Frequency range 167 - 254 MHz
Number / Size of cavities 4 / 150
Mask filtering ATV ATV
Average input power ≤ 2.7 kW 3.5/0.35 kW BN 61 63 65 ≤ 2.7 kW 3.5/0.35 kW BN 61 63 65
≤ 7.1 kW 10.0/1.0 kW BN 61 63 64 ≤ 7.1 kW 10.0/1.0 kW BN 61 63 64
Tuning instruction Standard D: AS4027 Standard M: AS4013
Standard I: AS4019 Standard B: AS4010
Insertion loss & f(V) - 6 > 30.0 dB f(V) - 6 > 30.0 dB
Mask filtering f(V) - 0.75 MHz ≤ 0.20 dB f(V) - 0.75 MHz ≤ 0.25 dB
(alternative tuning on request) f(V) ≤ 0.20 dB f(V) ≤ 0.25 dB
f(S)= f(V) + 6 ≤ 0.20 dB f(S)= f(V) + 6 ≤ 0.25 dB
f(V) + 26 > 30.0 dB f(V) + 26 > 30.0 dB
VSWR (pass band range) f(V) - 0.75 MHz ≤ 1.15 f(V) - 0.75 MHz ≤ 1.15
f(V) ≤ 1.10 f(V) ≤ 1.10
f(S)= f(V) + 6 ≤ 1.10 f(S)= f(V) + 6 ≤ 1.10
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
BN 61 71 15 C1015 BN 61 71 16 C1025
-60 8 1.16 8
-60 1.16
7 7
-70 13-11 1.12 -70 13-11 1.12
12-11 12-11
-80 1.08 -80 1.08
-100 1 -100 1
Centre: 240.0000 MHz Span: 6.0000 MHz Centre: 240.0000 MHz Span: 6.0000 MHz
Part number BN 61 71 71 BN 61 71 44 BN 61 71 45
Filter design without cross coupling with cross coupling with cross coupling
Frequency range 170 - 240 MHz 215 - 240 MHz
Number / Size of cavities 6 / 150
Harmonics attenuation ≥ 50 dB for f ≤ 500 MHz
Mask filtering DAB / T-DMB @1.54 MHz
(Û/Urms = 13 dB)
Bandpass Filters
installation standing
Bandpassfilter
typical value
dB S11 S21 2-1 1 3-1 VSWR
0 1.4
-20 1.32
-30 1.28
-40 1.24
-50 1.2
-80 1.08
-90 1.04
-100 1
Centre: 223.9360 MHz Span: 6.0000 MHz
Part number BN 61 71 83
typcal value
dB 2-1 1 3-1 VSWR
S11 S21
0 4-1 5-1 1.4
-30 1.28
-40 1.24
-60 1.16
11-1
-7010-1 1.12
-100 1
Centre: 213.0080 MHz Span: 6.0000 MHz
Part number BN 61 71 11 BN 61 71 10
Cooling natural cooling liquid cooling
Frequency range 170 - 240 MHz
Number / Size of cavities 6 / 200
Harmonics attenuation ≥ 50 dB for f ≤ 500 MHz
Mask filtering DAB / T-DMB @1.54 MHz
(Û/Urms = 13 dB)
Bandpass Filters
installation standing
Bandpassfilter
natural or liquid cooling
-100 1 -100 1
Centre: 240.000 MHz Span: 6.000 MHz Centre: 240.000 MHz Span: 6.000 MHz
Part number BN 61 71 08 BN 61 71 09
Cooling natural cooling liquid cooling
Frequency range 170 - 240 MHz
Number / Size of cavities 6 / 200
Harmonics attenuation ≥ 50 dB for f ≤ 500 MHz
Mask filtering DAB / T-DMB @1.54 MHz
(Û/Urms = 13 dB)
-100 1 -100 1
Centre: 240.0000 MHz Span: 6.0000 MHz Centre: 229.072 MHz Span: 6.000 MHz
Part number BN 61 71 13 BN 61 71 12
Cooling natural cooling liquid cooling
Frequency range 170 - 240 MHz
Number / Size of cavities 8 / 200
Harmonics attenuation ≥ 50 dB for f ≤ 500 MHz
Mask filtering DAB / T-DMB @1.54 MHz
(Û/Urms = 13 dB)
Bandpass Filters
installation standing
Bandpassfilter
typical value typical value typical value
dB 2 1 3 VSWR dB 42 1 35 VSWR dB 42 1 35 VSWR
S21 S11 4
S11 S21 6
S21 S11
5 7 6 7
0 1.4 0 1.4 0 1.4
8 9
-10 1.36 -10 1.36 -10 1.36
7 8 9
6 10
-20 1.32 -20 1.32 -20 11 1.32
-60 1.16 14
-60 1.16 -60 1.16
10
12
10 15
-70 1.12 -70 13 1.12 -70 1.12
11 17
-80 1.08 -80 1.08 -80 1.08
16
-90 1.04 -90 1.04 -90 1.04
-100 1 -100 1
Centre: 203.0000 MHz Span: 24.0000 MHz Centre: 230.0000 MHz Span: 24.0000 MHz
Bandpass Filters
installation standing
Bandpassfilter
typical value typical value
dB 2-1 1 3-1 VSWR dB 2-1 1 3-1 VSWR
S21 S11 S11 S21
0 1.4 0 1.4
4-1 5-1 4-1
-10 1.36 -10 5-1 1.36
-100 1 -100 1
Centre: 666.0000 MHz Span: 24.0000 MHz Centre: 666.0000 MHz Span: 24.0000 MHz
Part number BN 61 71 91 BN 61 71 93
Cavities 8 cavities 10 cavities
Frequency range 174 - 230 MHz
Number / Size of cavities 8 / 150 10 / 150
Mask filtering DVB-T @7 MHz DVB-T @7 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB)
-100 1 -100 1
Centre: 858.0000 MHz Span: 24.0000 MHz Centre: 473.0000 MHz Span: 24.0000 MHz
Part number BN 61 65 07
Frequency range 470 - 860 MHz
Number / Size of cavities 4 / 34
Harmonics attenuation ≥ 50 dB for f ≤ 1500 MHz
TV standard DVB-T or ATV @8 MHz DVB-T or ATV @6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB)
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
typical value typical value typical value
dB S11 S21 2-1 1 3-1 VSWR dB S21 S11 42 1 35 VSWR dB S11 S21 2-1 1 3-1 VSWR
4-1 5-1 6 7
0 1.4 0 1.4 0 1.4
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
low profile design
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
low profile design
Part number BN 61 64 02
Frequency range 470 - 860 MHz
Number / Size of cavities 6 / 84
Harmonics attenuation ≥ 50 dB for f ≤ 950 MHz
TV standard DVB-T @8 MHz ISDB-T @6 MHz ATSC @6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
low profile design
Part number BN 61 64 03
Frequency range 470 - 860 MHz
Number / Size of cavities 8 / 84
Harmonics attenuation ≥ 50 dB for f ≤ 950 MHz
TV standard DVB-T @8 MHz ISDB-T @6 MHz ATSC @6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
low profile design
Part number BN 61 64 04
Frequency range 470 - 860 MHz
Number / Size of cavities 4 / 150
Harmonics attenuation ≥ 40 dB for f ≤ 860 MHz
Mask filtering ATV 8 MHz ATV 8 MHz ATV 6 MHz
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
typical value
dB S21 S11 42 1 53 VSWR
6 7
0 8 9 1.4
-10 1.36
-20 1.32
-30 1.28
-40 1.24
-50 1.2
-60 1.16
-70 1.12
-80 1.08
11
-90 10 1.04
-100 1
Centre: 803.000 MHz Span: 24.000 MHz
Part number BN 61 65 72
Frequency range 470 - 860 MHz
Number / Size of cavities 6 / 150
Harmonics attenuation ≥ 50 dB for f ≤ 860 MHz
TV standard ATSC @6 MHz
(Û/Urms = 11 dB)
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
typical value typical value typical value
dB S21 S11 2 1 3 VSWR dB S21 S11 8 1 9 VSWR dB 2 1 3 VSWR
S21 S11
0 1.4 0 1.4 0 4 5 1.4
2
-10 4 5
1.36 -10 3 1.36 -10 1.36
Part number / Connectors BN 61 66 65 C1031 1 5/8" SMS unflanged BN 61 66 65 C2041 3 1/8" SMS unflanged
BN 61 66 65 C1033 1 5/8" EIA BN 61 66 65 C2043 3 1/8" EIA
Cooling natural cooling liquid cooling
Frequency range 470 - 860 MHz
Number / Size of cavities 6 / 170
Harmonics attenuation ≥ 50 dB for f ≤ 1000 MHz
Mask filtering DVB-T @ 8 MHz ISDB-T @ 6 MHz ATSC @ 6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Average input power ≤ 3.75 kW natural cooling ≤ 3.0 kW natural cooling ≤ 3.0 kW natural cooling
≤ 7.50 kW liquid cooling ≤ 6.0 kW liquid cooling ≤ 6.0 kW liquid cooling
Tuning instruction AS6217 AS6222 AS6221
Insertion loss & Mask filtering 470 MHz 860 MHz 470 MHz 803 MHz 470 MHz 803 MHz
(alternative tuning on request) f0 ≤ 0.40 dB ≤ 0.50 dB
f0 ≤ 0.25 dB ≤ 0.35 dB f0 ≤ 0.40 dB ≤ 0.50 dB
f0 ± 3.805 ≤ 0.75 dB ≤ 0.90 dB f0 ± 2.79 ≤ 1.05 dB ≤ 1.25 dB f0 ± 2.69 ≤ 0.60 dB ≤ 0.75 dB
f0 ± 3.885 ≤ 0.90 dB ≤ 1.00 dB f0 ± 3.00 ≥ 3dB f0 ± 3.50 ≥ 3 dB
f0 ± 4.2 ≥ 4 dB f0 ± 3.15 ≥ 5 dB f0 ± 4.00 ≥ 8 dB
f0 ± 6.0 ≥ 20 dB f0 ± 4.5 ≥ 17 dB f0 ± 6.00 ≥ 30 dB
f0 ± 12.0 ≥ 40 dB f0 ± 9.0 ≥ 38 dB f0 ± 9.00 ≥ 65 dB
f0 ± 15.0 ≥ 48 dB
VSWR (pass band range) ≤ 1.15 ≤ 1.15 ≤ 1.15
Group delay variation 6o ≤ 350 ns 6o ≤ 400 ns 6o ≤ 150 ns
Bandpass Filters
installation horizontally or vertically
Bandpassfilter
low profile design
natural or liquid cooling
Part number / Connectors BN 61 66 66 C1031 1 5/8" SMS unflanged BN 61 66 66 C2041 3 1/8" SMS unflanged
BN 61 66 66 C1033 1 5/8" EIA BN 61 66 66 C2043 3 1/8" EIA
Cooling natural cooling liquid cooling
Frequency range 470 - 860 MHz
Number / Size of cavities 8 / 170
Harmonics attenuation ≥ 50 dB for f ≤ 1000 MHz
Mask filtering DVB-T @ 8 MHz ISDB-T @ 6 MHz ATSC @ 6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Average input power ≤ 3.75 kW natural cooling ≤ 3.0 kW natural cooling ≤ 3.0 kW natural cooling
≤ 6.25 kW liquid cooling ≤ 5.0 kW liquid cooling ≤ 5.0 kW liquid cooling
Tuning instruction AS8100 AS8104 AS8103
Insertion loss & Mask filtering 470 MHz 860 MHz 470 MHz 803 MHz 470 MHz 803 MHz
(alternative tuning on request) f0 ≤ 0.45 dB ≤ 0.55 dB
f0 ≤ 0.35 dB ≤ 0.45 dB f0 ≤ 0.4 dB ≤ 0.5 dB
f0 ± 3.805 ≤ 1.10 dB ≤ 1.80 dB f0 ± 2.79 ≤ 1.3 dB ≤ 1.7 dB f0 ± 2.69 ≤ 1.05 dB ≤ 1.40 dB
f0 ± 3.885 ≤ 1.40 dB ≤ 2.00 dB f0 ± 3.15 ≥ 12 dB f0 ± 3.00 ≥ 4 dB
f0 ± 4.2 ≥ 15 dB f0 ± 4.5 ≥ 28 dB f0 ± 3.25 ≥ 18 dB
f0 ± 6.0 ≥ 40 dB f0 ± 9.0 ≥ 54 dB f0 ± 9.00 ≥ 64 dB
f0 ± 12.0 ≥ 55 dB
Part number / Connectors BN 61 64 09 3 1/8" SMS unflanged BN 61 64 09 C0020 3 1/8" SMS unflanged
BN 61 64 09 C0002 3 1/8" EIA BN 61 64 09 C0022 3 1/8" EIA
Cooling natural cooling liquid cooling
Frequency range 470 - 860 MHz
Number / Size of cavities 4 / 200
Harmonics attenuation ≥ 40 dB for f ≤ 800 MHz
Mask filtering ATV 8 MHz ATV 8 MHz ATV 6 MHz
Average input power natural cooling ≤ 7.5 kW natural cooling ≤ 7.5 kW natural cooling ≤ 6 kW
The input power of liquid cooled
filters must be reduced if installed liquid cooling ≤ 14 kW @ 0 - 500 m liquid cooling ≤ 14 kW @ 0 - 500 m liquid cooling ≤ 11.2 kW @ 0 - 600 m
more than 500 m above sea level. ≤ 12 kW @ 1600 m ≤ 12 kW @ 1600 m ≤ 10 kW @ 1300 m
≤ 10 kW @ 2600 m ≤ 10 kW @ 2600 m ≤ 8 kW @ 2600 m
≤ 8 kW @ 3800 m ≤ 8 kW @ 3800 m ≤ 6 kW @ 4000 m
Tuning instruction Standard G: AS4009 Standard I: AS4018
Standard M: AS4033
(alternative tuning on request) Standard K: AS4014
470 MHz 860 MHz 470 MHz 860 MHz 470 MHz 860 MHz
f(V) - 6 > 40.0 dB > 40.0 dB f(V) - 6 > 40.0 dB > 40.0 dB f(V) - 6 > 40.0 dB > 40.0 dB
f(V) - 0.75 MHz ≤ 0.15 dB ≤ 0.20 dB f(V) - 0.75 MHz ≤ 0.20 dB ≤ 0.20 dB f(V) - 0.75 MHz ≤ 0.25 dB ≤ 0.25 dB
f(V) ≤ 0.15 dB ≤ 0.20 dB f(V) ≤ 0.20 dB ≤ 0.20 dB f(V) ≤ 0.25 dB ≤ 0.25 dB
f(S)= f(V) + 6 ≤ 0.15 dB ≤ 0.20 dB f(S)= f(V) + 6 ≤ 0.20 dB ≤ 0.20 dB f(S)= f(V) + 6 ≤ 0.25 dB ≤ 0.25 dB
f(V) + 26 > 40.0 dB > 40.0 dB f(V) + 26 > 40.0 dB > 40.0 dB f(V) + 26 > 40.0 dB > 40.0 dB
Bandpass Filters
DC block
Bandpassfilter
natural or liquid cooling
typical value
dB 2 1 3 VSWR
S11 S21
0 4 5 1.4
-10 6 7 1.36
-20 1.32
-30 1.28
9
-40 8 1.24
-50 1.2
11
-60 10 1.16
-70 1.12
12 13
-80 1.08
-90 1.04
-100 1
Centre: 803.0000 MHz Span: 24.0000 MHz
Part number / Connectors BN 61 65 40 C0010 1 5/8" EIA BN 61 65 50 C0020 3 1/8" SMS unflanged
BN 61 65 50 C0021 1 5/8" EIA
BN 61 65 50 C0022 3 1/8" EIA male
Cooling natural cooling liquid cooling
Frequency range 470 - 860 MHz
Number / Size of cavities 6 / 200
Harmonics attenuation ≥ 50 dB for f ≤ 860 MHz
Mask filtering DVB-T @ 8 MHz ISDB-T @ 6 MHz DVB-T @ 7 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 13 dB)
Average input power natural cooling ≤ 5 kW natural cooling ≤ 4 kW natural cooling ≤ 4.5 kW
The input power of liquid cooled liquid cooling 1 5/8" input ≤ 7 kW liquid cooling 1 5/8" input ≤ 7 kW liquid cooling 1 5/8" input ≤ 7 kW
filters must be reduced if installed liquid cooling 3 1/8" input liquid cooling 3 1/8" input liquid cooling 3 1/8" input
more than 500 m above sea level. ≤ 12.5 kW @ 0 - 500 m ≤ 10 kW @ 0 - 500 m ≤ 10 kW @ 0 - 500 m
≤ 10 kW @ 2000 m ≤ 8 kW @ 2000 m ≤ 8 kW @ 2000 m
≤ 8 kW @ 3200 m ≤ 6 kW @ 3400 m ≤ 6 kW @ 3400 m
Bandpass Filters
DC block
Bandpassfilter
natural or liquid cooling
Part number / Connectors BN 61 65 44 C0010 1 5/8" EIA BN 61 65 54 C0020 3 1/8" SMS unflanged
BN 61 65 54 C0021 1 5/8" EIA
BN 61 65 54 C0022 3 1/8" EIA male
Cooling natural cooling liquid cooling
Frequency range 470 - 860 MHz
Number / Size of cavities 8 / 200
Harmonics attenuation ≥ 50 dB for f ≤ 860 MHz
Mask filtering DVB-T @ 8 MHz ISDB-T @ 6 MHz ATSC @ 6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Average input power natural cooling ≤ 4 kW natural cooling ≤ 3.2 kW natural cooling ≤ 3.2 kW
The input power of liquid cooled liquid cooling 1 5/8" input ≤ 7 kW liquid cooling 1 5/8" input ≤ 7 kW liquid cooling 1 5/8" input ≤ 7 kW
filters must be reduced if installed liquid cooling 3 1/8" input liquid cooling 3 1/8" input liquid cooling 3 1/8" input
more than 500 m above sea level. ≤ 12.5 kW @ 0 - 500 m ≤ 10 kW @ 0 - 500 m ≤ 10 kW @ 0 - 500 m
≤ 10 kW @ 2000 m ≤ 8 kW @ 2000 m ≤ 8 kW @ 2000 m
≤ 8 kW @ 3200 m ≤ 6 kW @ 3400 m ≤ 6 kW @ 3400 m
Part number / Connectors BN 61 66 69 C1041 3 1/8" SMS unflanged BN 61 66 69 C2041 3 1/8" SMS unflanged
BN 61 66 69 C1043 3 1/8" EIA BN 61 66 69 C2043 3 1/8" EIA
Cooling natural cooling liquid cooling
Frequency range 470 - 790 MHz
Number / Size of cavities 6 / 230
Harmonics attenuation ≥ 50 dB for f ≤ 800 MHz
Mask filtering DVB-T @ 8 MHz ISDB-T @ 6 MHz ATSC @ 6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Average input power natural cooling ≤ 8.5 kW natural cooling ≤ 6.75 kW natural cooling ≤ 6.75 kW
The input power of liquid cooled liquid cooling ≤ 18 kW @ 0 - 500 m liquid cooling ≤ 15 kW @ 0 - 500 m liquid cooling ≤ 18 kW @ 0 - 500 m
filters must be reduced if installed ≤ 16 kW @ 1400 m ≤ 14 kW @ 1000 m ≤ 16 kW @ 1400 m
more than 500 m above sea level. ≤ 14 kW @ 2200 m ≤ 12 kW @ 2000 m ≤ 14 kW @ 2200 m
≤ 12 kW @ 3000 m ≤ 10 kW @ 3000 m ≤ 12 kW @ 3000 m
≤ 10 kW @ 3800 m ≤ 8 kW @ 4000 m ≤ 10 kW @ 3800 m
Insertion loss & Mask filtering 470 MHz 790 MHz 470 MHz 790 MHz 470 MHz 790 MHz
(alternative tuning on request) f0 ≤ 0.20 dB ≤ 0.30 dB f0 ≤ 0.30 dB ≤ 0.35 dB f0 ≤ 0.35 dB ≤ 0.40 dB
f0 ± 3.805 ≤ 0.65 dB ≤ 0.80 dB f0 ± 2.79 ≤ 0.75 dB ≤ 0.90 dB f0 ± 2.69 ≤ 0.70 dB ≤ 0.70 dB
f0 ± 3.885 ≤ 0.75 dB ≤ 0.90 dB f0 ± 3.00 ≥ 2 dB f0 ± 3.50 ≥ 3 dB
f0 ± 4.20 ≥ 4 dB f0 ± 3.15 ≥ 8 dB f0 ± 4.00 ≥ 8 dB
f0 ± 6.00 ≥ 20 dB f0 ± 4.50 ≥ 23 dB f0 ± 6.00 ≥ 30 dB
f0 ± 12.0 ≥ 40 dB f0 ± 9.00 ≥ 48 dB f0 ± 9.00 ≥ 65 dB
f0 ± 15.0 ≥ 50 dB
VSWR (pass band range) ≤ 1.15 ≤ 1.15 ≤ 1.15
Group delay variation 6o ≤ 350 ns 6o ≤ 500 ns 6o ≤ 200 ns
Temperature stability ≤ 2 kHz / K
Dimensions (L x W x H) mm 775 x 570 x 352 BN 61 66 69 C1041 781 x 570 x 352 BN 61 66 69 C2041
798 x 570 x 352 BN 61 66 69 C1043 804 x 570 x 352 BN 61 66 69 C2043
Weight ca. 55 kg
Coolant / Flow rate – mix: glycol and water BN 15 45 67 / ≥ 3 l/min
Temperature of the coolant – 10 °C - 55 °C
Cooling interface – stainless steel tube 12 mm x 1 mm unflanged
Cooling accessories – see page annex
Environmental conditions for limitations see „Environmental Conditions for Broadcast Products“
Bandpass Filters
DC block
Bandpassfilter
natural or liquid cooling
Part number / Connectors BN 61 66 70 C1041 3 1/8" SMS unflanged BN 61 66 70 C2041 3 1/8" SMS unflanged
BN 61 66 70 C1043 3 1/8" EIA BN 61 66 70 C2043 3 1/8" EIA
Cooling natural cooling liquid cooling
Frequency range 470 - 790 MHz
Number / Size of cavities 8 / 230
Harmonics attenuation ≥ 50 dB for f ≤ 860 MHz
Mask filtering DVB-T @ 8 MHz ISDB-T @ 6 MHz ATSC @ 6 MHz
(Û/Urms = 13 dB) (Û/Urms = 13 dB) (Û/Urms = 11 dB)
Average input power natural cooling ≤ 8.5 kW natural cooling ≤ 6.75 kW natural cooling ≤ 6.75 kW
The input power of liquid cooled liquid cooling ≤ 16.5 kW @ 0 - 500 m liquid cooling ≤ 13.5 kW @ 0 - 500 m liquid cooling ≤ 16.5 kW @ 0 - 500 m
filters must be reduced if installed ≤ 14 kW @ 1600 m ≤ 12 kW @ 1200 m ≤ 14 kW @ 1600 m
more than 500 m above sea level. ≤ 12 kW @ 2400 m ≤ 10 kW @ 2400 m ≤ 12 kW @ 2400 m
≤ 10 kW @ 3400 m ≤ 8 kW @ 3400 m ≤ 10 kW @ 3400 m
≤ 8 kW @ 4200 m ≤ 6 kW @ 4600 m ≤ 8 kW @ 4200 m
Insertion loss & Mask filtering 470 MHz 790 MHz 470 MHz 790 MHz 470 MHz 790 MHz
(alternative tuning on request) f0 ≤ 0.30 dB ≤ 0.30 dB f0 ≤ 0.35 dB ≤ 0.40 dB f0 ≤ 0.35 dB ≤ 0.40 dB
f0 ± 3.805 ≤ 0.95 dB ≤ 1.00 dB f0 ± 2.79 ≤ 1.05 dB ≤ 1.10 dB f0 ± 2.69 ≤ 0.90 dB ≤ 1.00 dB
f0 ± 3.885 ≤ 1.15 dB ≤ 1.25 dB f0 ± 3.15 ≥ 15 dB f0 ± 3.00 ≥ 4 dB
f0 ± 4.20 ≥ 15 dB f0 ± 4.50 ≥ 30 dB f0 ± 3.25 ≥ 18 dB
f0 ± 6.00 ≥ 40 dB f0 ± 9.00 ≥ 55 dB f0 ± 9.00 ≥ 64 dB
f0 ± 12.0 ≥ 55 dB f0 ± 15.0 ≥ 65 dB
dB
typical value
2-1 1 3-1 VSWR
BN 61 65 11 BN 61 65 13
S11 S21 6-1 7-1
0 1.2 BN 61 65 12 BN 61 65 14
-10 8-1
1.18
9-1
-20 1.16
10-1 11-1
-30 1.14
13-1
-4012-1 1.12
-50 1.1
-60 1.08
-70 1.06
4-1
-80 1.04
5-1
-90 1.02
-100 1
Centre: 1.472 GHz Span: 6.000 MHz
Part number BN 61 65 11 BN 61 65 13 BN 61 65 12 BN 61 65 14
Connectors 7-16 female 1 5/8" EIA 7-16 female 1 5/8" EIA
Frequency range 1452 - 1468 MHz 1468 - 1492 MHz
Number / Size of cavities 4 / DM
Mask filtering DAB / T-DMB @ 1.54 MHz
(Û/Urms=13 dB)
Bandpass Filters
DC block
Bandpassfilter
typical value
dB 2-1 1 3-1 VSWR
S11 S21 6-1 7-1
0 1.2
-10 8-1
1.18
9-1
-20 1.16
10-1 11-1
-30 1.14
13-1
-4012-1 1.12
-50 1.1
-60 1.08
-70 1.06
4-1
-80 1.04
5-1
-90 1.02
-100 1
Centre: 1.472 GHz Span: 6.000 MHz
Part number BN 61 65 16
Frequency range 1452 - 1492 MHz
Number / Size of cavities 4 / DE
Mask filtering DAB / T-DMB @ 1.54 MHz
(Û/Urms = 13 dB)
SWS
SPINNER WAVELENGTH SHRINKING | STRETCHING
BN 61 63 95 BN 61 64 52 C0011
dB S21 dB S21
10 0
1 2
0 -10
3
-10 -20
4
-20 -30
-30 -40
5
-40 -50
-50 -60
6
-60 -70
-70 -80
-80 -90
-90 -100
Start: 200.0000 MHz Stop: 2.4000 GHz Start: 100.0000 MHz Stop: 2.6000 GHz
Bandpass Filters
Bandpassfilter
Pump unit and UHF combiner with liquid cooled filter Pump unit and indoor cooler
Coolant
25 l can with coolant (mix glycol and water and anti corrosive) BN 15 45 67
Cooler