DATE: 14-FEB.-O7
PRODUCTION ORDER:
CUSTOMER
GB-302 (REPARACION)
CONE ROOF
ANCHOR
DESIGN DATA
COURSE 2
COURSE 3
COURSE 4
COURSE 5
Td = {2.6*O*(H-1)*G/Sd} + CA 0.079
Tt = {2.6*O*(H-1 )/St}
3.8 A-283-GR C 0.079 0.1875 3/16"
0.015
Per API 3.6.1.1 the minimum Shell thickness including corrosion allowance shall be not less than 3/16" for nominal tank diameter <50 ft
3DE 14
BOTTOM AND ROOF PLATES
CODE: API 650 -TENTH EDITION -NOV. 1998. (ADDENDUM 3, MARCH 2003)
The wind loading or pressure shall be assumed to be on projected areas of cylindrical surfaces
for wind velocity other than 100 mph the loads shall be adjusted by (V/100)2
CALCULATIONS:
Overturning Moment
lifting force due to internal pressure on the roof (if applica! Wlev 0 Ib
FUNCTIONS Where:
Data
R.= O.2~
87in in .= 6.3 in
'-= W,= 4.4 in
t.= 0 1875 in R.= 1745 in
.!=. 9.48 d rees
~
M=
1 2.02671 in water 1
I 1.7102lin2 I
The minimum angle area required (from the total subtract the shell and roof participating area
Functions Where:
Wh=
W,=
Data
i4.4
.3 A.=
Calculations
~ in' !
~ 0.25
10= 10.1875 1
~
SEISMIC DESIGN OF STORAGE TANKS
CODE: API 650 -TENTH EDITION. NOV. 1998. (ADDENDUM~, MARCH 2003)
DESIGN DATA
W1=(Weight of the effective mass of the tank contents that move in unison with the tank shell) E.3.2.1
W2=(Weight of the effective mass of the tank contents that move in the first sloshing mode) E.3.2.1
D/H
X1=(Height from the bottom of the tank shell to the centroid of lateral seismic force applied to W1) E.3.2.2
X2=(Height from the bottom of the tank shell to the centroid of lateral seismic force applied to W2) E.3.2.2
T=k*DA1/2
1 DE2
SEISMIC DESIGN OF STORAGE TANKS
WI=(Maximum weight of the tank contents that may be used to resist the shell overtuming moment, of shell circumference) PER API -650 E4
WI max < WI Gal, then WI max shall be used 1661 Ibslft of shell circumference
API App E,5,1 portion of the fIXed roof supported by the shell assumed 50%
Wt=(Weight of the tank shell and the portion of the fixed roof supported by the 354 1 Ibslft of shell circumference
Resistance to Overturning
Wt+WI 2015 Ibslfl of shell circumference
SHELL COMPRESSION
To confim ff M I DA2 (Wt + WI) > 0,785 but less < 1,5, b may be computed from the parameter of Figure E-5
Maximum longitudinal compressive stress in the shell Frnax = b/12*t 285 psi
When GHD2/( is greater than 106, then Fa = 106*t/D Fa = 3923 psi Case 1
"or"
When GHD21 t' is less than 106, then Fa = 106ot/2,5°D + 600 °.J (HoG) Fa = psi Case 2
2 DE2
ANCHORAGE OF TANKS DUE TO SEISMIC MOMENT (IF REQUIRED)
CODE: API 650 -TENTH EDITION -NOV.199~.1iD5~~5~~-;:~~~CH 2003)
Anchoraae Boits
Anchors shall be spaced a maximum of 10 It On tanks less than (SO It) in diameter or 6 It Per API -E.6.2.2
Care should be laken to ensure that the specified minimum yield strength of the anchors so that
Allowable tensile stress = Sadm = O.8Sy Per API E 6.2.3., Sadm = 28800 Psi
The Stresses due to anchor forcer in the tank shell as per AlSI E-1 VOLUME II. PART VII.
b=(Maximum longitudinal compressive force at the bottom of the shell) 641 Ibslft of shell circumference
N = Number of supports
H = Support height
Z = Reduction factor
Z = 1/0, 177*A*m/(R*t)"O,5im/t)A2 + 1
z= 0.989
P*E/t"2 118.81
1,32*Z 1.305
1,43*A*HA2/R*t 5.744
(4*A *HA2)'O,333 11.970
O,O31/(R*tjAO,5 0.003
s= 9112 psi < 25000 psi Stress due to anchor bolts is adequatelly
CONICAL ROOF STRUCTURE CALCULATION
DESIGN DATA
r=(lnter radius of the sheii) 7.28 m 23.9 It
ht=(Roof height) 1.21 m 3.98 It
A = Roof area = Pl*r*RAIZ(r + h2}
169.0 m2
Roof piate thickness 0.2500in
Roof weight caiculation 49.85 kgim2
For a conical roof the maximum separation of beams (rafters) in the periphery Is:
S max = t' SORT (2*f/P) 8.3 ft > 6.28 Not adequately as per (API 350 3,10,4,4)
Number of beams (rafters) within the outer nng tank Nv = 0'3.1416/6,28 24 beams
Real spaced between rafters within the outer ring Pr I Nv = 5.78 ft < 6.28' ft (API-650)
,
DESIGN FORMULAS
R1=R2=WU2
M = W,X/2)*(L-X)
G=M/Z
DATA
L= 7250 "VT1
w= 0.154 Kgimm
E= 20400 Kgimm2
X=L/2=
ASSUMED SHAPE FDR THE RAFTERS C 6"x 8.2 Ibs/ft (150 x 12.203 kg/mt)
13440000 mm4
7250 mm
W = Distributed loads (Roof ioad + load of the shape) I Length of the shape
0.1712 Kg/mm
E= 20400 KgirTVT12
X=L/2= 3625 mm
M = W*(X/2)*(L-X) 1124723 kg
ASSUMED SHAPE FOR THE RAFTERS C 6"x 8.2 Ibs/ft (150 x 12.203 kg/mil
6000 rTrn
z= 4.38 in3
8356000 ~
COLUMN. CALCULATION
Total of shapes 34
P = Loads = 21098 kg
DESIGN CALCULATIONS
fm (Actual) = PIA
6429 psi
C 14" .34 Lb I Ft