You are on page 1of 1

INVERTER FMZ MAIN MOTOR /ROLL :

485+ HMI SOKET DB9 No.2


485- HMI SOKET DB9 No.1
X1 Y8 (RUN)
X3 Y9 (LOW-SPEED)
GND 0VDC
TA RELAY TRAFO TREET
TC 0VDC
+10V POTENSIO KIRI
AV1 POTENSIO TENGAH
GND POTENSIO KANAN
SETTINGAN INV FMZ UTAMA & ROLL :
P0.02 1 (RUN DARI TERMINAL)
P0.03 6 (SPEED FROM RS-485)
P0.04 60,00 HZ (MAX FREQ)
P0.05 60,00 HZ (UPPER FREQ)
P0.10 0.8 (AKSELERASI)
P0.11 0.8 (DEKSELERASI)
P1.04 1 (WITH BRAKE), 0 (NO BRAKE)
P2.13 3 (X1 FOR RUN INVERTER)
P2.15 0 (X3 NONE)
P2.20 2 (RELAY ON INVERTER RUN)
P6.00 1 (UNTUK MAIN MOTOR),
2 (UNTUK ROLL BELAKANG A)
3 (UNTUK ROLL BELAKANG B)
4 (UNTUK ROLL BELAKANG C)
5 (UNTUK ROLL BELAKANG D)
P6.01 0010 (9600 bps,E,8,1)
SETTINGAN INVERTER FMZ ROLL :
P0.02 1 (RUN DARI TERMINAL)
P0.03 03 (SPEED FROM AV1)
P0.04 60,00 HZ (MAX FREQ)
P0.05 60,00 HZ (UPPER FREQ)
P0.10 0.8 (AKSELERASI)
P0.11 0.8 (DEKSELERASI)
P2.13 3 (X1 FOR RUN INVERTER)

You might also like