MEC-2000

PATIENT MONITOR
12.1" color TFT with maximum 8 waveforms

Suitable for adult, pediatric and neonatal patients

Parameters including ECG, RESP, SpO2, NIBP,2-TEMP, 2-IBP, C.O., EtCO2

96-hour graphic and tabular trends of all parameters

Optional built-in recorder and CF card (for power off storage)

Networkable with central monitoring system


Parameters: ECG, RESP, NIBP, SpO 2, 2-TEMP, 2-IBP, C.O, EtCO2

MEC-2000
PATIENT MONITOR
Technical Specifications
Safety Alarm range: 15~350bpm Accuracy: 3bpm(non-motion);
IEC60601-1 approved S-T segment detection: YES 5bpm(motion)
Measurement range: -2.0mV~2.0mV Temperature
Dimension and Weight Alarm range: -2.0mV~2.0mV Measurement: Range: 0~50 (32~122 )
Dimension: 318mm (W) x 270mm (H) x 145mm (D) Arrhythmia analysis: YES Resolution: 0.1
Weight: 4.7 kg Alarm: YES, audible and visual alarm, Accuracy: 0.1
alarm events recallable Channel: Dual-channel, provide T1; T2; T
Operation Environment Pace detection: YES Alarm: 3-level audible and visual alarm
Power requirement: AC100-240V, 50Hz/60Hz
Respiration IBP
Performance Specifications Method: Thoracic impedance Measurement range: -50~300mmHg
Display: 12.1" color TFT(diagonal) Measurement Range: Adult: 0-120BrPM; Channel: 2 channels
Rolling and refreshing waveform display Neonata;/Pediatric: 0-150BrPM Pressure Transducer: Sensitivity: 5 V/V/mmHg
Trace: 8 waveforms Apnea alarm: YES Impedance range: 300~3000
Resolution: 800X600 Alarm: YES,audible and visual alarm, Pressure names: ART, PA, CVP, RAP, LAP, ICP, P1, P2
alarm event recallable Resolution: 1 mmHg
Multi displays selectable: Accuracy: 2% or 1 mmHg whichever is greater
Standard screen display NIBP Alarm range: -10~300mmHg
Trend coexist screen display Method: Automatic oscillometric
OxyCRG screen display Operation modes: Manual/Automatic/Continuous C.O.(Cardiac Output)
Viewbed screen display Auto measure time: Adjustable Method: Themodilution
Large-font screen display Measurement unit: mmHg / kPa selectable Measurement range: CO:0.1~20 l/min
Lead-Acid battery: Rechargeable Measurement type: Systolic,Diastolic,Mean TB: 23~43
(for 2 pieces) Maximum 12 hours for charging; Measurement range: TI: 0~27
2 hours for continuous working Range of Systolic pressure: Resolution: CO:0.1 l/min
Trend time: 1-96 hours Adult mode: 40-270mmHg TB: 0.1
Alarm: User-adjustable High and Low limits Pediatric mode: 40-200mmHg TI: 01
3-level audible and visual alarm Neonatal mode: 40-135mmHg Accuracy: CO 5% or 0.1 l/min
Networking: Connected to central monitoring system Range of Diastolic pressure: TB: 0.1
Recorder: Built-in, thermal array, 2 channels Adult mode: 10-210mmHg TI: 01
Record mode: manual, on alarm, Pediatric mode: 10-150mmHg Parameter output: Cardiac output; Hemodynamics
time-defined, etc. Neonatal mode: 10-100mmHg calculation
Print speed: 25mm/s, 50mm/s Range of Mean pressure:
Adult mode: 20-230mmHg EtCO2
ECG Pediatric mode: 20-165mmHg Method: Infrared Absorption
Lead type: 5-lead and 3-lead selectable Neonatal mode: 20-110mmHg Measurement Mode: Sidestream
Input: 5 leadwire cable: RA; LA; RL; LL; V Accuracy of blood pressure measurement: Measurement range: EtCO2: 0~99mmHg
(or R; L; N; F;C) The mean error shall be less than 5mmHg Accuracy: 2mmHg(0~40mmHg)
3 leadwire cable: RA; LA; LL or R; L; F The standard deviation shall be less than 8mmHg 5% of reading (41~76mmHg),
Lead selection: 5 lead: ; ; ; avR; avL; avF; V Over-pressure protection: Double safety protection 10% of reading (77~99mmHg)
3 Lead: ; ; ; Resolution: 1mmHg Sampling rate: 100 or 150ml/min
Gain selection: x0.125;x0.25;x0.5; x1; x2; auto Alarm: Systolic, Diastolic, Mean Sampling rate accuracy: 0.15
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s Start-up time:
Heart Rate range: Adult: 15-300bpm, SpO2 <1min. the module enters the warming up status
Pediatric/Neonate 15-350bpm Measurement range: 0~100% after the startup.
Resolution: 1bpm Resolution: 1% 10 minutes later, it enters the ready-to-measure status
Accuracy: 1bpm or 1%, whichever is greater Accuracy: Respiration rate: 0~120BrPM
Bandwidth: Diagnostic mode: 0.05~100Hz 2% (70%~100%, Adult/Pediatric, non-motion) Respiration rate accuracy: 2BrPM (0~70BrPM)
Monitoring mode: 0.5~40Hz 3% (70%~100%, Neonate, non-motion) 5BrPM (>70BrPM)
Surgical monde: 1~20Hz 3% (70%~100%, Adult/Pediatric/Neonate, motion) Response time: <240ms(10% to 90%)
Protection: Withstand 4000VAC/50Hz voltage in 0~69% unspecified Delay time: < 2s (Sampling line length:7inches; internal
isolation. Against electrosurgical Alarm range: 1~100% diameter:0.055 inches, sampling gas flow
interference and defibrillation Pulse Rate: Range: 20~254bpm rate: 150ml/min)
Scaling Signal: 1mV 5% Resolution: 1bpm

Standard Configuration: ECG, NIBP, RESP, Mindray SpO2 , PR, Dual-TEMP, Lead Acid Battery
Optional Configuration: Dual-IBP, CO, EtCO2 (side-stream), Thermal recorder, CF Card (for power off storage)

P/N:ENG-MEC2000-210285-20070718