Professional Documents
Culture Documents
OUT OF SERVICE
KG
Programming
jumper Call buttons
Serial
Board
PARAMETERS RELATED TO THE TYPE OF SIGNAL CARRIED OUT BY THE OUTPUTS AND TO FLOOR NUMBERING ON SERIAL BOARD AND
DISPLAY (TO BE MODIFIED ON THE EURO BOARD IN THE CONTROL PANEL)
PELAZZA PEPPINO s.r.l.
Quadri di Manovra per Ascensori e Montacarichi
Lifts Control Panels
20063 CERNUSCO SUL NAVIGLIO (MI) ITALY
Via Ponchielli, 6/8
Tel. 02/9231694 – 02/9242706 – Fax 02/9242706
www.pelazza.com
E-mail: pelazza@pelazza.com
PROGRAM: EURO-INV13N CLIENT: MILAN ASCENSORE Ref: MARCH 2015 MRL 5.5 KW -
12PE-PA-S 2 ACC. - OP.380V3PH
Lift: VVVF – Simplex 1PE – Automatic Doors – Closed Doors Parking – Serial
1 6 (def.) TMA = Maximum opening doors time (to be regulated about 1-2 sec over
the time required to open the doors)
5 6 TMP = Engagement manoeuvre time and A67 fault signal time (5xP5 sec)
9 4 TOC = Engage time from closing doors start for parking (to be regulated
about 1-2 sec over the time required to close the doors)
11 20 TRIF = Contactrors drop delay at stop: 7 (Inverter without encoder 27x0,1=0,7 sec)
20 (Fuji 20x0,1= 2,0 sec)
25 2 Automatic re-phasing
26 6 Inspection in high+low speed (reduced by VVVF) with stop on the re-phase impulsors
27 0 (def.) 0 = Fixed Confirmation Control and Directions signalling
30 2 2 = 30KG floor contact (CCO) disabled + full load contact (CCC) enabled
0 = 30KG floor contact (CCO) enabled + full load contact (CCC) enabled
36 2 Floors number
Milan Ascensore Rif.Ord. March 2015 MRL 5,5KW 1/2Acc. OP.380V3PH V= 1m/s
F03 Motor speed regulation (reference for acc/dec time) 119 r/min
F04 Motor rated speed (reference for motor supply voltage) 119 r/min
F1B F1A
F2B F2A
F3A
F3B
PC
BC2
VEGA
SERCAR_LCD_2.4
CP LLR TD CP CP SA CP
V1
V2
BPR SF AF