You are on page 1of 3

ECG Project Name

Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


CRANE GIRDER ID :- ( C.G-1 ) Refrences
ECP
1)- APPLIED FORCES :- Steel grade St.52
Fy = 3.60 t/cm2
Max wheel load = 7.15 t Fu = 5.20 t/cm2
Wheels spacing = 3.00 m
Crane girder span = 5.00 m
Impact factor = 25.00 %
Cb = 1.35
P P ECP P20

2)- CHOISE OF SECTION :-

The section is Built Up Section


bFLU = 225.00 mm
tFLU
hWeb
=
=
10.00
450.00
mm
mm
wheel spacing
tWeb = 5.00 mm
bFLL = 175.00 mm
tFLL = 8.00 mm bu
1 2
3)- CHECK SECTIONS :- tfl.u
PROPERTIES OF SECTION :-

Wt. = 46.32 kg/m


Y = 26.64 cm hw tw
A = 59.00 cm2
Ix = 22386.62 cm4
Iy = 1306.98 cm4
Sx.top tfl.l
Sx.bott
= 1110.30 cm3
3
= 840.42 cm3
Sy
bL
= 116.18 cm3
rx = 19.48 cm
ry = 4.71 cm

4)- LOADS ON CRANE GIRDER :-

a) DEAD LOAD :-
MD.L = 0.14 mt
QD.L = 0.12 t

a) LIVE LOAD (WITH IMPACT) :-


ML.L = 10.948 mt
QL.L = 12.513 t

a) DESIGN VALUES :-
MX = 11.09 mt
MY = 0.88 mt
QX = 12.63 t

CHECK COMPACTNESS :-

dw/tw = 90.000 Web is Non compact table(2.1a)


C/tf = 11.000 Flange is Non compact table(2.1c)
The sec is Non compact
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


CHECK BENDING STRESSES :-

( 20.bf ) / (√ fy ) = 2.372 m ECP 16


Lumax = 2.372 m
( 1380.Af ) / ( fy.d ) x Cb = 2.59 m eqn. 2.18
Lu.act = 2.00 m
Lateral torsional buckling of comp.flange There is no LTB
Fbcx = 2.088 t/cm2
Fbt = 2.088 t/cm2

POINT 1 "subjected to Mx only on compression flange" :-

f1 = 1.00 t/cm2 < 2.088 t/cm2 SAFE

POINT 2 "subjected to Mx and My on compression flange" (Case B) :-

f2 = 0.84 < 1.2 SAFE

POINT 3 "subjected to Mx only on tension flange" :-

f3 = 1.32 t/cm2 < 2.088 t/cm2 SAFE

CHECK SHEAR STRESSES :-

qw = 0.56 t/cm2 < 1.260 t/cm2 SAFE

CHECK DEFLICTION :-

δL.L = 0.456 cm < 0.63 cm SAFE


ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.

You might also like