You are on page 1of 1

16000

4000 4000 3000 5000

300 300 300 300 300


200

200

200

200

200
C3(20x30) C3(20x30) C3(20x30) C3(20x30) C3(20x30)
50 50

4000
50 50
300 300 300 300 300
200

200

200

200

200
C3(20x30) C3(20x30) C3(20x30) C3(20x30) C3(20x30)

NOTE :
1. ALL DIMENSION ARE IN MILLIMETERS
EXCEPT INDICATED.
FIRST FLOOR COLUMN LAYOUT PLAN 2. ALL LEVELS ARE IN METERS EXCEPT
INDICATED.
SCALE 1:70 3. CHARACTERISTIC CYLINDER COMPRESSIVE
STRENGTH OF CONCRETE SHALL BE MINIMUM
OF 25MPa AT 28 DAYS.
4. REINFORCING STEEL YIELD STRENGTH TO BE
A MINIMUM OF:
- 390MPa FOR DEFORMED BAR (DB).
- 235MPa FOR ROUNDED BAR (RB).
5. CLEAR COVER SHALL BE 30mm UNLESS
INDICATED OTHERWISE.