Safety Management System Manual

Chapter 10
PANTHALASSA
MARITIME CORP. E35 Revision No. 00
CRITICAL EQUIPMENT CHECKS WITH
PERFORMANCE DATA
ONBOARD FOLDER NO. 9B PERIODICITY: Monthly

CRITICAL EQUIPMENT & SYSTEMS STATUS TESTING


This form to be sent to the Office EVERY month, unless its contents are incorporated in the ePMS functions in use.

Vessel : MV ANGELIC GLORY Date : MAY 2020

Performance Data
Interval Date last ACTUAL
Description MAKERS SET
tested DESCRIPTION MEASURED
POINT
VALUE
Hydraulic Pressure 20MPA
MAY 2, 2020 -
(bar):
Hydraulic Pressure - 20MPA
MAY 9, 2020
(bar):
Steering gear
MAY 16, Hydraulic Pressure - 20MPA
1. hydraulic pump Weekly
2020 (bar):
& El. Motor
MAY 23, Hydraulic Pressure - 20MPA
2020 (bar):
MAY 30, Hydraulic Pressure - 20MPA
2020 (bar):
2. Emergency Monthly MAY 15, Time to go from 15
steering gear 2020 PRIOR deg port to 15 stbd
system LEAVING (sec): 60 s 15 sec
ROSARIO,
ARGENTINA
3. UMS alarms CARRIED OUT UMS
(when vessel MAY 30, ALARMS
- -
operates in 2020
UMS mode)
Limit of mist (ppm or
MAY 2, 2020 2.73% 3.0%
%) or alarm
Limit of mist (ppm or 2.73% 3.0%
MAY 9, 2020
M/E crankcase %) or alarm
4. oil mist detector. Weekly MAY 16, Limit of mist (ppm or 2.73% 3.0%
2020 %) or alarm
MAY 23, Limit of mist (ppm or 2.73% 3.0%
2020 %) or alarm

5. Main Engine MAY 15, Activation:


emergency stop 2020 PRIOR ME LO INLET LOW
system Weekly LEAVING PRESSURE - ACTUAL
ROSARIO,
ARGENTINA
6. Boiler alarms LOW LEVEL ALARM
MAY 11,
and emergency LOW LOW LEVEL - -
2020
shut-downs ALARM
7. Auxiliary Boiler 12 Months NO Safety Valve Setting
- -
safety valves RECORDS (MPa):

Note 1: The status/performance of Critical Equipment is verified by Crew on board as per defined intervals established by the PMS.

8. Main Engine Weekly MAY 15, El. Load (kw):


alarms and 2020 PRIOR duration time of test
emergency shut- LEAVING (min): N/A -
downs. ROSARIO,
ARGENTINA
El. Load (kw): N/A -

Page 1 of 4
Safety Management System Manual
Chapter 10
DILIGENT HOLDINGS S.A. E35 Revision No. 00
CRITICAL EQUIPMENT CHECKS WITH
PERFORMANCE DATA
ONBOARD FOLDER NO. PERIODICITY: Ad Hoc

MAY 15, El. Load (kw):


2020 PRIOR duration time of test
LEAVING (min): N/A -
ROSARIO,
ARGENTINA
duration time of test
Main Engine (min):
alarms and El. Load (kw):
8. Weekly
emergency shut- duration time of test N/A -
downs. (min):
El. Load (kw):
duration time of test N/A -
(min):
El. Load (kw):
duration time of test N/A -
(min):
9. E/R quick closing MAY 30, System pressure
Weekly - 7 KGF/CM2
valves 2020 (bar):
10. Emergency air Time needed to fill
compressor D/G start air
MAY 30,
Weekly receiver N/A ACTUAL
2020
(min):CHECKED
ENGINE.
11. Navigation Lights Weekly MAY 30, NAV LIGHTS
- -
2020
12. Emergency Weekly CHECKED
batteries and BATTERIES AND
MAY 30,
charger for BATTERY - -
2020
communication CHARGER.
equipment
13. Ventilation ducts Weekly ER VENT FANS
MAY 30,
fire dampers AND FUNNEL - ACTUAL
2020
DAMPER
14. Remote shut Weekly MAY 15, CARRIED IN
down devices 2020 PRIOR ENGINE
LEAVING CONTROL ROOM - -
ROSARIO,
ARGENTINA
15. Breathing Weekly CHECKED
MAY 30,
Apparatus COMPRESSOR. - -
2020
Compressor
Update voyage
- charts, as N/A N/A
applicable.
Update voyage
- charts, as N/A N/A
applicable.
ECDIS (if installed
Update voyage
and used for
16. weekly - charts, as N/A N/A
navigational
applicable.
purposes)
Update voyage
- charts, as N/A N/A
applicable.
Update voyage
- charts, as N/A N/A
applicable.
17. Fire detection and Weekly All points active:
MAY 2, 2020 N/A ACTUAL
alarm system SMOKE SENSOR
MAY 9, 2020 All points active: N/A ACTUAL
SMOKE SENSOR

Page 2 of 4
Safety Management System Manual
Chapter 10
DILIGENT HOLDINGS S.A. E35 Revision No. 00
CRITICAL EQUIPMENT CHECKS WITH
PERFORMANCE DATA
ONBOARD FOLDER NO. PERIODICITY: Ad Hoc

MAY 15, El. Load (kw):


2020 PRIOR duration time of test
LEAVING (min): N/A -
ROSARIO,
Main Engine ARGENTINA
alarms and
8. Weekly MAY 18, All points active: ACTUAL
emergency shut- N/A
2020 SMOKE SENSOR
downs.
MAY 16, All points active: ACTUAL
N/A
2020 SMOKE SENSOR
MAY 30, All points active: ACTUAL
N/A
2020 SMOKE SENSOR

All points active:


MAY 2,
FWD PORT/STBD, N/A ACTUAL
2020
AFT BILGE
All points active: ACTUAL
MAY 9,
FWD PORT/STBD, N/A
2020
AFT BILGE
MAY All points active: ACTUAL
18. E/R bilge alarms Weekly 18, FWD PORT/STBD, N/A
2020 AFT BILGE
MAY All points active: ACTUAL
16, FWD PORT/STBD, N/A
2020 AFT BILGE
MAY All points active: ACTUAL
30, FWD PORT/STBD, N/A
2020 AFT BILGE
MAY 2, Pressure (bar):
- 8 KGF/CM2
2020
MAY 9, Pressure (bar): 8 KGF/CM2
-
2020
MAY Pressure (bar): 8 KGF/CM2
18, -
19. Emergency fire pump Weekly 2020
MAY Pressure (bar): 8 KGF/CM2
16, -
2020
MAY Pressure (bar): 8 KGF/CM2
30, -
2020
MAY 2, Water jet: 8 KGF/CM2
-
2020
MAY 9, Water jet: 8 KGF/CM2
-
2020
MAY Water jet: 8 KGF/CM2
18, -
Fixed fire extinguishing
20. Weekly 2020
system
MAY Water jet: 8 KGF/CM2
16, -
2020
MAY Water jet: 8 KGF/CM2
30, -
2020
21. Lifeboats and related MAY Oil level in winch
equipment Weekly 30, visible: N/A YES
2020
22. Radar & ARPA Weekly - - - -
23. OWS & OCM MAY
LIMIT PPM
Weekly 30, - 15 PPM
CONTENT
2020

Page 3 of 4
Safety Management System Manual
Chapter 10
DILIGENT HOLDINGS S.A. E35 Revision No. 00
CRITICAL EQUIPMENT CHECKS WITH
PERFORMANCE DATA
ONBOARD FOLDER NO. PERIODICITY: Ad Hoc

All points active:


MAY 2,
FWD PORT/STBD, N/A ACTUAL
2020
AFT BILGE
18. E/R bilge alarms Weekly
24. Incinerator MAY
SAFETY
Weekly 30, - -
DEVICES/ALARMS
2020
25. Sewage Treatment MAY
Plant (STP) Weekly 30, HIGH LEVEL ALARM - -
2020
26. Portable gas and LEL% against span
oxygen detectors gas
Weekly - - -

REMARKS (IN CASE OF DEFECT OR ABNORMALITY):


________________________________________________________________________________________
________________________________________________________________________________________
________________________________________

Ch. Engineer Ch. Officer Master

(Full Name, Signature, date)

Page 4 of 4