STERLING & wisonA> 2 Date: 13/10/2018 To, Sir Gangaram Hospital RajinderNagar New Delhi SUBJECT Design verification of Mono-slope Solar Module Mounting Structure as per DWG: SWL-CS3-164kWp-DWG-MMS-9 The Solar Module Mounting Structure as per the following documents is considered for design verification: 1 GA DWG- SWL-CS3-164kWp-DWG-MMS-9 zz STAAD report — CP_48MMS- -3 PILLAR-MLCP-DT 27-03-2018 3. Wind Load calculation sheet The given structure is verified as a mono-slope free roof type of structure, with tilt up to 5°, against wind loads for basic wind speed of 47 m/s (170 kmph), for 25 yeats of reliability level as per 15-875 (Part-3)-1987. Based on the design verification and analysis, the structure is found to be safe for the intended application for the specific site condition. For Sterling and Wilson Pvt Ltd (Thejas H k) Senior Engineer B.E. (Civil) M-Tech (Structural Engineering) Sterling and Wilson Private Limitod Associates of: Shapoori Pallonji and Company Private Limited Registered Office: Universal Majestic, Sth Floor, P.L. Lokhande Marg, Chembur (W), Mumbai - 400 043 Branch Office: No. 4/14, Gth Main, Chikka Audugodi New Exin, Thavarekere Main Road, Bengaluru ~ 560029 Phone: (91-80) 67596100 - 01 Fax: (91-80) 6759 6175 Email: bengaluru@sterlingwilson.com | waww.steriingandwilson.com | CIN: U31200MH1874PTCO17538 ENGINEERS CITADEL for engineering solutions. Ref: ECPV/SNW/0618/10 Date: 06/10/2018 To, Sterling and Wilson Pvt Ltd, Tavarekere Main Road, Bengaluru-560029 SUBJECT : _ Design verification of Mono-slope Solar Module Mounting Structure as per DWG: SWL-CS3-164kWp-DWG-MMS-9 Dear Sir, The Solar Module Mounting Structure as per your submission of following documents is considered for design verification: 1. GA DWG- SWL-CS3-164kWp-DWG-MMS-9 2, STAAD report ~ CP_48MMS- -3 PILLAR-MLCP-DT 27-03-2018 3. Wind Load calculation sheet The given structure is verified as a mono-slope free roof type of structure, with tilt up to 5°, against wind loads for basic wind speed of 47 m/s (170 kmph), for 25 years of reliability level as per IS-875 (Part-3)-1987, Based on the submitted design and analysis report document referred above, the structure is found to be safe for the intended application for the specific site condition. For ENGINEER'S CITADEL, ’ \ K IRISHIR. oy = @ i? BE, ME. per HAL Chartered Engineer (Ifa) INDER BHUSHANTPANCE 379652 Ti RE ENGINEER : TRUCTU fi ‘Bongolura 850085" ifeD Liane No, SEI204 engalurd~ 850088, D Lean eT (GIRISH J R) Chartered Engineer (India) No ~IE-M1379652 ENGINEERS’ CITADEL, Bengaluru-560085, Mail: engineerscitadel @gmail.com ; Ph: #91 9900552528, Perea feiss rena festtotae mea ane sg Tg Fea ITE in wnepeae EEE etd res fea par ae 7 page no a le 7 pape nn Te ge a mat] pai Sai ie Pent nat ean wen OA ina Pasa. 0 4 Bi Chartered Engineer (india) No, 1379682 ENGINEERS CITADE? Bensgaluru - 588 6 1 ST PANCHAL ‘STRUCTURE ENGINEER MCD Licence No. SEI0204 1M, No. 9809147804 of ERO ie mounted slong aide foe ofthe le cd ee aeranaeeal via en pear oie. Down revue conte es Ups prea OOF sen donnwind pressure OOF agp apart oe oa ach mote [Psigndomnvindtoree on ea noe [DSC ea Pa me meng mabe onewin oWn [roam [zeae weit UOT ng te mba seer rime ul [ewan mas ws a0 sper 7 oat eT sae (0 INBERYERUSHAN PANCHAL STRUCTURE ENGINEER MCD Licence No. SE/0204 M. No, 9899147804

You might also like