Professional Documents
Culture Documents
Geotechnical parameters
Depth(m)
Ultimate skin friction Ultimate bearing
From To (kPa) (kPa)
0 0.75 0 0
0.75 2 25 0
2 6 25 330
> 6 100 1500
Compression
Row Pile Section Material yield (KN)
1C Central HEA-140 275 12.9
1C Central HEA-140 275 0.6
1C Lateral IPE-160 355 17.5
2C Central HEA-140 275 10.6
2C Central HEA-140 275 0
2C Lateral CP140X50X20X3 355 14.5
3C Central IPE-140 275 5.4
3C Central IPE-160 275 0.1
3C Lateral CP140X50X20X3 355 14.5
4C Central HEA-140 275 10.6
4C Central HEA-140 275 0.2
4C Lateral CP140X50X20X3 355 14.5
5C Central IPE-140 275 5.4
5C Central IPE-140 275 0.1
5C Lateral CP140X50X20X3 355 14.5
1 There will be challenge to rammed the pile with Section CP140x50x20x3 as it has tendency to rora
2 Section size may get changed due to depth of Pile 3.6-3.7m due to frost heave consideration.
3 There is an assumption taken that pile under compression due to wind load to have less chance wi
4 As per ASCE, EOR agreement on Adfreeze force (upward) is required. Else Pile embedded depth ma
Date : 16Mar2020
Frost Assumptions Geotechnical Resistance factors
Flange
Uplift Shear Moment Area Depth,H width Perimeter
(KN) (KN) (KN-m) (mm2) (mm) (mm) (mm)
0 7 -9.4 3140 133 140 546
0 0.9 7.3 3140 133 140 546
0 8.5 10 2010 160 82 484
0 12.7 -2.8 3140 133 140 546
0 12.6 1.7 3140 133 140 546
0 2.4 2.8 775 140 50 380
0 -4.6 -5.4 1640 140 73 426
0 7 8.8 2010 160 82 484
0 1.8 2.2 775 140 50 380
0 11.1 -1.4 3140 133 140 546
0 10.7 1.2 3140 133 140 546
0 1.8 2.2 775 140 50 380
0 -4 -4.8 1640 140 73 426
0 5.8 7.3 1640 140 73 426
0 1.7 2 775 140 50 380
ome EOR may agree with 0.8 value for Uplift. 2000 psf = 95 kN/sqm