You are on page 1of 2

Serachem SC-60 +

Hematology Analyzer

The Gold Standard


Technology
More Connectivity.

SC-60 +

60 samples per hour


20 parameters
CBC + 3 DIFF

Micro-sampling (10 µL)


Open tube

Only Two Reagents


Serachem Lyse (cyanide free reagent)
Serachem Diluent

Integrated work station


Large color touch-screen
Intuitive interface

Counting Block

Dilution Block

Open Tube
Serachem SC-60 +
Hematology Analyzer

SPECIFICATIONS SOFTWARE
Throughput*: 10.0” Color LED screen
OT: 60 samples/hour Operating system LINUX
Inverter card for LED screen
* Throughput performance is reachable in optimized conditions withan Touch screen technology
admittted margin for variation of 10%. With external mouse & keyboard
Sound Pressure Level: 58mm thermal printer with rapid paper loading
< 60 dBa Storage : 50000 samples with histograms & patient information
Operating Temperature & Humidity:
16 to 30°C (61 to 86°F) room temperature. PARAMETERS & PERFORMANCE DATA
Maximum relative humidity 85% for temperature up to 30°C (86°F)
20 Parameters:
Specimen Volume: WBC RBC MCH PLT
CBC + 3 part DIFF 10 µL and Pre dilution 20 µL LYM# & LYM% HGB MCHC MPV
Power Requirements: MID# & MID% HCT RDW PCT*
Power supply Adaptor Power Supply GRA# & GRA% MCV PDW* P-LCR P-LCC

Reagents: Linearity:
- Serachem Lyse Parameter Linearity Limit Visible Range
- Serachem Diluent WBC 0 - 100 x 103/mm 3 100 - 150 x 103/mm 3
- Serachem Cell Clean RBC 0 - 8 x 106/mm 3 8 - 18 x 106/mm 3
HGB 0 - 26 g/dL 26 - 30 g/dL
METHODS & TECHNOLOGIES HCT 0 - 80 % 80 - 90%
PLT (Whole blood) 0 - 2200 x 103/mm 3 2200 - 6000 x 103/mm 3
RBC/PLT Detection Principles PLT (PLT concentrate) 0 - 4000 x 103/mm 3 4000 - 6000 x 103/mm 3
Method Impedance
Precision:
Ruby diameter 70 µm
Depression of count 200 mb Parameters %CV Range
WBC <2. 0 4-10.0 x 103/µL
RBC < 1.5 4-7 x 106/µL
HGB <1.5 12-18 g/dl
HGB Measurement MCV <1.0 36-54%
Method Photometry PLT <4.0 200-500 x 103/µL
Wavelength 550 nm
Carry-over:
HCT Measurement WBC <2%
Method Numeric integration RBC <2%
HGB <2%
WBC Measurement
HCT <2%
Method Impedance
PLT <2%
Ruby diameter 100 µm
Depression of count 200 mb
* RUO parameters (Research Use Only)

3 Part Differentiation
Method Impedance + specific lyse action
MCV, MCH, MCHC, RDW, PCT*, PDW*
Calculation

SC-60 +

Imported & Mktd. in India by

SJK HEALTHCARE

#18/5, Near B. S. Heartcare Hospital, Pipli Road,


Mohan Nagar, Kurukshetra-136118 , Haryana
PH: +91-9416822111, 9468414009, 9468355009
E-Mail :sjkhealthcare@gmail.com